Open Access. Powered by Scholars. Published by Universities.®

Environmental Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 30 of 34

Full-Text Articles in Environmental Engineering

Wpływ Instalacji Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza, Robert Oleniacz May 2015

Wpływ Instalacji Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza, Robert Oleniacz

Robert Oleniacz

At the turn of 2015/2016 it is planned to launch in Poland a few new municipal solid waste incineration plants. This type activities causes usually concerns of the local community due to their potential negative impact on air quality. Are these fears are, however, justified? The article describes allowable air emissions for new waste incinerators, the actual emissions that occur from such installations, and the current state of knowledge about their impact on air pollution.English title: The impact of installations of municipal solid waste thermal treatment on air quality.


Zastosowanie Systemu Modeli Calmet/Calpuff O Wysokiej Rozdzielczości Do Oceny Wpływu Na Jakość Powietrza Spalarni Odpadów Komunalnych W Krakowie, Mateusz Rzeszutek, Robert Oleniacz Mar 2015

Zastosowanie Systemu Modeli Calmet/Calpuff O Wysokiej Rozdzielczości Do Oceny Wpływu Na Jakość Powietrza Spalarni Odpadów Komunalnych W Krakowie, Mateusz Rzeszutek, Robert Oleniacz

Robert Oleniacz

In this paper there was presented a comprehensive assessment of the impact on air for the Municipal Solid Waste Incineration (MSWI) plant in Krakow with the planned start of operation by the end of 2015. Construction of the plant started in autumn 2013 in the district of Nowa Huta in Krakow. Modeling of the spread of pollutants in ambient air was conducted using an advanced multi-layer cloud CALPUFF Gaussian model, whose algorithms include, among other things, diversity of terrain. Spatial data of land area in the admitted computational domain are obtained from digital terrain model Shuttle Radar Topography Mission (SRTM3) …


Impact Of The Municipal Solid Waste Incineration Plant In Warsaw On Air Quality, Robert Oleniacz Dec 2014

Impact Of The Municipal Solid Waste Incineration Plant In Warsaw On Air Quality, Robert Oleniacz

Robert Oleniacz

The only Polish municipal solid waste (MSW) incinerator has been operating within the Municipal Solid Waste Disposal Plant in Warsaw since 2000. In the paper selected results of the air quality impact assessment for this incinerator during an operating period of one year (2008) are presented. With respect to the incinerated waste amounts and emission levels, the analysed period can be considered typical for this facility. Assessment of the air quality impact was carried out by assessing air pollutant emissions in reference to the applicable emission limit values and by modeling atmospheric dispersion of these pollutants. It has been found …


Ocena Wpływu Nowo Budowanej Spalarni Odpadów Komunalnych W Krakowie Na Jakość Powietrza Z Wykorzystaniem Modelu Calmet/Calpuff, Mateusz Rzeszutek, Robert Oleniacz Jun 2014

Ocena Wpływu Nowo Budowanej Spalarni Odpadów Komunalnych W Krakowie Na Jakość Powietrza Z Wykorzystaniem Modelu Calmet/Calpuff, Mateusz Rzeszutek, Robert Oleniacz

Robert Oleniacz

The chapter presents the results of the evaluation the impact on air quality for the newly built Municipal Solid Waste Thermal Treatment Plant in Krakow (Poland) whose construction started in autumn 2013. Air pollution impact assessment was performed for air emissions adopted at the levels of emission limit values applicable for waste incineration. Modeling of air pollutant dispersion was carried out using the system of CALMET/CALPUFF models. For this purpose, the terrain elevation data from Shuttle Radar Topography Mission (SRTM3) and data of land use from Corine Land Cover 2006 (CLC 2006) were adopted with a resolution of about 100 …


Assessment Of The Impact Of Municipal Waste Incineration Plants On Air Quality And The Possibilities Of Its Reduction, Robert Oleniacz May 2014

Assessment Of The Impact Of Municipal Waste Incineration Plants On Air Quality And The Possibilities Of Its Reduction, Robert Oleniacz

