Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Environmental Engineering

2007

Institution
Keyword
Publication
Publication Type

Articles 31 - 60 of 88

Full-Text Articles in Engineering

Utilization Of Thermopolastic Rejects With Different Reinforcing Elements In The Production Of Manhole Covers, Lama Mosad El Hatow Jun 2007

Utilization Of Thermopolastic Rejects With Different Reinforcing Elements In The Production Of Manhole Covers, Lama Mosad El Hatow

Archived Theses and Dissertations

This thesis aims to investigate the potential usage of rejected non-recyclable contaminated plastic rejects with different reinforcing elements to produce a viable product such as a manhole cover. Contaminated plastic rejects are generally deemed unrecyclable due to the cost and effort, including money, water, energy associated with cleaning the product in order to recycle it. By recycling these contaminated plastic rejects as is and reinforcing it with different reinforcing elements, we can enhance the mechanical properties of the material to enable it to be used as a viable, durable product such as a manhole cover. Problems associated with manhole covers …


Effectiveness Of Green Roof Stormwater Treatment Systems Irrigated With Recycled Green Roof Filtrate To Achieve Pollutant Removal With Peak And Volume Reduction In Florida, Martin Wanielista, Michael Hardin May 2007

Effectiveness Of Green Roof Stormwater Treatment Systems Irrigated With Recycled Green Roof Filtrate To Achieve Pollutant Removal With Peak And Volume Reduction In Florida, Martin Wanielista, Michael Hardin

BMP Trains Research and Publications

No abstract provided.


Subsidies For Energy Efficiency Improvements: Theory And Practice, Theodoros Zachariadis May 2007

Subsidies For Energy Efficiency Improvements: Theory And Practice, Theodoros Zachariadis

Theodoros Zachariadis

No abstract provided.


Characterization Of The Ibc Technologies Superlig¨ 620 Solid Phase Extraction Resin With Applications For Automated Process Monitoring, John Clements May 2007

Characterization Of The Ibc Technologies Superlig¨ 620 Solid Phase Extraction Resin With Applications For Automated Process Monitoring, John Clements

All Theses

Characterization of the IBC Advanced Technologies SuperLig¨ 620 solid phase extraction resin was performed in order to develop an automated strontium-90 process monitor. The main focus was on strontium separation from barium, with the goal of developing an automated separation process for strontium-90 in Hanford high-level tank wastes. High-level waste tanks contain significant cesium-137 activities, of which barium daughters are of great concern as interferences to strontium quantification. A number of complexants were studied in a series of batch distribution coefficient experiments, as SuperLig¨ 620 was not previously known to elute strontium in typical mineral acids. The optimal separation was …


Stormwater Effectiveness Of An Operating Green Roof Stormwater Treatment System And Comparison To Scaled Down Green Roof Stormwater Treatment System Chambers (2007), Martin Wanielista, Mike Hardin Apr 2007

Stormwater Effectiveness Of An Operating Green Roof Stormwater Treatment System And Comparison To Scaled Down Green Roof Stormwater Treatment System Chambers (2007), Martin Wanielista, Mike Hardin

BMP Trains Research and Publications

This report presents the results of a successful operating green roof in the state of Florida. The green roof is located on the Student Union building at the University of Central Florida. This green roof has thrived for more than two years hosting more than 50 tours educating architects, engineers, and policy makers on the many benefits green roofs provide.

Comparison of this full sized operating green roof stormwater treatment system with scaled down green roof stormwater treatment system chambers showed that the full size system can be described by the previously reported equivalent experimental chamber data. Thus the experimental …


Adsorption Of Lead (Ii) Ions By Organosilicate Nanoporous Materials, Larry Keith Isaacs Apr 2007

Adsorption Of Lead (Ii) Ions By Organosilicate Nanoporous Materials, Larry Keith Isaacs

Civil & Environmental Engineering Theses & Dissertations

As-synthesized organosilicate nanoporous (OSNP) materials HMS (hexagonal mesoporous structure) and MCM-41 were used as adsorbents for removal of lead (II) ions in laboratory batch and column studies. Mesoporous organosilicates were prepared from tetraethylorthosilicate (TEOS) and either an ionic (cetyltrimethyl-ammonium) or neutral (dodecylamine) surfactant. Batch reaction distribution coefficients for MCM-41 were KD = 51.5 L/g (SD = 26.3) at 24 h and KD = 73.7 L/g (SD = 40.5) at 7 d. OSNP lead (II) ion adsorption increased from pH = 3 until pH ca. 7.5 after which a sharp decrease in adsorption was noted. OSNP materials reflected a …


