Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Medicine and Health Sciences

Isosorbide Mononitrate In Heart Failure With Preserved Ejection Fraction., Margaret M. Redfield, Kevin J. Anstrom, James A. Levine, Gabe A. Koepp, Barry A. Borlaug, Horng H. Chen, Martin M. Lewinter, Susan M. Joseph, Sanjiv J. Shah, Marc J. Semigran, G. Michael Felker, Robert T. Cole, Gordon R. Reeves, Ryan J. Tedford, W.H. Wilson Tang, Steven E. Mcnulty, Eric J. Velazquez, Monica R Shah, Eugene Braunwald Dec 2015

Isosorbide Mononitrate In Heart Failure With Preserved Ejection Fraction., Margaret M. Redfield, Kevin J. Anstrom, James A. Levine, Gabe A. Koepp, Barry A. Borlaug, Horng H. Chen, Martin M. Lewinter, Susan M. Joseph, Sanjiv J. Shah, Marc J. Semigran, G. Michael Felker, Robert T. Cole, Gordon R. Reeves, Ryan J. Tedford, W.H. Wilson Tang, Steven E. Mcnulty, Eric J. Velazquez, Monica R Shah, Eugene Braunwald

Division of Cardiology Faculty Papers

BACKGROUND: Nitrates are commonly prescribed to enhance activity tolerance in patients with heart failure and a preserved ejection fraction. We compared the effect of isosorbide mononitrate or placebo on daily activity in such patients.

METHODS: In this multicenter, double-blind, crossover study, 110 patients with heart failure and a preserved ejection fraction were randomly assigned to a 6-week dose-escalation regimen of isosorbide mononitrate (from 30 mg to 60 mg to 120 mg once daily) or placebo, with subsequent crossover to the other group for 6 weeks. The primary end point was the daily activity level, quantified as the average daily accelerometer …


Multivariate Criteria Most Accurately Distinguish Cardiac From Noncardiac Causes Of Dyspnea., Mirza Nubair Ahmad, Syed Hasan Yusuf, Rafath Ullah, Mirza Mujadil Ahmad, Mary K Ellis, Haroon Yousaf, Timothy E Paterick, Khawaja Afzal Ammar Dec 2015

Multivariate Criteria Most Accurately Distinguish Cardiac From Noncardiac Causes Of Dyspnea., Mirza Nubair Ahmad, Syed Hasan Yusuf, Rafath Ullah, Mirza Mujadil Ahmad, Mary K Ellis, Haroon Yousaf, Timothy E Paterick, Khawaja Afzal Ammar

The Texas Heart Institute Journal

Cardiopulmonary exercise testing provides oxygen pulse as a continuous measure of stroke volume, which is superior to other stress-testing methods in which systolic function is measured at baseline and at peak stress. However, the optimal peak oxygen pulse criterion for distinguishing cardiac from noncardiac causes of exercise limitation is unknown.

In comparing several peak oxygen pulse criteria against the clinical standard of cardiopulmonary exercise testing, we retrospectively studied 54 consecutive patients referred for cardiopulmonary exercise testing. These exercise tests included measurement of oxygen consumption, carbon dioxide production, breathing reserve, arterial blood gases at baseline and at peak stress, exercise electrocardiogram, …


Modified Maze Procedure For Atrial Fibrillation As An Adjunct To Elective Cardiac Surgery: Predictors Of Mid-Term Recurrence And Echocardiographic Follow-Up, Claudia Loardi, Francesco Alamanni, Fabrizio Veglia, Claudia Galli, Alessandro Parolari, Marco Zanobini Aug 2015

Modified Maze Procedure For Atrial Fibrillation As An Adjunct To Elective Cardiac Surgery: Predictors Of Mid-Term Recurrence And Echocardiographic Follow-Up, Claudia Loardi, Francesco Alamanni, Fabrizio Veglia, Claudia Galli, Alessandro Parolari, Marco Zanobini

The Texas Heart Institute Journal

The radiofrequency maze procedure achieves sinus rhythm in 45%–95% of patients treated for atrial fibrillation. This retrospective study evaluates mid-term results of the radiofrequency maze—performed concomitant to elective cardiac surgery—to determine sinus-rhythm predictive factors, and describes the evolution of patients' echocardiographic variables.

From 2003 through 2011, 247 patients (mean age, 64 ± 9.5 yr) with structural heart disease (79.3% mitral disease) and atrial fibrillation underwent a concomitant radiofrequency modified maze procedure. Patients were monitored by 24-hour Holter at 3, 6, 12, and 24 months, then annually. Eighty-four mitral-valve patients underwent regular echocardiographic follow-up. Univariate and multivariate analysis for risk factors …


The Reproducibility And Absolute Values Of Echocardiographic Measurements Of Left Ventricular Size And Function In Children Are Algorithm Dependent., Renee Margossian, Shan Chen, Lynn A. Sleeper, Lloyd Y. Tani, Girish S. Shirali, Fraser Golding, Elif Seda Selamet Tierney, Karen Altmann, Michael J. Campbell, Anita Szwast, Angela Sharkey, Elizabeth Radojewski, Steven D. Colan, Pediatric Heart Network Investigators May 2015

The Reproducibility And Absolute Values Of Echocardiographic Measurements Of Left Ventricular Size And Function In Children Are Algorithm Dependent., Renee Margossian, Shan Chen, Lynn A. Sleeper, Lloyd Y. Tani, Girish S. Shirali, Fraser Golding, Elif Seda Selamet Tierney, Karen Altmann, Michael J. Campbell, Anita Szwast, Angela Sharkey, Elizabeth Radojewski, Steven D. Colan, Pediatric Heart Network Investigators

Manuscripts, Articles, Book Chapters and Other Papers

BACKGROUND: Several quantification algorithms for measuring left ventricular (LV) size and function are used in clinical and research settings. The aims of this study were to investigate the effects of measurement algorithm and beat averaging on the reproducibility of measurements of the left ventricle and to assess the magnitude of agreement among the algorithms in children with dilated cardiomyopathy.

METHODS: Echocardiograms were obtained in 169 children from eight clinical centers. Inter- and intrareader reproducibility was assessed on measurements of LV volumes using the biplane Simpson, modified Simpson, and 5/6 × area × length (5/6AL) algorithms. Percentage error was calculated as …