Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Medicine and Health Sciences

Macrophage-Derived Netrin-1 Promotes Abdominal Aortic Aneurysm Formation By Activating Mmp3 In Vascular Smooth Muscle Cells, Tarik Hadi, Ludovic Boytard, Michele Silvestro, Dornazsadat Alebrahim, Samson Jacob, Jordyn Feinstein, Krista Barone, Wes Spiro, Susan Hutchison, Russell Simon, Debra L. Rateri, Florence Pinet, David Fenyo, Mark Adelman, Kathryn J. Moore, Holger K. Eltzschig, Alan Daugherty, Bhama Ramkhelawon Nov 2018

Macrophage-Derived Netrin-1 Promotes Abdominal Aortic Aneurysm Formation By Activating Mmp3 In Vascular Smooth Muscle Cells, Tarik Hadi, Ludovic Boytard, Michele Silvestro, Dornazsadat Alebrahim, Samson Jacob, Jordyn Feinstein, Krista Barone, Wes Spiro, Susan Hutchison, Russell Simon, Debra L. Rateri, Florence Pinet, David Fenyo, Mark Adelman, Kathryn J. Moore, Holger K. Eltzschig, Alan Daugherty, Bhama Ramkhelawon

Physiology Faculty Publications

Abdominal aortic aneurysms (AAA) are characterized by extensive extracellular matrix (ECM) fragmentation and inflammation. However, the mechanisms by which these events are coupled thereby fueling focal vascular damage are undefined. Here we report through single-cell RNA-sequencing of diseased aorta that the neuronal guidance cue netrin-1 can act at the interface of macrophage-driven injury and ECM degradation. Netrin-1 expression peaks in human and murine aneurysmal macrophages. Targeted deletion of netrin-1 in macrophages protects mice from developing AAA. Through its receptor neogenin-1, netrin-1 induces a robust intracellular calcium flux necessary for the transcriptional regulation and persistent catalytic activation of matrix metalloproteinase-3 (MMP3) …


Wearable Cardioverter-Defibrillator After Myocardial Infarction, Jeffrey E. Olgin, Mark J. Pletcher, Eric Vittinghoff, Jerzy Wranicz, Rajesh Malik, Daniel P. Morin, Steven Zweibel, Alfred E. Buxton, Claude S. Elayi, Eugene H. Chung, Eric Rashba, Martin Borggrefe, Trisha F Hue, Carol Maguire, Feng Lin, Joel A. Simon, Stephen Hulley, Byron K. Lee, Vest Investigators Sep 2018

Wearable Cardioverter-Defibrillator After Myocardial Infarction, Jeffrey E. Olgin, Mark J. Pletcher, Eric Vittinghoff, Jerzy Wranicz, Rajesh Malik, Daniel P. Morin, Steven Zweibel, Alfred E. Buxton, Claude S. Elayi, Eugene H. Chung, Eric Rashba, Martin Borggrefe, Trisha F Hue, Carol Maguire, Feng Lin, Joel A. Simon, Stephen Hulley, Byron K. Lee, Vest Investigators

Gill Heart & Vascular Institute Faculty Publications

BACKGROUND

Despite the high rate of sudden death after myocardial infarction among patients with a low ejection fraction, implantable cardioverter–defibrillators are contraindicated until 40 to 90 days after myocardial infarction. Whether a wearable cardioverter–defibrillator would reduce the incidence of sudden death during this high-risk period is unclear.

METHODS

We randomly assigned (in a 2:1 ratio) patients with acute myocardial infarction and an ejection fraction of 35% or less to receive a wearable cardioverter–defibrillator plus guideline-directed therapy (the device group) or to receive only guideline-directed therapy (the control group). The primary outcome was the composite of sudden death or death from …


Delayed Sternal Closure Does Not Reduce Complications Associated With Coagulopathy And Right Ventricular Failure After Left Ventricular Assist Device Implantation, Roh Yanagida, Navin Rajagopalan, Daniel L. Davenport, Thomas A. Tribble, Mark A. Bradley, Charles W. Hoopes Mar 2018

Delayed Sternal Closure Does Not Reduce Complications Associated With Coagulopathy And Right Ventricular Failure After Left Ventricular Assist Device Implantation, Roh Yanagida, Navin Rajagopalan, Daniel L. Davenport, Thomas A. Tribble, Mark A. Bradley, Charles W. Hoopes

Internal Medicine Faculty Publications

Delayed sternal closure (DSC) is occasionally adopted after implantation of left ventricular assist device (LVAD). Recent studies suggest that DSC be used for high risk group of patients with coagulopathy, hemodynamic instability or right ventricular failure. However, whether DSC is efficacious for bleeding complication or right ventricular failure is not known. This study is single center analysis of 52 patients, who underwent LVAD implantation. Of those 52 patients, 40 consecutive patients underwent DSC routinely. The sternum was left open with vacuum assist device after implantation of LVAD. Perioperative outcome of the patients who underwent routine DSC were compared with 12 …