Robert Oleniacz

The planned construction of new municipal waste incineration plants over the next few years in Poland results in protests of local communities, which arise mainly from fear of an increase in the air pollution in its vicinity. These protests extend the investment process and hinder the selection of incineration plant location, but on the other hand they necessitate the use of more efficient solutions to reduce their impact on the air quality.This paper characterizes the world's most widely used technology for municipal solid waste incineration (MSWI) and assesses the possible maximum impact on the air quality of an exemplary MSWI …


Wykorzystanie Atmosferycznego Modelu Dyspersji Calpuff Do Oceny Oddziaływania Na Jakość Powietrza Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych W Krakowie, Mateusz Rzeszutek, Robert Oleniacz Apr 2014

Wykorzystanie Atmosferycznego Modelu Dyspersji Calpuff Do Oceny Oddziaływania Na Jakość Powietrza Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych W Krakowie, Mateusz Rzeszutek, Robert Oleniacz

Robert Oleniacz

The aim of this study was to determine the influence of the planned Municipal Waste Thermal Treatment Plant in Krakow on air pollution. Air quality impact assessment was based on the current state of the legal formalities (including emission limit values for waste incineration plants) and the results of the air pollutant atmospheric dispersion modeling for one month period. In this study to calculate of air pollutant dispersion was used model system CALMET/CALPUFF. Using the CALMET model variables in time and space weather condition were calculated. CALPUFF model were performed to computing of propagation of air pollution. Analysis of the …


Zakład Termicznego Przekształcania Odpadów Komunalnych W Krakowie – Założenia Projektowe I Stan Realizacji Budowy, Mateusz Rzeszutek, Robert Oleniacz Nov 2013

Zakład Termicznego Przekształcania Odpadów Komunalnych W Krakowie – Założenia Projektowe I Stan Realizacji Budowy, Mateusz Rzeszutek, Robert Oleniacz

Robert Oleniacz

The aim of this paper is to discuss the design assumptions and to determine the current status of the construction of the Municipal Solid Waste Thermal Treatment Plant (ZTPOK) in Krakow with a capacity of 220 thousand tons per year. This plant, planned to be built by the end of 2015 years, will be an important element of municipal waste management system in the area of the Municipality of Krakow. ZTPOK in Krakow will consist of the following installations: two lines of municipal solid waste incinerators based on moving grate technology, an installation of chemical solidification and stabilization of fly …


Wpływ Zakładu Unieszkodliwiania Stałych Odpadów Komunalnych W Warszawie Na Jakość Powietrza, Robert Oleniacz, Jadwiga Antolak Nov 2010

Wpływ Zakładu Unieszkodliwiania Stałych Odpadów Komunalnych W Warszawie Na Jakość Powietrza, Robert Oleniacz, Jadwiga Antolak

Robert Oleniacz

The paper presents the results of air quality impact assessment carried out for the Municipal Solid Waste Disposal Plant in Warsaw. As part of the plant is working so far the only municipal solid waste incinerator in Poland. Following the evaluation, including data for the year 2008, it was found that it is a minor source of emissions to air and causes a slight air pollution. The highest maximum one-hour and annual average concentrations caused at ground level are many times lower than the respective reference (or permissible) values and background values for analyzed substances in the air. Increasing the …


Impact Of A Large Medical Waste Incinerator On Air Quality, Robert Oleniacz Dec 2009

Impact Of A Large Medical Waste Incinerator On Air Quality, Robert Oleniacz

Robert Oleniacz

In the paper, an assessment of the compliance with air emission limit values and the impact on air quality of one of the largest medical waste incinerators in Poland, with a total capacity of about 300 kg/h (two incineration lines) is presented. The assessment took the results of continuous and periodic measurements of emissions in the plant’s installation over a period of 12 months’ operation into account. For this period, a calculation was performed for the spread of air pollutants emitted by the two operating incineration lines. According to the analysis and calculations, the analysed medical waste incineration plant does …


Suchy System Oczyszczania Spalin Ze Spalania Odpadów Niebezpiecznych – Ocena Skuteczności Usuwania Substancji Gazowych I Możliwości Spełniania Standardów Emisyjnych, Robert Oleniacz Dec 2008

