Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 4 of 4
Full-Text Articles in Medicine and Health Sciences
Factors Impacting Echocardiographic Imaging After The Fontan Procedure: A Report From The Pediatric Heart Network Fontan Cross-Sectional Study., Richard V. Williams, Renee Margossian, Minmin Lu, Andrew M. Atz, Timothy J. Bradley, Michael Jay Campbell, Steven D. Colan, Dianne Gallagher, Wyman W. Lai, Gail D. Pearson, Ashwin Prakash, Girish S. Shirali, Meryl S. Cohen, Pediatric Heart Network Investigators
Factors Impacting Echocardiographic Imaging After The Fontan Procedure: A Report From The Pediatric Heart Network Fontan Cross-Sectional Study., Richard V. Williams, Renee Margossian, Minmin Lu, Andrew M. Atz, Timothy J. Bradley, Michael Jay Campbell, Steven D. Colan, Dianne Gallagher, Wyman W. Lai, Gail D. Pearson, Ashwin Prakash, Girish S. Shirali, Meryl S. Cohen, Pediatric Heart Network Investigators
Manuscripts, Articles, Book Chapters and Other Papers
Echocardiographic image quality in Fontan survivors may be limited by a variety of factors. We sought to describe echocardiographic quality and factors associated with study quality in subjects participating in the Pediatric Heart Network Fontan Cross-Sectional Study. Echocardiograms were obtained at 7 clinical sites using a standard protocol. Quality grading and analysis were performed by a core laboratory. Univariate and multivariable modeling were performed to assess factors associated with quality and ability to obtain images sufficient for prespecified quantitative analysis. A total of 543 echocardiograms were obtained. The quality of echocardiograms improved over the duration of the study. The great …
Early Echocardiographic Changes After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lydia King, Jodi Akin, Girish S. Shirali
Early Echocardiographic Changes After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lydia King, Jodi Akin, Girish S. Shirali
Manuscripts, Articles, Book Chapters and Other Papers
OBJECTIVES: To evaluate echocardiographic changes after SAPIEN valve implantation in the pulmonary position.
BACKGROUND: The feasibility of the SAPIEN transcatheter pulmonary valve (TPV) has recently been demonstrated. We evaluated changes in pulmonary valve function and the right ventricle after SAPIEN TPV placement.
METHODS: We evaluated echocardiograms at baseline, discharge, 1 and 6 months after TPV placement in 33 patients from 4 centers. Pulmonary insufficiency severity was graded 0-4. TPV peak and mean gradients were measured. Right ventricular (RV) size and function were quantified using routine measures derived from color, spectral, and tissue Doppler indices and two-dimensional echocardiography.
RESULTS: At baseline, …
Distribution Of Dyssynchrony In Subjects With No Known Cardiac Disease And Comparison Of Velocity Vector Imaging To Color-Coded Tissue Doppler Imaging., Anoop C Parameswaran, Bhaskar Purushottam, Aman Amanullah, Vincent M. Figueredo, M.D.
Distribution Of Dyssynchrony In Subjects With No Known Cardiac Disease And Comparison Of Velocity Vector Imaging To Color-Coded Tissue Doppler Imaging., Anoop C Parameswaran, Bhaskar Purushottam, Aman Amanullah, Vincent M. Figueredo, M.D.
Division of Cardiology Faculty Papers
Data on the distribution of dyssynchrony in subjects with normal ejection fraction (EF) and normal QRS are scarce. We studied 100 subjects with no known cardiac disease (52% male, mean age 60 ± 17 years) using velocity vector imaging (VVI). Seventeen percent had septal to lateral (S-L) wall longitudinal delay >75 msec, 63% of subjects had S-L wall radial delay >75 msec, and 25% had a circumferential opposing wall delay >100 msec. Those with circumferential opposing wall delay of >100 msec had a lower EF (57 ± 5% vs. 62 ± 5%, P < 0.05). In an additional group of 33 patients, we compared the longitudinal dyssynchrony parameters as assessed by VVI and tissue Doppler imaging (TDI) and found them to be comparable. In conclusion, we find significant variation in time to peak velocities in subjects with no known cardiac disease, who had a normal left ventricular ejection fraction and QRS duration. VVI is comparable to TDI.
Coronary Artery Diameter Related To Calcium Scores And Coronary Risk Factors As Measured With Multidetector Computed Tomography: A Substudy Of The Accuracy Trial, Yasmin S Hamirani, Khurram Nasir, Emil Avanes, Jigar Kadakia, Matthew J Budoff
Coronary Artery Diameter Related To Calcium Scores And Coronary Risk Factors As Measured With Multidetector Computed Tomography: A Substudy Of The Accuracy Trial, Yasmin S Hamirani, Khurram Nasir, Emil Avanes, Jigar Kadakia, Matthew J Budoff
The Texas Heart Institute Journal
Arterial remodeling, an early change of atherosclerosis, can cause dilated arterial diameter. We measured coronary artery diameter with use of noncontrast 64-slice multidetector computed tomography (MDCT), and studied its association with coronary artery calcium levels and traditional coronary risk factors.
We included 140 patients from the ACCURACY trial whose noncontrast MDCT images showed measurable coronary arteries. Using 3 measurements of left main coronary artery (LMCA) and right coronary artery (RCA) diameters within 3 mm of the ostium, we associated the results with traditional coronary risk factors and calcium scores.
The prevalence of LMCA and RCA calcium was 22% and 51%, …