Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Keyword
-
- Anterior shoulder instability (1)
- Apprehension (1)
- Art (1)
- Detector presampling MTF (1)
- Dislocation (1)
-
- Excessive looseness (1)
- Healthcare environment (1)
- High-resolution CT (1)
- Infrared imaging (1)
- Light image (1)
- Lighting (1)
- MTF evaluation (1)
- Measurement (1)
- Melanoma -- Diagnosis (1)
- Patient stress (1)
- Phlebotomy (1)
- Positive distraction (1)
- Reconstruction MTF (1)
- Relocation (1)
- Self-Injury (1)
- Socket (1)
- Spatial resolution (1)
- Ultrasound imaging (1)
- VRX CT scanner (1)
- VRX detector (1)
- Vein (1)
- Vein contrast (1)
- VeinViewer (1)
Articles 1 - 11 of 11
Full-Text Articles in Medicine and Health Sciences
Light Image Therapy In The Health Care Environment., Anna Rae Dutro
Light Image Therapy In The Health Care Environment., Anna Rae Dutro
Electronic Theses and Dissertations
Use of positive distraction in the built healthcare environment to assist in alleviating stress in a patient was investigated. A backlit light image was mounted in the ceiling of an examination room to create a positive distraction for patients in the ETSU Pediatric Clinic in Johnson City, TN. Survey instruments were used to collect sample data from patients and physicians in a randomized, balanced controlled study designed to determine if patients experienced less stress in the room with the backlit image as compared to other rooms (treatments). Although a statistical difference was not determined between the room with the backlit …
Theoretical And Experimental Evaluation Of Spatial Resolution In A Variable Resolution X-Ray Computed Tomography Scanner, Roman Melnyk
Theoretical And Experimental Evaluation Of Spatial Resolution In A Variable Resolution X-Ray Computed Tomography Scanner, Roman Melnyk
Theses and Dissertations (ETD)
A variable resolution x-ray (VRX) computed tomography (CT) scanner can image objects of various sizes with greatly improved spatial resolution. The scanner employs an angulated discrete detector and achieves the resolution boost by matching the detector angulation to the scanner field of view (FOV) determined by the size of an object being imaged. A comprehensive evaluation of spatial resolution in an experimental version of the VRX CT scanner is presented in this dissertation. Two components of this resolution were evaluated – the pre-reconstruction spatial resolution, described by the detector presampling modulation transfer function (MTF), and the post-reconstruction spatial resolution, given …
Is Electrical Stimulation A Predictive Tool For Autonomic Dysfunction In Males With Diabetes?, Susan Dorothy Rand
Is Electrical Stimulation A Predictive Tool For Autonomic Dysfunction In Males With Diabetes?, Susan Dorothy Rand
Loma Linda University Electronic Theses, Dissertations & Projects
The purpose of this study was to examine whether electrical stimulation can be used as a predictive tool to assess autonomic dysfunction in males with diabetes. The study was designed to better understand the extent of autonomic nervous system (ANS) dysfunction in the diabetic population.
Controls and patients with diabetes were recruited from the community at large and the Loma Linda University Diabetes Treatment Center and were managed by a physician. Twelve (12) people with diabetes and thirteen (13) control subjects participated. Mean age (years) for people with diabetes was 52.4 +/- 6.1 and 47.2 +/-11.1 for controls (p =0.05). …
The Development Of The Self-Injury Self-Report Measure., Sonia Lorraine Coney
The Development Of The Self-Injury Self-Report Measure., Sonia Lorraine Coney
Electronic Theses and Dissertations
Despite the amount of research that has been conducted on self-injury there is a lack of empirically validated instruments with which to measure self-injurious behavior. The present study developed a measure to examine self-injury and the associated features. Undergraduate students (n = 184) were administered a set of surveys to assess demographics, self-injurious behavior, suicidal ideation, Axis I and Axis II disorders, and impulsivity. Results indicated that a reliable measure, able to assess the extent of self-injury as well as associated features, was developed. Such a measure will enable clinicians to better assess self-injury and enable researchers to more fully …
Detection Of Simulated Apical Root Resorption Using Three Cone Beam Ct Machines, Marcus Paulson
Detection Of Simulated Apical Root Resorption Using Three Cone Beam Ct Machines, Marcus Paulson
Loma Linda University Electronic Theses, Dissertations & Projects
The purpose of this study was to determine orthodontists' ability to discriminate small differences of simulated apical root resorption (SARR) on extracted teeth, using the output from three cone beam computed tomography (CBCT) machines. Twenty-four unrestored maxillary anterior teeth exhibiting normal morphology, were collected. The teeth were scanned by three CBCT machines: 1) the NewTom 3G (AFP imaging, USA), 2) the iCAT (Imaging Sciences, USA) 3) and the MicroCAT II (Siemens Medical, USA). Using a sandblaster the apical portion of each tooth was reduced in 0.5 mm increments up to a total reduction of 1.5 mm. Each root modification was …
Comparison Of Laser And Phosphoric Acid Etching On Sealant Shear Bond Strength, Seth David Latimer
Comparison Of Laser And Phosphoric Acid Etching On Sealant Shear Bond Strength, Seth David Latimer
Loma Linda University Electronic Theses, Dissertations & Projects
PURPOSE: To compare the effect of traditional phosphoric acid etching with Er,Cr:YSGG laser enamel etching on the shear bond strength of sealant material.