Suchy System Oczyszczania Spalin Ze Spalania Odpadów Niebezpiecznych – Ocena Skuteczności Usuwania Substancji Gazowych I Możliwości Spełniania Standardów Emisyjnych, Robert Oleniacz

Robert Oleniacz

The research object was a medical waste incineration plant with a flue-gas treatment system based on dry sorption agent injection to combustion gases before a high-efficiency particulate collector. A combustion system was consisted with the fluidized bed reactor (starved air gasifier) and the secondary combustion chamber. As the dry absorbent was used a mixture of high reactive hydrated lime and activated carbon. Activated carbon content in the mixture was 5-10 % by mass. The absorbent was injected in the minimal recommended amount (4-5 kg/h). Applied collector was a ceramic filter with total filtration area of 120 m2 and guaranteed outlet …


Ocena Skuteczności Działania Suchego Systemu Oczyszczania Spalin Ze Spalania Odpadów Medycznych Opartego Na Wtrysku Sorbentu Wapniowo-Węglowego, Robert Oleniacz Jan 2008

Ocena Skuteczności Działania Suchego Systemu Oczyszczania Spalin Ze Spalania Odpadów Medycznych Opartego Na Wtrysku Sorbentu Wapniowo-Węglowego, Robert Oleniacz

Robert Oleniacz

The research object was a medical waste incineration plant with a capacity of 150 kg per hour equipped with a flue gas treatment system based on dry sorption process using a lime-carbon reagent with adsorbent removing in high-efficiency particulate collector. As the dry sorption agent was used a mixture of high reactive hydrated lime and activated carbon injected to combustion gases by pneumatic feeder. Activated carbon content in the mixture was 5-10 % by mass. Applied collector was ceramic filter with total filtration area of 120 m2 and guaranteed outlet dust concentration under 5 mg/Nm3. Among others things the aims …


Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Dec 2007

Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

Construction of the Municipal Solid Waste Incineration (MSWI) plant is considered optimal in the Programme of Management of Solid Waste in Krakow as well as in proposed scenarios of Municipal Waste Management. Evaluation of impact of the incineration plant with a capacity of 255000 tons per year on air quality in Krakow is presented in this work. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results …


Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Oct 2007

Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

The work presents air quality impact assessment for the planned Municipal Solid Waste Incineration (MSWI) plant in Krakow with a established capacity of 255000 tons per year. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results for the one of the considered localization of the MSWI plant in Krakow (district of Nowa Huta) support the thesis that building the incineration plant of this size will not …


Wpływ Dużej Spalarni Odpadów Przemysłowych I Niebezpiecznych Na Jakość Powietrza, Robert Oleniacz, Lidia Rusztowicz Jan 2007

Wpływ Dużej Spalarni Odpadów Przemysłowych I Niebezpiecznych Na Jakość Powietrza, Robert Oleniacz, Lidia Rusztowicz

Robert Oleniacz

Waste incineration causes unavoidable pollutant emissions to atmosphere and thus negative impact on air quality, but scale of the influence is often exaggerated. In the paper computation results of the atmospheric dispersion of pollutants were presented for one of the largest industrial and hazardous waste incineration plant existing in Poland (processing capacity: 3 ton per hour). These results confirm the fact that the incinerator meets the requirements of best available techniques (BAT) for the waste incineration and its impact on air quality is relatively small. This effect is caused mainly by proper operation of the rotary kiln incinerator, high efficiency …


Analiza Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Jan 2007

Analiza Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

Construction of the Municipal Solid Waste Incineration (MSWI) plant is considered optimal in the Programme of Management of Solid Waste in Krakow as well as in proposed scenarios of Municipal Waste Management. Evaluation of impact of the incineration plant with a capacity of 255000 tons per year on air quality in Krakow is presented in this work. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results …


Ocena Oddziaływania Na Środowisko Instalacji Spalania Odpadów – Wybrane Problemy, Robert Oleniacz Oct 2005

Ocena Oddziaływania Na Środowisko Instalacji Spalania Odpadów – Wybrane Problemy, Robert Oleniacz

Robert Oleniacz

The paper presents some problems related to the environmental impact of waste incineration plants with particular emphasis on the impact on air quality and the assessment of this impact carried out for newly built incinerators. Methodology for the calculation of emissions for new plants based on emission standards was proposed. It has been shown that waste incineration plants complying with emission limit values to a negligible extent affect the air quality, especially in the case of units with small capacity.

