Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Engineering

Modeling, Fabrication, And Optimization Of Niobium Cavities Final Phase: Final Report, Robert A. Schill Jr., Mohamed Trabia, William Culbreth Aug 2005

Modeling, Fabrication, And Optimization Of Niobium Cavities Final Phase: Final Report, Robert A. Schill Jr., Mohamed Trabia, William Culbreth

Transmutation Sciences Materials (TRP)

This final report provides the activities and accomplishments of Modeling, Fabrication, and Optimization of Niobium Cavities – Final Phase. The fluid flow experiments for the etching of the superconducting cavity walls and baffle designs of phase II of the three phases has been completed leading to a MS thesis in December of 2003. Designing the experimental setup of secondary electron emission was well underway in early summer of 2003 when funding was made available for this portion of the study. By March 2004, many of the components of the experimental study reached UNLV with some assembly accomplished. The first secondary …


Modeling, Fabrication, And Optimization Of Niobium Cavities: Phase Iii Fourth Quarterly Report, Robert A. Schill Jr., Mohamed Trabia, William Culbreth Apr 2005

Modeling, Fabrication, And Optimization Of Niobium Cavities: Phase Iii Fourth Quarterly Report, Robert A. Schill Jr., Mohamed Trabia, William Culbreth

Transmutation Sciences Materials (TRP)

Niobium cavities are important parts of the integrated NC/SC high-power linacs. Over the years, researchers in several countries have tested various cavity shapes. They concluded that elliptically shaped cells are the most appropriate shape for niobium superconducting cavities. The surface preparation can significantly affect the secondary electron emission yields. Such yields are used in design codes. Current codes use values obtained from niobium samples cleaned by a different means at temperatures other than the operating temperature. Secondary electron emission studies on LANL surface-cleaned niobium are conducted with preliminary data presented in this report at room temperature. Soon studies will be …


Developing A Sensing System For The Measurement Of Oxygen Concentration In Liquid Pb-Bi Eutectic: Quarterly Progress Report (Jan. 01 – March. 31, 2005), Yingtao Jiang, Bingmei Fu Mar 2005

Developing A Sensing System For The Measurement Of Oxygen Concentration In Liquid Pb-Bi Eutectic: Quarterly Progress Report (Jan. 01 – March. 31, 2005), Yingtao Jiang, Bingmei Fu

Transmutation Sciences Materials (TRP)

We performed data analysis on the data collected from LANL test loop. One student was been hired to perform the data analysis. A new proposal is submitted to TRP program. We have one paper accepted for publication in International Journal of Heat and Mass Transfer, and another paper accepted for oral presentation by IEEE International Symposium of Circuits and Systems for the track Chemical Sensors. A manuscript regarding to the RGA analysis for the calibration of oxygen sensor is on the way.


Modeling, Fabrication, And Optimization Of Niobium Cavities: Phase Iii, Third Quarterly Report, Robert A. Schill Jr., Mohamed Trabia, William Culbreth Jan 2005

Modeling, Fabrication, And Optimization Of Niobium Cavities: Phase Iii, Third Quarterly Report, Robert A. Schill Jr., Mohamed Trabia, William Culbreth

Transmutation Sciences Materials (TRP)

This quarterly report provides an update to the last phase of the Modeling, Fabrication, and Optimization of Niobium Cavities in the no-cost extension period. Designing the experimental setup of secondary electron emission was well underway in early summer of 2003 when funding was made available for this portion the study. By March 2004, many of the components of the experimental study reached UNLV with some assembly accomplished. The first secondary electron emission (SEE) measurement was made from the surface of a Faraday cup in September 2004. In December of 2005, the software for the particle positioning detector was finally up …


Modeling, Fabrication, And Optimization Of Niobium Cavities, Robert A. Schill Jr., Mohamed Trabia, William Culbreth Jan 2005

Modeling, Fabrication, And Optimization Of Niobium Cavities, Robert A. Schill Jr., Mohamed Trabia, William Culbreth

Transmutation Sciences Materials (TRP)

One of the key technologies for the deployment of accelerator driven transmutation systems is the accelerator itself. Elliptical superconducting niobium cavities are used to increase the efficiency of the high-power accelerators needed to support the transmutation mission.

One of the major sources of energy loss from a superconducting accelerator cavity is a process known as multiple impacting (or “multipacting”) of electrons. This phenomenon limits the maximum amount of energy and power that the niobium cavity can store. As a result, the maximum power available for accelerating the desired charge, as well as the overall performance of the accelerator is reduced. …


Developing A Sensing System For The Measurement Of Oxygen Concentration In Liquid Pb-Bi Eutectic, Yingtao Jiang, Bingmei Fu Jan 2005

Developing A Sensing System For The Measurement Of Oxygen Concentration In Liquid Pb-Bi Eutectic, Yingtao Jiang, Bingmei Fu

Transmutation Sciences Materials (TRP)

Although liquid lead-bismuth eutectic (LBE) is a good candidate for the coolant that can be employed in a subcritical transmutation blanket, it is known to be very corrosive to stainless steel, the material used in the containment structure. To mitigate this problem, trace levels of oxygen can be introduced into the system, causing the formation of a protective oxide layer at the interface between the LBE and steel. The proper formation of this oxide layer largely depends on the accurate measurement and subsequent control of the oxygen concentration in liquid LBE.

Yttria Stabilized Zirconia (YSZ) oxygen sensors, using molten bismuth …