Modeling In Situ Bioremediation Of Perchlorate-Contaminated Groundwater, Roland E. Secody Mar 2007

Modeling In Situ Bioremediation Of Perchlorate-Contaminated Groundwater, Roland E. Secody

Theses and Dissertations

Perchlorate-contaminated groundwater is a significant problem for the Department of Defense and the United States Air Force. An innovative technology was recently developed which uses dual-screened treatment wells to mix an electron donor into perchlorate-contaminated groundwater in order to effect in situ bioremediation of the perchlorate by indigenous perchlorate reducing bacteria without the need to extract the contaminated water from the subsurface. In this study, a model that simulates operation of the technology is calibrated and validated using 761 days of observational data obtained from a field-scale technology evaluation project. A genetic algorithm was used with the first 113 days …


Biofiltration As A Viable Alternative For Air Pollution Control At Department Of Defense Surface Coating Facilities, David M. Hudock Mar 2007

Biofiltration As A Viable Alternative For Air Pollution Control At Department Of Defense Surface Coating Facilities, David M. Hudock

Theses and Dissertations

Surface coating operations at aircraft depot facilities are common throughout the Department of Defense (DoD). During paint application processes at Navy and Marine Corps Fleet Readiness Centers (FRCs), spray paints emit volatile organic compounds (VOCs) known to have harmful effects on human health and the environment. FRC East at Marine Corps Air Station Cherry Point, does not control the emissions of VOCs from any of its paint booths. The purpose of this research is to determine if FRC East and its surrounding area can benefit both economically and environmentally from a biofiltration system for air pollution control (APC) rather than …


Development Of A Screening Model For Design And Costing Of An Innovative Tailored Granular Activated Carbon Technology To Treat Perchlorate-Contaminated Water, William C. Powell Mar 2007

Development Of A Screening Model For Design And Costing Of An Innovative Tailored Granular Activated Carbon Technology To Treat Perchlorate-Contaminated Water, William C. Powell

Theses and Dissertations

Perchlorate contamination of drinking water is a problem that has recently gained national attention. The purpose of this research was to develop a tool to predict the cost and performance of tailored granular activated carbon (T-GAC), an innovative technology to treat perchlorate-contaminated water. The ability to predict cost and performance is essential to promote transfer and commercialization of innovative technologies. This study investigated how data obtained from small-scale laboratory tests could be applied to predict cost and performance of a full-scale T-GAC system to treat perchlorate-contaminated water. A technology model was developed using GAC design principles and using a multi-component …


The Effects Of Orthophosphate As A Copper Corrosion Control Inhibitor In High Alkalinity Drinking Water Systems, Stephen Grace Mar 2007

The Effects Of Orthophosphate As A Copper Corrosion Control Inhibitor In High Alkalinity Drinking Water Systems, Stephen Grace

Theses and Dissertations

The purpose of this research was to investigate orthophosphate as a corrosion inhibitor for copper pipe in a high-alkalinity drinking water system. Specifically, this thesis sought to answer three research questions regarding the impact of orthophosphate treatment, the nature of the mechanism by which orthophosphate controls copper corrosion, and the value of equilibrium modeling in predicting orthophosphate’s effects. The research questions were answered through a comprehensive literature review and experimental methodology integrating laboratory jar tests, water sampling and analysis from a field investigation, qualitative solids analysis, and equilibrium model application. This study analyzed field data obtained over the course of …


Characterization Of Chlorinated Ethene Degradation In A Vertical Flow Constructed Wetland, James M. Waldron Mar 2007

Characterization Of Chlorinated Ethene Degradation In A Vertical Flow Constructed Wetland, James M. Waldron

Theses and Dissertations

Chlorinated solvents, including perchloroethene (PCE) and trichlorethene (TCE), are among the most common groundwater contaminants found in the United States. Once released into the environment, chlorinated solvents are extremely persistent and often require costly and lengthy remedial actions. The use of constructed wetlands has shown promise as an effective and less costly alternative for the treatment of chlorinated solvent contaminated groundwater. This study characterized and evaluated the concentration of chlorinated ethenes within a vertical flow constructed wetland, fed with PCE contaminated groundwater, at Wright-Patterson Air Force Base (WPAFB), Ohio. Chlorinated ethene concentrations were characterized within three distinct layers of the …


Using Value-Focused Thinking To Evaluate The Use Of Innovative Stormwater Management Technologies On Air Force Installations, Jeffrey T. Falcone Mar 2007

