Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 30 of 217

Full-Text Articles in Entire DC Network

Effects Of Extraction Versus Non Extraction In Orthodontic Treatment On Buccal Corridor Ratio (Bcr), Emad Hussein, Sari Amer, Mohammad Abu Mowais, Nezar Watted, Stathis Effstathiou Jan 2024

Effects Of Extraction Versus Non Extraction In Orthodontic Treatment On Buccal Corridor Ratio (Bcr), Emad Hussein, Sari Amer, Mohammad Abu Mowais, Nezar Watted, Stathis Effstathiou

Journal of the Arab American University مجلة الجامعة العربية الامريكية للبحوث

Objective: To compare the influence of dental extractions to non-extraction orthodontic treatment on smile fullness and buccal corridor ratio (BCR).

Materials and Methods: 47 subjects from a university archive had pre- and post-treatment standardized extraoral diagnostic clinical photographs, randomly selected and distributed according to having undergone extractions (Group 1, n=24, 22 females and 2 males, mean age =20.5 ±5 years) pre-treatment, (Group 3, n=24, 22 females and 2 males, mean age =20.5 ±5 years) post treatment, or non-extraction (Group 2, n=23, 18 females and 5 males, mean age=20.9 ± 4 years) pre-treatment, (Group 4, n=23, 18 females and 5 males, …


Investigation Of The Dmft Index Of Type 2 Diabetes Mellitus Patients With A 5-Year Interval Cross Sectional Study, Oğuzhan Altun, Numan Dedeoğlu, Duygu Çelik Özen, Edanur Topaloğlu, Begüm Özemre Jan 2024

Investigation Of The Dmft Index Of Type 2 Diabetes Mellitus Patients With A 5-Year Interval Cross Sectional Study, Oğuzhan Altun, Numan Dedeoğlu, Duygu Çelik Özen, Edanur Topaloğlu, Begüm Özemre

Future Dental Journal

Aim: Type 2 diabetes mellitus (T2DM) is a chronic metabolic disease with insulin deficiency or dysfunction. Notably, T2DM also has clinical and radiological implications in the oral region. This study aims to evaluate the changes in decay, missed, and filled teeth (DMFT) indexes on panoramic radiographs of T2DM patients at the end of a five-year follow-up and compare them with the control group.

Materials and Methods: Two panoramic radiographs taken five years (mean 5.32±0.24) apart from each of the 92 patients (46 T2DM and 46 healthy) were evaluated. The DMFT index was calculated in a total of 184 panoramic …


Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, Diaa.Zahran@Fue.Edu.Eg, Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, A.Mohamed@Fue.Edu.Eg, Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, Salahhegazy2003@Yahoo.Com, Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, Ahmed.Abdelwahed@Fue.Edu.Eg Jan 2024

Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, Diaa.Zahran@Fue.Edu.Eg, Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, A.Mohamed@Fue.Edu.Eg, Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, Salahhegazy2003@Yahoo.Com, Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, Ahmed.Abdelwahed@Fue.Edu.Eg

Future Dental Journal

Aim this in vitro study was conducted to evaluate the effect of mechanical loading on different implant materials on supporting structures materials and methods: a total of three implant retained overdentures were used in this study, retained by two implants each (Titanium, polyetheretherketon and zirconia) were placed in epoxy resin casts at the canine area using a surgical guide. Soft liner material was used at the distal extension area to mimic the soft tissues. Two linear strain gauges were bonded buccal and lingual to each implant to measure the peri-implant strains during unilateral and bilateral loading. Results: during bilateral loading …


Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, Ahmed.Elghazally@Fue.Edu.Eg, Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, Bassem.Mohsen@Fue.Edu.Eg, Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, Amrelkhadem@Gmail.Com, Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, Hussen.Elsharkawi@Fue.Edu.Eg Jan 2024

Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, Ahmed.Elghazally@Fue.Edu.Eg, Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, Bassem.Mohsen@Fue.Edu.Eg, Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, Amrelkhadem@Gmail.Com, Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, Hussen.Elsharkawi@Fue.Edu.Eg

Future Dental Journal

Background: Several treatment options are planned for completely edentulous patients rehabilitation which were developed to meet patients desires and requirements, starting from conventional complete denture till implant supported fixed full arch cases. Each technique has its own indication and limitations. Passive fit is an important factor for the long-term success of implant- prosthesis, which necessitate accurate transfer of the implant position. Recently, digital impressions have been introduced in dental implant treatment. By the use of scan body and different optical scanning methods, the position of scan bodies can be transferred to a virtual implant position within the dental arch. Material …


Effect Of Concentrated Growth Factor Alone And Mixed With Hyaluronic Acid On Osseointegration Of Delayed Implant., Kholoud Sobhy Eldeeb Kholoud Eldeeb, Lobna Mohammed Abdelaziz, Shahira Elashiry, Eatemad Shoreibah Jan 2024

Effect Of Concentrated Growth Factor Alone And Mixed With Hyaluronic Acid On Osseointegration Of Delayed Implant., Kholoud Sobhy Eldeeb Kholoud Eldeeb, Lobna Mohammed Abdelaziz, Shahira Elashiry, Eatemad Shoreibah