In the case of polychlorinated dibenzo-p-dioxins and dibenzofurans, due to lack of permissible levels in the air, it was found …


Emisja Zanieczyszczeń Ze Spalania Odpadów Podestylacyjnych Z Produkcji Witaminy C W Piecu Fluidalnym, Robert Oleniacz Jan 2005

Emisja Zanieczyszczeń Ze Spalania Odpadów Podestylacyjnych Z Produkcji Witaminy C W Piecu Fluidalnym, Robert Oleniacz

Robert Oleniacz

Some results of continuous or periodical measurements of selected air pollutant concentrations and mass streams in the flue gases from liquid waste incineration in a fluidized bed incinerator were presented in the paper. During the researches distillation tails from vitamin C production, that is waste traces from regeneration such solvents as for example ethylene chloride, chloroform or trichloroethylene were incinerated. As a result of the researches there was determined optimal temperature of the fluidized bad in which the waste incineration should be carried out to minimization of CO and NOx formation. Required effectiveness of HCl removal from combustion gases to …


Metoda Oceny Trudności Oczyszczania I Toksyczności Spalin Powstających Podczas Spalania Odpadów, Robert Oleniacz Nov 2004

Metoda Oceny Trudności Oczyszczania I Toksyczności Spalin Powstających Podczas Spalania Odpadów, Robert Oleniacz

Robert Oleniacz

The paper presents a methodology for evaluating the cleaning difficulty and toxicity of combustion gases from waste incineration based on the knowledge of gases composition. This type of evaluation may be applicable to selection or modernization of flue gas cleaning systems for waste incineration plants and to comparative analy-sis of a pollution degree of raw (unclean) combustion gases. In the evaluation of the cleaning difficulty of gases six categories of difficulty have been identified for removal of selected substances or groups of substances. The evaluation is made individually for substances or groups of substances on condition their concentrations in flue …


Termiczne Przekształcanie Odpadów Medycznych W Instalacji Fluidalnej Firmy Seghers – Emisja Zanieczyszczeń Gazowych I Możliwości Jej Ograniczenia, Robert Oleniacz Jan 2003

Termiczne Przekształcanie Odpadów Medycznych W Instalacji Fluidalnej Firmy Seghers – Emisja Zanieczyszczeń Gazowych I Możliwości Jej Ograniczenia, Robert Oleniacz

Robert Oleniacz

The paper presents the results of measurements of concentrations and mass streams of selected components in the flue gases from the thermal treatment of medical waste in the Seghers incinerator based on fluidized bed reactor.

The tests were carried out at the measuring points located both before and after of the flue-gas cleaning system based on the injection of dry hydrated lime and carbon sorbent and a ceramic filter. In this way it was possible to determine the effectiveness of the removal of selected air pollutants in the dry cleaning system. Analysis of the results of measurements made ​​it possible …


Ocena Składu Gazów Odlotowych Z Procesów Spopielania Odpadów Niebezpiecznych Pod Kątem Trudności Oczyszczania I Toksyczności, Robert Oleniacz Dec 2001

Ocena Składu Gazów Odlotowych Z Procesów Spopielania Odpadów Niebezpiecznych Pod Kątem Trudności Oczyszczania I Toksyczności, Robert Oleniacz

Robert Oleniacz

Tightening of the European Union law in the field of the air emission limit values from waste incineration causes necessity for existing and new incineration plants to conform to the standards. It will often involve modernization of the flue gas cleaning system. Proposed in the paper the methodology of evaluation of the combustion gases composition in point of view cleaning difficulty should be useful to this end. Average toxicity factors for hazardous waste incineration flue gases were defined as well. Among other things they can be used in comparative analysis of the air pollutant concentration in the raw gas (before …


Czynniki Wpływające Na Skład Spalin I Wielkość Emisji Zanieczyszczeń Z Procesów Termicznego Przekształcania Odpadów Niebezpiecznych, Robert Oleniacz Oct 2001

