Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 10 of 10

Full-Text Articles in Medicine and Health Sciences

Hemodynamic Goals In Shock Management: Is There One Target For All?, Maya Guglin Dec 2022

Hemodynamic Goals In Shock Management: Is There One Target For All?, Maya Guglin

Journal of Shock and Hemodynamics

The current guidelines for managing cardiogenic shock lack specificity and clarification. The main criterion for cardiogenic shock is low cardiac output, and the most important goal is to achieve adequate output from a shock state. Because of the complex nature of cardiogenic shock, a “one-size-fits-all" outline may not be the best solution. Historically, hemodynamic goals in cardiogenic shock are copied from septic shock. Because septic shock and cardiogenic shock are different hemodynamic entities, the goals should be different.


Hemodynamics And Kinetics Of Heart Failure With Preserved Ejection Fraction Shock, Yevgeniy Brailovsky, J. Eduardo Rame, Thierry Le Jemtel, Indranee Rajapreyar Dec 2022

Hemodynamics And Kinetics Of Heart Failure With Preserved Ejection Fraction Shock, Yevgeniy Brailovsky, J. Eduardo Rame, Thierry Le Jemtel, Indranee Rajapreyar

Journal of Shock and Hemodynamics

The classical paradigm of cardiogenic shock is severe impairment of left ventricular, right ventricular, or biventricular contractility resulting in decreased cardiac output and end-organ failure. In patients with preserved ejection fraction, cardiogenic shock results from impaired left ventricular filling leading to decreased cardiac output and end-organ hypoperfusion. Heart failure with preserved ejection fraction (HFpEF) comprises a heterogenous group of myocardial and systemic metabolic derangements. Cardiogenic shock with preserved left ventricular ejection is thought to be less common than with reduced left ventricular ejection fraction, and therapeutic approaches are not well standardized. We aim to review the pathophysiology of cardiogenic shock …


Role Of Invasive Hemodynamics In Shock Management: Is A Pulmonary Artery Catheter Always Necessary?, Ajay J. Kirtane Nov 2022

Role Of Invasive Hemodynamics In Shock Management: Is A Pulmonary Artery Catheter Always Necessary?, Ajay J. Kirtane

Journal of Shock and Hemodynamics

The pulmonary artery (PA) catheter can be a useful tool in the management of patients with cardiogenic shock; however, there are challenges with the use of this catheter, and clinicians must balance the risks and benefits. In addition, clinicians must properly interpret data generated from a PA catheter in the context of other data to optimize a patient's hemodynamics.


Diaphragmatic Function In Cardiovascular Disease: Jacc Review Topic Of The Week., Husam M Salah, Lee R Goldberg, Jeroen Molinger, G Michael Felker, Willard Applefeld, Tienush Rassaf, Ryan J Tedford, Michael Mirro Md, Facc, Fhrs, Faha, John G F Cleland, Marat Fudim Oct 2022

Diaphragmatic Function In Cardiovascular Disease: Jacc Review Topic Of The Week., Husam M Salah, Lee R Goldberg, Jeroen Molinger, G Michael Felker, Willard Applefeld, Tienush Rassaf, Ryan J Tedford, Michael Mirro Md, Facc, Fhrs, Faha, John G F Cleland, Marat Fudim

Parkview Heart Institute

In addition to the diaphragm's role as the primary respiratory muscle, it also plays an under-recognized role in cardiac function. It serves as a pump facilitating venous and lymph return, modulating left ventricular afterload hemodynamics and pericardial pressures, as well as regulating autonomic tone. Heart failure (HF) is associated with diaphragmatic changes (ie, muscle fiber atrophy and weakness, increased ratio of type I to type II muscle fibers, and altered muscle metaboreflex) that lead to diaphragmatic dysfunction with subsequent symptomatic manifestations of HF. Herein, it is proposed that targeting the diaphragm in patients with HF via inspiratory muscle training or …


Intra-Aortic Balloon Pump May Attenuate Adverse Hemodynamic Effects Of Negative Intrathoracic Pressure In Cardiogenic Shock, Faris Araj Sep 2022

Intra-Aortic Balloon Pump May Attenuate Adverse Hemodynamic Effects Of Negative Intrathoracic Pressure In Cardiogenic Shock, Faris Araj

The VAD Journal

High negative intrathoracic pressure (NIP), as occurs during obstructive sleep apnea or hiccups, results in adverse hemodynamic consequences, specifically a decrease in left ventricle (LV) performance. These untoward effects can potentially be catastrophic in the case of an already compromised LV in cardiogenic shock. The interplay of intra-aortic balloon pump counter pulsation during abrupt high NIP in cardiogenic shock is described.


Hemodynamic Variations In Cardiogenic Shock Phenotypes, Jason Katz Sep 2022

Hemodynamic Variations In Cardiogenic Shock Phenotypes, Jason Katz

Journal of Shock and Hemodynamics

Patients with cardiogenic shock are not all the same. They present with a variety of hemodynamic profiles and other features that may allow us to create specific phenotypes. It is possible that phenotyping these patients at presentation may then help us to identify the optimal and earliest therapies that will improve outcomes and, at the same time, help us to overcome some of the heterogeneity currently undermining clinical trials.