METHODS: Extracted healthy third molars were mounted in acrylic exposing the flattest surface available. Three groups of twenty teeth were used to evaluate traditional acid etching with 37% phosphoric acid as a control group as well as two different laser settings. The sealant material was attached using specialized jigs and then subjected to shear bond strength testing utilizing the ultradent method (MTS machine). Statistical methods employed were the Kruskal-Wallis rank test and the Mann-Whitney U test.
RESULTS: …
Depth And Size Limits For The Visibility Of Veins Using The Veinviewer Imaging System, Soujanya Ganesh
Depth And Size Limits For The Visibility Of Veins Using The Veinviewer Imaging System, Soujanya Ganesh
Theses and Dissertations (ETD)
Administration of fluids or medication and blood draw procedures require the nurse or the phlebotomist to access the veins in patients at hospitals or phlebotomy centers. It is important to minimize the discomfort associated with sticking needles in the patient more than once and most often, necessary to find an appropriate vein within few minutes. However, problems involved in accessing veins in pediatric and obese patients make it very difficult to perform a successful stick in a short time. The VeinViewer Imaging System is an infrared imaging device that provides the nurses and phlebotomists a means for locating veins in …
Biochemical Characteristics Of Inconsistent Free T₄ Assays, Kristofer S. Fritz
Biochemical Characteristics Of Inconsistent Free T₄ Assays, Kristofer S. Fritz
Loma Linda University Electronic Theses, Dissertations & Projects
Serum levels of free thyroxine (T4) are helpful in the clinical evaluation of patients who are suspected of having thyroid disease, since free T4 (unbound) is known to closely relate to hyper, eu and hypothyroidism. There are documented inconsistencies among commercially available direct free thyroxine immunoassays. The biochemical basis for these inconsistencies is not understood and has not been characterized. Direct free T4 measurements have been linked to both T4-binding serum protein concentrations and protein-bound T4 concentrations. A free T4 reference method using direct equilibrium dialysis radioimmunoassay has been well characterized. New …
Reproducibility Of Two Non-Consecutive Scans Using A Newtom 3g; In Vitro Model, Hyoung Jin Park
Reproducibility Of Two Non-Consecutive Scans Using A Newtom 3g; In Vitro Model, Hyoung Jin Park
Loma Linda University Electronic Theses, Dissertations & Projects
Purpose: The aim of this study was to evaluate the reproducibility of mineral density measurement expressed in Hounsfield Units (HU) using a phantom device with known mineral densities and the NewTom 3G Cone Beam Computerized Tomography (CBCT).
Materials and Methods: A phantom device made of 21 HA cylindrical disks with known densities was fabricated. The phantom was scanned in 6, 9, and 12 inch fields of view using a NewTom 3G CBCT. The scans were repeated at non-consecutive sessions. Volumetric data in each of the scans were formatted to DICOM images. HU values of the regions of interest were retrieved …
The Effectiveness Of Shoulder Injury Assessment Techniques: Analyzing The Occurrences Of False Positives, Alec Cianfichi
The Effectiveness Of Shoulder Injury Assessment Techniques: Analyzing The Occurrences Of False Positives, Alec Cianfichi
Undergraduate Theses and Capstone Projects
Shoulder injuries are very common in sports such as baseball, football, and tennis due to high impact and stress placed on the shoulder joint. Due to the greater chance of shoulder injuries in these types of sports, it is imperative for shoulder injury assessments to be accurate in order to ensure that the athlete does not participate with an injured shoulder or lose participation time due to an incorrect assessment. In order to assess the validity of the Apprehension, Relocation, and Surprise test for shoulder instability, student athletes with no known shoulder injuries were evaluated. Tests were conducted under the …
Development Of A Blood Test For The Detection Of Cutaneous Malignant Melanoma, Rebecca Slattery
Development Of A Blood Test For The Detection Of Cutaneous Malignant Melanoma, Rebecca Slattery
Theses : Honours
Cutaneous Malignant Melanoma is a highly aggressive form of skin cancer that has a tendency to metastasise. In its early stages, the 5-year survival rate of patients is greater than 90% following surgical excision of an in situ tumour. However, following metastasis of the tumour, the 5-year survival rate declines to 5-35%. Due to the correlation between metastasis and declining survival, studies have attempted to identify potential metastasis as early as possible. Molecular markers of melanoma cells in the peripheral blood of CMM patients have been investigated, as the invasion of tumour cells into the blood is one of the …