Czynniki Wpływające Na Skład Spalin I Wielkość Emisji Zanieczyszczeń Z Procesów Termicznego Przekształcania Odpadów Niebezpiecznych, Robert Oleniacz

Robert Oleniacz

The work summarizes factors influencing on air emissions from various full-scale hazardous waste incinerators (rotary kiln, multiple hearth furnace, starved-air incinerator, fluidized bed incinerator, liquid injection incinerator). Air pollutant emissions from hazardous waste incineration can be minimized not only by flue-gas cleaning. There are many factors that influence on flue-gas composition and the quantity of air pollutants formed during incineration: the type, the composition and the quantity of waste, the way of waste introducing to the incinerator, excess air ratio, combustion temperature, retention time of exhaust gases etc. Special attention was paid to the loading of waste and incineration conditions …


Średni Współczynnik Toksyczności Spalin Emitowanych Z Procesów Spopielania Odpadów Niebezpiecznych, Robert Oleniacz Aug 2001

Średni Współczynnik Toksyczności Spalin Emitowanych Z Procesów Spopielania Odpadów Niebezpiecznych, Robert Oleniacz

Robert Oleniacz

The paper presents the characteristics of the Average Toxicity Factor (ATF) for combustion gases emitted from incineration of hazardous waste. Proposals for the interpretation of this factor and the possibility of its use in assessing the degree of nuisance of the process in terms of the level of air pollutant emissions were also discussed.

English title: Average toxicity factor of combustion gases emitted from hazardous waste incineration.


Spopielanie Odpadów Medycznych W Systemie Purotherm-Pyrolise – Zmienność Składu Spalin I Emisji Zanieczyszczeń W Cyklu Załadowczym, Robert Oleniacz, Marian Mazur, Marek Bogacki Jun 2000

Spopielanie Odpadów Medycznych W Systemie Purotherm-Pyrolise – Zmienność Składu Spalin I Emisji Zanieczyszczeń W Cyklu Załadowczym, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The paper presents selected effects of the cyclical nature of the two-stage process of medical waste incineration on the variation of concentrations of basic constituents and selected gaseous pollutants (NOx, CO, SO2, H2S and HCl) in flue gas discharged from the process. The study included the installation working in the Purotherm-Pyrolise system (waste gasification and gas afterburning) with actual yields of 100-150 kg/h. The phases of the process varied in dynamic and direction changes of the flue-gas composition and the levels of air pollutant emissions were separated and described for these phases. They can be very important for the organization …


Emisja Zanieczyszczeń Ze Spalania Odpadów Niebezpiecznych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki Jan 1998

Emisja Zanieczyszczeń Ze Spalania Odpadów Niebezpiecznych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The article presents measurement results of air pollutant emissions from incineration of selected hazardous wastes in a full-scale rotary kiln equipped with afterburner and a wet installation for flue gas cleaning. This type of kiln is suitable for thermal disposal of many sorts of wastes, both solid and liquid. Four groups of waste were being incinerated during the tests: coke tars, medical (hospital) and pharmaceutical wastes added to greased cleaning materials, a sawdust and used gloves, varnish and lubrication wastes, as well as waste rubber and resins. The study was performed in order to answer the question: is the process …


Emisja Metali Ciężkich Ze Spalania Odpadów Niebezpiecznych, Robert Oleniacz, Marian Mazur, Marek Bogacki Dec 1997

Emisja Metali Ciężkich Ze Spalania Odpadów Niebezpiecznych, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The paper presents the results of measurements of air emissions of heavy metals from hazardous waste incineration in a multiple hearth furnace and a rotary kiln incinerator equipped with a single wet flue gas cleaning systems. In the multiple hearth furnace an industrial sewage sludge (from coke industry) was being incinerated. In the rotary kiln such wastes were being incinerated as: waste paints, varnish and lubricant, coal tars waste, contaminated cleaning rags, sawdust and used gloves, waste resins and plastics, rubber waste, outdated pharmaceuticals and medicines, and hospital waste. The research allowed us to determine the levels of pollutant concentrations …