Use Of Impella Devices For Acute Cardiogenic Shock In The Perioperative Period Of Cardiac Surgery, Serge Sicouri, Vishal N Shah, Meghan Buckley, Nicholas Imperato, Jacqueline Mcgee, Elena Casanova, Eric Gnall, Konstadinos A Plestis Jul 2022

Use Of Impella Devices For Acute Cardiogenic Shock In The Perioperative Period Of Cardiac Surgery, Serge Sicouri, Vishal N Shah, Meghan Buckley, Nicholas Imperato, Jacqueline Mcgee, Elena Casanova, Eric Gnall, Konstadinos A Plestis

Division of Cardiology Faculty Papers

Introduction: The Impella ventricular support system is a device that can be inserted percutaneously or directly across the aortic valve to unload the left ventricle. The purpose of this study is to determine the role of Impella devices in patients with acute cardiogenic shock in the perioperative period of cardiac surgery.

Methods: A retrospective single-surgeon review of 11 consecutive patients who underwent placement of Impella devices in the perioperative period of cardiac surgery was performed. Patient records were evaluated for demographics, indications for placement, and postoperative outcomes.

Results: Impella devices were placed for refractory cardiogenic shock preoperatively in 6 patients, …


Pulsatility Is A Predictive Marker Of Improved Cardiac Function In Patients With Liquid Matrix-Treated Left Ventricular Assist Devices, Philemon Mikail, Rinku Skaria, Marvin Slepian, Janny Garcia, Richard Smith, Zain Khalpey Jul 2022

Pulsatility Is A Predictive Marker Of Improved Cardiac Function In Patients With Liquid Matrix-Treated Left Ventricular Assist Devices, Philemon Mikail, Rinku Skaria, Marvin Slepian, Janny Garcia, Richard Smith, Zain Khalpey

The VAD Journal

Objective: Left ventricular assist devices (LVADs) are utilized as a bridge to transplant or as destination therapy for patients with end-stage heart failure. Although cardiac offloading from these devices rarely leads to complete remodeling and functional recovery, the use of mesenchymal cells to modulate heart failure has been explored in recent years due to its intrinsic regenerative properties. Current methods of evaluating cardiac function have too much variability, difficulty of access, or require too frequent follow up to create universal weaning protocols. We hypothesized that the administration of amniotic allograft liquid matrix (LM) containing amnion-derived mesenchymal stem cells (aMSCs) in …


Decongestion Models And Metrics In Acute Heart Failure: Escape Data In The Age Of The Implantable Cardiac Pressure Monitor, David Paniagua, Glenn N Levine, Lorraine D Cornwell, Ernesto Jimenez, Biswajit Kar, Hani Jneid, Ali E Denktas, Tony S Ma Jul 2022

Decongestion Models And Metrics In Acute Heart Failure: Escape Data In The Age Of The Implantable Cardiac Pressure Monitor, David Paniagua, Glenn N Levine, Lorraine D Cornwell, Ernesto Jimenez, Biswajit Kar, Hani Jneid, Ali E Denktas, Tony S Ma

The Texas Heart Institute Journal

The United States Food and Drug Administration restricts the use of implantable cardiac pressure monitors to patients with New York Heart Association (NYHA) class III heart failure (HF). We investigated whether single-pressure monitoring could predict survival in HF patients as part of a model constructed using data from the ESCAPE (Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness) trial.

We validated survival models in 204 patients, using all-cause 180-day mortality. Two levels of model complexity were tested: 1) a simplified 1-pressure model based on pulmonary artery mean pressure ([PAM]1P) (information obtainable from an implanted intracardiac monitor alone), …


Modeling Of Patient-Specific Periaortic Mechanics And Pulmonary Artery Hemodynamics Based On Phase-Contrast Magnetic Resonance Imaging Sequences., Johane H. Bracamonte Jan 2022

Modeling Of Patient-Specific Periaortic Mechanics And Pulmonary Artery Hemodynamics Based On Phase-Contrast Magnetic Resonance Imaging Sequences., Johane H. Bracamonte

Theses and Dissertations

Inverse modeling in cardiovascular medicine is a collection of methodologies that can provide non-invasive patient-specific estimations of clinical risk factors using medical imaging as inputs. Its incorporation into clinical practice has the potential to improve diagnosis and treatment planning with low associated risks and costs.

Herein, three different phase contrast magnetic resonance imaging (MRI) modalities were implemented as input data, displacement encoding with stimulated echoes (DENSE MRI) applied, and time-resolved velocity encoding phase-contrast MRI, in 1D and 3D, applied to pulmonary artery (PA) hemodynamics.

A model to account for the effect of periaortic interactions due to static and dynamic structures …