Using Value-Focused Thinking To Evaluate The Use Of Innovative Stormwater Management Technologies On Air Force Installations, Jeffrey T. Falcone

Theses and Dissertations

Stormwater runoff occurs naturally after every storm event; however, traditional development practices have created many impervious surfaces, such as buildings, parking lots, and streets that increase runoff volume and flow rate. Conventional stormwater management practices focus on collecting runoff into centralized channels and conveying it as quickly as possible to local bodies of water. This type of conveyance system decreases the opportunity for stormwater to naturally infiltrate back into the ground. It also prevents contaminants from being naturally filtered out of stormwater flows. As a result, centralized conveyance systems can cause flooding, erosion, and terrestrial and aquatic habitat degradation. Innovative …


Basin-Scale Methodology For Evaluating Relative Impacts Of Pollution Source Abatement, James T. Mangarillo Feb 2007

Basin-Scale Methodology For Evaluating Relative Impacts Of Pollution Source Abatement, James T. Mangarillo

Environmental & Water Resources Engineering Masters Projects

The Blackstone River watershed covers an area of 475 me in central Massachusetts and northern Rhode Island. The Blackstone flows from its headwaters in the hills above Worcester, MA, through Woonsocket, RI and finally joins the Seekonk River in Pawtucket, RI. The Seekonk then flows into the Providence River on its way into Narragansett Bay. The historical significance of the Blackstone River has been recognized at the federal, state and local levels. Furthermore, the Blackstone is known to playa significant role on the hydrology and ecology of Narragansett Bay. This study is part of a larger study designed to evaluate …


Fractionation Of Natural Organic Matter In Nile Water To Reduce Disinfection By-Products Formation, Ahmed Abdul Aziz Al Qabany Feb 2007

Fractionation Of Natural Organic Matter In Nile Water To Reduce Disinfection By-Products Formation, Ahmed Abdul Aziz Al Qabany

Archived Theses and Dissertations

No abstract provided.


Lake Whatcom Model Calibration With Variable Stoichiometry In Sediments - Revised, Chris Berger, Scott A. Wells Feb 2007

Lake Whatcom Model Calibration With Variable Stoichiometry In Sediments - Revised, Chris Berger, Scott A. Wells

Civil and Environmental Engineering Faculty Publications and Presentations

This memorandum discusses model calibration and enhancements made to the Lake Whatcom water quality model. Model development and initial calibration were documented in the report “Lake Whatcom Water Quality Model” (Berger and Wells, 2005). The Lake Whatcom water quality model has been converted from CE-QUAL-W2 version 3.2 to version 3.5 (Cole and Wells, 2006).


Application Of Classical Versus Bayesian Statistical Methods To On-Line Radiological Monitoring, Amy Attardo Jan 2007

Application Of Classical Versus Bayesian Statistical Methods To On-Line Radiological Monitoring, Amy Attardo

All Theses

The on-line monitoring for illicit radioactive material with a minimum number of false detections is a critical need for homeland security. The primary objectives of this work were to apply both Bayesian and classical statistical process control chart techniques to the on-line monitoring of radiological data and to then compare the Type I and Type II error incidence rates. Two versions of the cumulative sum (CUSUM) and Shiryayev-Roberts (S-R) procedures known as total reset and alarm reset methods were developed. The best method in terms of Type I errors was the S-R total reset method. In terms of Type II …


Comparison Of Thm Formation During Disinfection: Ferrate Versus Free Chlorine For Different Source Waters, Adhem Mukattash Jan 2007

Comparison Of Thm Formation During Disinfection: Ferrate Versus Free Chlorine For Different Source Waters, Adhem Mukattash

Electronic Theses and Dissertations

The objective of the study was to compare the trihalomethanes (THMs) produced from ferrate with hypochlorite and to determine how different the THM production would be for a given degree of disinfection (3 log reduction in Heterotrophic Plate Count (HPC)). Different water samples were collected from Lake Claire, Atlantic Ocean, and secondary effluent from an advanced wastewater treatment plant. THM formation was determined using a standard assay over 7 days at room temperature. In addition samples were tested for Total Coliform Escherichia coli (TC/E.coli), and heterotrophic bacteria using HPC by spreadplating on R2A agar. Dissolved organic carbon (DOC) was measured …


Biostability In Drinking Water Distribution Systems In A Changing Water Quality Environment Using Corrosion Inhibitors, Bingjie Zhao Jan 2007

Biostability In Drinking Water Distribution Systems In A Changing Water Quality Environment Using Corrosion Inhibitors, Bingjie Zhao