Emisja Zanieczyszczeń Podczas Składowania I Termicznej Utylizacji Osadów Ściekowych Z Przemysłu Koksochemicznego / Emissions During Storage And Thermal Utilization Of Sewage Sludge From Coke-Chemical Industry, Robert Oleniacz, Marian Mazur, Marek Bogacki Sep 1997

Emisja Zanieczyszczeń Podczas Składowania I Termicznej Utylizacji Osadów Ściekowych Z Przemysłu Koksochemicznego / Emissions During Storage And Thermal Utilization Of Sewage Sludge From Coke-Chemical Industry, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

Both storage and thermal disposal of sewage sludge from industrial wastewater treatment plants are a significant source of air pollutant emissions. The study included the sludge generated in the coke-chemical industry. The paper presents the results of measurements of emissions of selected substances during storage of the waste in a closed storage hall with natural ventilation and during incineration of the mechanically dewatered sludge in a multiple hearth furnace.


Spalanie Odpadów Poszpitalnych I Farmaceutycznych W Piecu Obrotowym / Incineration Of Hospital And Pharmaceutical Wastes In A Rotary Kiln Incinerator, Robert Oleniacz, Marian Mazur, Marek Bogacki Sep 1997

Spalanie Odpadów Poszpitalnych I Farmaceutycznych W Piecu Obrotowym / Incineration Of Hospital And Pharmaceutical Wastes In A Rotary Kiln Incinerator, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The paper presents selected results of research on hospital and pharmaceutical waste incineration in a full-scale rotary kiln with variable loads of the kiln. As part of these studies measurements of air pollutant concentrations in flue gases and leaching tests of solid combustion products were carried out. Based on these studies, the maximum dose of hospital and pharmaceutical waste was proposed in the mixture with industrial wastes, which does not cause excessive air emissions. The average emission factors for the waste mixture loading were also determined.


Spalarnia Odpadów Lobbe W Dąbrowie Górniczej, Marian Mazur, Robert Oleniacz, Ryszard Januszek Apr 1997

Spalarnia Odpadów Lobbe W Dąbrowie Górniczej, Marian Mazur, Robert Oleniacz, Ryszard Januszek

Robert Oleniacz

This paper is a general characteristic of the industrial and hazardous waste incineration plant which was operated in Dąbrowa Górnicza (Poland) in the 90. The waste incineration plant is based on two incinerators - a rotary kiln and a multiple hearth furnace. Levels of selected air pollutant emissions presented in the work allow to assess the potential impact of this facility on air quality.

English title: The LOBBE incineration plant in Dąbrowa Górnicza.


Emisja Zanieczyszczeń Ze Spalania Odpadów Ściekowych W Piecu Półkowym, Robert Oleniacz, Marian Mazur, Marek Bogacki Dec 1996

Emisja Zanieczyszczeń Ze Spalania Odpadów Ściekowych W Piecu Półkowym, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The article presents incineration tests of silty-tar sludge produced in the wastewater treatment plant for coke industry. Sewage sludges were incinerated in a full-scale multiple hearth incinerator equipped with a wet flue-gas cleaning system (alkaline scrubber). Measurements of air pollutant emissions were carried out both before and after the cleaning system. The obtained results allow to conclude that the thermal utilization of sewage sludge in this type of installation might be just a little cumbersome for the environment, using the appropriate equipment for the purification of exhaust gases. The paper also specifies minimum exhaust gas cleaning performance that guarantees compliance …


Badania Emisji Chlorowodoru I Związków Fluoru Podczas Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki Dec 1996

Badania Emisji Chlorowodoru I Związków Fluoru Podczas Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the results of measurements of the concentration of hydrogen chloride (HCl) and fluoride compounds (as HF) in raw and purified combustion gases discharged from the incineration of selected hazardous wastes. The study included two installations operating on an industrial scale: a multiple hearth furnace and a rotary kiln incinerator equipped with a single wet flue gas cleaning systems. In the multiple hearth furnace was being incinerated sludge from coke industry. In the rotary kiln were being incinerated coal (coke) tars, contaminated cleaning rags, sawdust, used gloves, outdated pharmaceuticals and medicines, hospital waste, waste paints, varnish and lubricant, …