Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 2 of 2
Full-Text Articles in Medicine and Health Sciences
The Reproducibility And Absolute Values Of Echocardiographic Measurements Of Left Ventricular Size And Function In Children Are Algorithm Dependent., Renee Margossian, Shan Chen, Lynn A. Sleeper, Lloyd Y. Tani, Girish S. Shirali, Fraser Golding, Elif Seda Selamet Tierney, Karen Altmann, Michael J. Campbell, Anita Szwast, Angela Sharkey, Elizabeth Radojewski, Steven D. Colan, Pediatric Heart Network Investigators
The Reproducibility And Absolute Values Of Echocardiographic Measurements Of Left Ventricular Size And Function In Children Are Algorithm Dependent., Renee Margossian, Shan Chen, Lynn A. Sleeper, Lloyd Y. Tani, Girish S. Shirali, Fraser Golding, Elif Seda Selamet Tierney, Karen Altmann, Michael J. Campbell, Anita Szwast, Angela Sharkey, Elizabeth Radojewski, Steven D. Colan, Pediatric Heart Network Investigators
Manuscripts, Articles, Book Chapters and Other Papers
BACKGROUND: Several quantification algorithms for measuring left ventricular (LV) size and function are used in clinical and research settings. The aims of this study were to investigate the effects of measurement algorithm and beat averaging on the reproducibility of measurements of the left ventricle and to assess the magnitude of agreement among the algorithms in children with dilated cardiomyopathy.
METHODS: Echocardiograms were obtained in 169 children from eight clinical centers. Inter- and intrareader reproducibility was assessed on measurements of LV volumes using the biplane Simpson, modified Simpson, and 5/6 × area × length (5/6AL) algorithms. Percentage error was calculated as …
Changes In Speckle Tracking Echocardiography Measures Of Ventricular Function After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John F. Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lazar Mandinov, Jason Buckley, Nicholas P. Pietris, Girish S. Shirali
Changes In Speckle Tracking Echocardiography Measures Of Ventricular Function After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John F. Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lazar Mandinov, Jason Buckley, Nicholas P. Pietris, Girish S. Shirali
Manuscripts, Articles, Book Chapters and Other Papers
BACKGROUND: Patients with free pulmonary regurgitation or mixed pulmonary stenosis and regurgitation and severely dilated right ventricles (RV) show little improvement in ventricular function after pulmonary valve replacement when assessed by traditional echocardiographic markers. We evaluated changes in right and left ventricular (LV) function using speckle tracking echocardiography in patients after SAPIEN transcatheter pulmonary valve (TPV) placement.
METHODS: Echocardiograms were evaluated at baseline, discharge, 1 and 6 months after TPV placement in 24 patients from 4 centers. Speckle tracking measures of function included peak longitudinal strain, strain rate, and early diastolic strain rate. RV fractional area change, tricuspid annular plane …