Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Analytical, Diagnostic and Therapeutic Techniques and Equipment

Manuscripts, Articles, Book Chapters and Other Papers

Pediatric

Publication Year

Articles 1 - 3 of 3

Full-Text Articles in Medicine and Health Sciences

Pediatric Nasogastric Tube Placement And Verification: Best Practice Recommendations From The Novel Project., Sharon Y. Irving, Gina Rempel, Beth Lyman, Wednesday Marie A Sevilla, Ladonna Northington, Peggi Guenter, American Society For Parenteral And Enteral Nutrition Dec 2018

Pediatric Nasogastric Tube Placement And Verification: Best Practice Recommendations From The Novel Project., Sharon Y. Irving, Gina Rempel, Beth Lyman, Wednesday Marie A Sevilla, Ladonna Northington, Peggi Guenter, American Society For Parenteral And Enteral Nutrition

Manuscripts, Articles, Book Chapters and Other Papers

The placement of a nasogastric tube (NGT) in a pediatric patient is a common practice that is generally perceived as a benign bedside procedure. There is potential risk for NGT misplacement with each insertion. A misplaced NGT compromises patient safety, increasing the risk for serious and even fatal complications. There is no standardized method for verification of the initial NGT placement or reverification assessment of NGT location prior to use. Measurement of the acidity or pH of the gastric aspirate is the most frequently used evidence-based method to verify NGT placement. The radiograph, when properly obtained and interpreted, is considered …


Echocardiographic Detection Of Increased Ventricular Diastolic Stiffness In Pediatric Heart Transplant Recipients: A Pilot Study., Shahryar M. Chowdhury, Ryan J. Butts, Anthony M. Hlavacek, Carolyn L. Taylor, Karen S. Chessa, Varsha M. Bandisode, Girish S. Shirali, Arni Nutting, G Hamilton Baker Mar 2018

Echocardiographic Detection Of Increased Ventricular Diastolic Stiffness In Pediatric Heart Transplant Recipients: A Pilot Study., Shahryar M. Chowdhury, Ryan J. Butts, Anthony M. Hlavacek, Carolyn L. Taylor, Karen S. Chessa, Varsha M. Bandisode, Girish S. Shirali, Arni Nutting, G Hamilton Baker

Manuscripts, Articles, Book Chapters and Other Papers

Background: Pediatric heart transplant recipients are at risk for increased left ventricular (LV) diastolic stiffness. However, the noninvasive evaluation of LV stiffness has remained elusive in this population. The objective of this study was to compare novel echocardiographic measures of LV diastolic stiffness versus gold-standard measures derived from pressure-volume loop (PVL) analysis in pediatric heart transplant recipients.

Methods: Patients undergoing left heart catheterization were prospectively enrolled. PVLs were obtained via conductance. The end-diastolic pressure-volume relationship was obtained via balloon occlusion. The stiffness constant, β, was calculated. Echocardiographic measures of diastolic function were derived from spectral and tissue Doppler and two-dimensional …


Validation Of Noninvasive Measures Of Left Ventricular Mechanics In Children: A Simultaneous Echocardiographic And Conductance Catheterization Study., Shahryar M. Chowdhury, Ryan J. Butts, Carolyn L. Taylor, Varsha M. Bandisode, Karen S. Chessa, Anthony M. Hlavacek, Girish S. Shirali, G Hamilton Baker Jul 2016

Validation Of Noninvasive Measures Of Left Ventricular Mechanics In Children: A Simultaneous Echocardiographic And Conductance Catheterization Study., Shahryar M. Chowdhury, Ryan J. Butts, Carolyn L. Taylor, Varsha M. Bandisode, Karen S. Chessa, Anthony M. Hlavacek, Girish S. Shirali, G Hamilton Baker

Manuscripts, Articles, Book Chapters and Other Papers

BACKGROUND: The accuracy of echocardiography in evaluating left ventricular contractility has not been validated in children. The objective of this study was to compare echocardiographic measures of contractility with those derived from pressure-volume loop (PVL) analysis in children.

METHODS: Patients with relatively normal loading conditions undergoing routine left heart catheterization were prospectively enrolled. PVLs were obtained via conductance catheters. The gold-standard measure of contractility, end-systolic elastance (Ees), was obtained via balloon occlusion of one or both vena cavae. Echocardiograms were performed immediately after PVL analysis under the same anesthetic conditions. Single-beat estimations of echocardiographic Ees were calculated using four different …