Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Analytical, Diagnostic and Therapeutic Techniques and Equipment

The Texas Medical Center Library

Phantom

Publication Year

Articles 1 - 4 of 4

Full-Text Articles in Medicine and Health Sciences

Characterization Of Treatment Planning System Photon Beam Modeling Errors In Iroc Houston Phantom Irradiations, Mallory Glenn Aug 2020

Characterization Of Treatment Planning System Photon Beam Modeling Errors In Iroc Houston Phantom Irradiations, Mallory Glenn

Dissertations & Theses (Open Access)

In radiation therapy, proper commissioning of the treatment planning system’s (TPS) dose calculation algorithm is critical because any errors in this process impact all treatment plans prepared in the system. Previously, TPS errors have been identified as a major cause for poor phantom irradiation performance, which may also mean that patients are treated suboptimally. The purpose of this work was to investigate the TPS beam modeling developed by the radiotherapy community to understand where inconsistencies may arise, which variables are most susceptible to variations, and in what way changing these variables can alter dose calculations.

Using the Imaging and Radiation …


An Automated Syringe Pump System For Improving The Reproducibility Of Dynamic Hyperpolarized Mri Phantoms, Harlee G. Harrison Aug 2016

An Automated Syringe Pump System For Improving The Reproducibility Of Dynamic Hyperpolarized Mri Phantoms, Harlee G. Harrison

Dissertations & Theses (Open Access)

AN AUTOMATED SYRINGE PUMP SYSTEM FOR IMPROVING THE REPRODUCIBILITY OF DYNAMIC HYPERPOLARIZED MRI PHANTOMS

Harlee Grace Harrison, B.S.

Advisory Professor: James Bankson, Ph.D.

Magnetic Resonance Imaging (MRI) is a powerful tool in the diagnosis of cancer due to its ability to provide good soft tissue contrast and image resolution without the use of ionizing radiation. The use of hyperpolarized pyruvate as a contrast agent for tumor metabolism during MR scans has the potential to provide information about tumor metabolism in vivo that is not available from traditional imaging measurements or any other method. Hyperpolarization is achieved through dynamic nuclear polarization. …


Assessment Of Uncertainty In Planning And Dose Delivery Of Proton Therapy In An Iroc- Houston Qa Phantom Due To Variable Ct Technique And Proton Energy, Mattie M. Mcinnis Aug 2015

Assessment Of Uncertainty In Planning And Dose Delivery Of Proton Therapy In An Iroc- Houston Qa Phantom Due To Variable Ct Technique And Proton Energy, Mattie M. Mcinnis

Dissertations & Theses (Open Access)

As proton therapy increases in popularity, so does the need for effective quality assurance. Proton therapy institutions participating in NCI funded clinical trials rely heavily on the credentialing and auditing services of IROC-H and therefore the process must be well understood. The purpose of this project is to understand the uncertainties in proton therapy treatment planning for the IROC-H proton phantom QA program due to variations in CT technique and proton energy. It was hypothesized that variations in CT technique and proton energy will alter the delivered dose distributions of typical proton treatments by reducing the percent of passing pixels …


The Development And Implementation Of An Anthropomorphic Head Phantom For The Assessment Of Proton Therapy Treatment Procedures, Paige A. Summers Aug 2011

The Development And Implementation Of An Anthropomorphic Head Phantom For The Assessment Of Proton Therapy Treatment Procedures, Paige A. Summers

Dissertations & Theses (Open Access)

Proton therapy has become an increasingly more common method of radiation therapy, with the dose sparing to distal tissue making it an appealing option, particularly for treatment of brain tumors. This study sought to develop a head phantom for the Radiological Physics Center (RPC), the first to be used for credentialing of institutions wishing to participate in clinical trials involving brain tumor treatment of proton therapy. It was hypothesized that a head phantom could be created for the evaluation of proton therapy treatment procedures (treatment simulation, planning, and delivery) to assure agreement between the measured dose and calculated dose within …