Electronic Theses and Dissertations

In this study, the bacterial growth dynamics of 14 pilot drinking water distribution systems were studied in order to observe water quality changes due to corrosion inhibitor addition. Empirical models were developed to quantity the effect of inhibitor type and dose on bacterial growth (biofilm and bulk water). Water and pipe coupon samples were taken and examined during the experiments. The coupons were exposed to drinking water at approximately 20°C for at least 5 weeks to allow the formation of a measurable quasi- steady-state biofilm. Bulk water samples were taken every week. In this study, two simple but practical empirical …


Modeling Free Chlorine And Chloramine Decay In A Pilot Distribution System, Jorge Miguel Arevalo Jan 2007

Modeling Free Chlorine And Chloramine Decay In A Pilot Distribution System, Jorge Miguel Arevalo

Electronic Theses and Dissertations

The purpose of this study was to identify the effect that water quality, pipe material, pipe size, flow conditions and the use of corrosion inhibitors would have on the rate of free chlorine and chloramine decay in distribution systems. Empirical models were developed to predict the disinfectant residual concentration with time based on the parameters that affected it. Different water treatment processes were used to treat groundwater and surface water to obtain 7 types of finished waters with a wide range of water quality characteristics. The groundwater was treated either by conventional treatment by aeration (G1) or softening (G2) or …


Reviewing The Effects Of Alternative Fuels, Average Speed And Idling Time On Emissions From Orange County School Bus Fleet, Ali Bayat Jan 2007

Reviewing The Effects Of Alternative Fuels, Average Speed And Idling Time On Emissions From Orange County School Bus Fleet, Ali Bayat

Electronic Theses and Dissertations

Orange County, FL has been experiencing ozone concentrations in the past several years which in some cases exceeded the national and state standards. The high concentration of ground level ozone can cause a variety of health problems including chest pain, coughing, throat irritation, and congestion or it can worsen bronchitis, emphysema, and asthma. Other effects include reduction of agricultural crop and commercial forest yields, lower growth and survivability of tree seedlings, and higher susceptibility of plant to diseases, pests and other stresses such as harsh weather. The ozone generation rate is directly related to the ambient concentration of nitrogen oxides …


Quantification Of Emissions From Lawn And Garden Equipment In Central Florida, Megan Leigh Crum Jan 2007

Quantification Of Emissions From Lawn And Garden Equipment In Central Florida, Megan Leigh Crum

Electronic Theses and Dissertations

The objective of this study was to evaluate the practical limits of EPA's NONROAD 2005 to accurately simulate Central Florida conditions, especially with regard to lawn and garden equipment. In particular we investigated a NONROAD emission inventory using default inputs and then created a locally specific emission inventory. These emission inventories were prepared for Orange, Osceola, and Seminole county and focused only on the VOC and NOx emissions caused by lawn and garden equipment. The model was manipulated to assess its ability to represent this specific category of nonroad equipment for a given airshed first by running a base case …


Simulación Y Control De La Temperatura Dentro De Un Invernadero, Hernando Perez Rojas, Martín De Paul Cortes Jan 2007

Simulación Y Control De La Temperatura Dentro De Un Invernadero, Hernando Perez Rojas, Martín De Paul Cortes

Ingeniería en Automatización

El cambio de las condiciones atmosféricas durante los ciclos climáticos hace necesario utilizar invernaderos para proteger ciertos cultivos. Los invernaderos son estructuras cerradas en las que se mantienen microambientes que son adecuados para un buen desarrollo de las plantas. El control efectivo de algunas variables del clima dentro del invernadero es posible con la ayuda de modelos matemáticos. En este trabajo se presenta un modelo mejorado mediante una propuesta que incluye el efecto de la humedad sobre la temperatura dentro del invernadero. Esto puede considerarse como un avance en el diseño de modelos de clima de los invernaderos. Se presentan …


Nitrogen Oxides In The North Atlantic Troposphere: Impacts Of Boreal Wildfire And Anthropogenic Emissions, Maria Val Martin Jan 2007

Nitrogen Oxides In The North Atlantic Troposphere: Impacts Of Boreal Wildfire And Anthropogenic Emissions, Maria Val Martin

Dissertations, Master's Theses and Master's Reports - Open

Nitrogen oxides play a crucial role in the budget of tropospheric ozone (O sub(3)) and the formation of the hydroxyl radical. Anthropogenic activities and boreal wildfires are large sources of emissions in the atmosphere. However, the influence of the transport of these emissions on nitrogen oxides and O sub(3) levels at hemispheric scales is not well understood, in particular due to a lack of nitrogen oxides measurements in remote regions. In order to address these deficiencies, measurements of NO, NO sub(2) and NO sub(y) (total reactive nitrogen oxides) were made in the lower free troposphere (FT) over the central North …


Using Electrochemical Monitoring To Predict Metal Release In Drinking Water Distribution Systems, Rajendra D. Vaidya Jan 2007

Using Electrochemical Monitoring To Predict Metal Release In Drinking Water Distribution Systems, Rajendra D. Vaidya

Electronic Theses and Dissertations

Corrosion of distribution system piping and home plumbing materials is a major concern in the water community. Iron release adverse affects aesthetic water quality and the release of copper and lead is regulated by the Lead and Copper rule (LCR) and can adversely affect consumer health. Corrosion control is typically done by pH regulation and/or addition of corrosion inhibitors. Monitoring of corrosion control is typically done after the fact by monitoring metal release, functional group concentration of the selected chemical species or water quality. Hence, the associated laboratory analyses create a significant delay prior to the assessment of corrosion in …


Selected Lid Projects In New England, New England Environmental Finance Center Jan 2007

Selected Lid Projects In New England, New England Environmental Finance Center

Planning

Examples of low impact development (LID) projects in each state in New England.


Wpływ Dużej Spalarni Odpadów Przemysłowych I Niebezpiecznych Na Jakość Powietrza, Robert Oleniacz, Lidia Rusztowicz Jan 2007

Wpływ Dużej Spalarni Odpadów Przemysłowych I Niebezpiecznych Na Jakość Powietrza, Robert Oleniacz, Lidia Rusztowicz

Robert Oleniacz

Waste incineration causes unavoidable pollutant emissions to atmosphere and thus negative impact on air quality, but scale of the influence is often exaggerated. In the paper computation results of the atmospheric dispersion of pollutants were presented for one of the largest industrial and hazardous waste incineration plant existing in Poland (processing capacity: 3 ton per hour). These results confirm the fact that the incinerator meets the requirements of best available techniques (BAT) for the waste incineration and its impact on air quality is relatively small. This effect is caused mainly by proper operation of the rotary kiln incinerator, high efficiency …


Analiza Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Jan 2007

Analiza Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

Construction of the Municipal Solid Waste Incineration (MSWI) plant is considered optimal in the Programme of Management of Solid Waste in Krakow as well as in proposed scenarios of Municipal Waste Management. Evaluation of impact of the incineration plant with a capacity of 255000 tons per year on air quality in Krakow is presented in this work. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results …


Multivariate Analysis Of Groundwater And Soil Data From A Waste Disposal Site, Kevin G. Mumford, John F. Macgregor, Sarah E. Dickson, Richard H. Frappa Jan 2007

Multivariate Analysis Of Groundwater And Soil Data From A Waste Disposal Site, Kevin G. Mumford, John F. Macgregor, Sarah E. Dickson, Richard H. Frappa

Sarah E Dickson

Environmental site investigations often involve the collection and analysis of hundreds of samples producing data sets that contain thousands of data points, which are difficult and time consuming to analyze. Consequently, investigators often focus on key surrogate parameters for site characterization and remedial action planning and assessment, which results in a large portion of the data collected remaining unused. This study presents the application of principal component analysis (PCA) as an efficient statistical technique to examine large environmental data sets through highlighting patterns in a reduced-variable space. In this work, PCA was applied to ground water and soil data collected …


Assessing The Possibility Of Corrosion Occurrence In Metallic Stacks Caused By Hydrochloric Acid, João F. Gomes Jan 2007

Assessing The Possibility Of Corrosion Occurrence In Metallic Stacks Caused By Hydrochloric Acid, João F. Gomes

João F Gomes

This article presents a simple method to estimate the possibility of corrosion in metallic stacks and surfaces due to hydrochloric acid deposition from stack gases, based on the HCl content in gases and also the flue gas temperature


New Technologies For Effective Forest Fire Fighting, João Gomes Jan 2007

New Technologies For Effective Forest Fire Fighting, João Gomes

João F Gomes

Efficient fire extinction with water could be greatly improved by using superabsorbent polymers, added to the water used for fire fighting, or sprayed over surfaces of combustible materials in order to protect them from fire. Specially developed superabsorbent polymers such as acrylamide/2-acrylamide-2-methyl-propane-sulphonate (AA/AMPS) seem to be particularly efficient for this purpose. In terms of water absorption, the experimental tests performed, showed that the optimal composition of this polymer is 30:70 AMPS versus AA, using 0.5% of bis-acrylamide (BA) as crosslinking agent.