Future Dental Journal

Purpose: The aim of current study was evaluating effect of concentrated growth factor alone and mixed with hyaluronic acid on osseointegration of delayed implant. Subject and Methods: A total of 12 patients, ranging in age from 20 to 45 years old, were divided into two groups in random manner. Group A: Dental implants were placed associating with concentrated growth factor. Group B: Dental implants were placed associating with concentrated growth factor and hyaluronic acid. Treatment changes were evaluated for each group and compared between groups. Results: In the mean of implant stability a statistically significant difference existed within group …


Effect Of Silver Diamine Fluoride On Micro-Tensile Bond Strength Of Composite To Dentin On Primary And Permanent Teeth, Dalia Yousry Ayoub B.D.Sc Faculty Of Dentistry, Sinai University,20173593@Fue.Edu.Eg, Osama Ibrahim El-Shahawy Professor Of Pediatric Dentistry And Dental Public Health, Faculty Of Oral And Dental Medicine, Future University In Egyp,Osama.Shahwy@Fue.Edu.Eg, Sara Ahmed Mahmoud .Professor Of Pediatric Dentistry And Dental Public Health Faculty Of Oral And Dental Medicine, Cairo University,Saraahmed@Dentistry.Cu.Edu.Eg, Eman Alaa Eldeen Abd Allah Associate Professor Of Pediatric Dentistry And Dental Public Health Faculty Of Oral And Dental Medicine, Future University In Egypt,Eman.Alaa@Fue.Edu.Eg Jan 2024

Effect Of Silver Diamine Fluoride On Micro-Tensile Bond Strength Of Composite To Dentin On Primary And Permanent Teeth, Dalia Yousry Ayoub B.D.Sc Faculty Of Dentistry, Sinai University,20173593@Fue.Edu.Eg, Osama Ibrahim El-Shahawy Professor Of Pediatric Dentistry And Dental Public Health, Faculty Of Oral And Dental Medicine, Future University In Egyp,Osama.Shahwy@Fue.Edu.Eg, Sara Ahmed Mahmoud .Professor Of Pediatric Dentistry And Dental Public Health Faculty Of Oral And Dental Medicine, Cairo University,Saraahmed@Dentistry.Cu.Edu.Eg, Eman Alaa Eldeen Abd Allah Associate Professor Of Pediatric Dentistry And Dental Public Health Faculty Of Oral And Dental Medicine, Future University In Egypt,Eman.Alaa@Fue.Edu.Eg

Future Dental Journal

Aim of the Study: The aim of the current study was to investigate the effect of silver diamine fluoride on micro-tensile bond strength of composite to dentin and on the bonding mechanism of dentin surface on primary and permanent teeth. Material and methods: This study included two groups: group 1 included twenty-four primary molars and group 2 included twenty-four premolars. Each group was further subdivided equally into sub-group A and sub-group B. Sub-groups A of each group were treated with a self-etch bonding system and 4-mm thick buildups of composite were placed with increments limited to 1 mm. Subgroups B …


The Reliability Of Soft Tissue Profile Analysis Comparing Photoshop And Cephalometric Measurements In Maxillary Protrusion Patients, Sara Usama Imam, Heba Dehis, Nagwa Elmangoury, Amr El-Beialy Jan 2024

The Reliability Of Soft Tissue Profile Analysis Comparing Photoshop And Cephalometric Measurements In Maxillary Protrusion Patients, Sara Usama Imam, Heba Dehis, Nagwa Elmangoury, Amr El-Beialy

Future Dental Journal

Abstract

Introduction: Cephalometric x-ray is considered as a crucial step in orthodontic diagnosis and treatment planning. However, patients nowadays, especially those pursuing cosmetic goals, are concerned about radiation dosages as a result of increased understanding. Therefore, the aim of this study is to provide a simple reliable, affordable and reproducible way to evaluate the soft tissue measures for creating an orthodontic treatment plan.

Methods: Comparing standardized profile photographs and lateral cephalograms were obtained from twenty-eight patients with maxillary protrusion of the age group between 14 – 24 years before and after retraction. Evaluation and comparison were done for cephalometric x-ray …


Evaluation Of Pain Perception Associated With Maxillary First Molars Distalization In The Presence Of Maxillary Third Molars Versus Extracted Third Molars Using Infra-Zygomatic Mini-Screws: A Randomized Clinical Trial, Nadeen H. Hafez, Yehya A. Mostafa, Amr E. El-Dakroury, Mostafa M. El-Dawlatly Jan 2024

Evaluation Of Pain Perception Associated With Maxillary First Molars Distalization In The Presence Of Maxillary Third Molars Versus Extracted Third Molars Using Infra-Zygomatic Mini-Screws: A Randomized Clinical Trial, Nadeen H. Hafez, Yehya A. Mostafa, Amr E. El-Dakroury, Mostafa M. El-Dawlatly

Future Dental Journal

Aim: The purpose of this randomized clinical trial was to compare the pain associated with distalizing maxillary first molars with the presence versus extraction of unerupted third molars using infra-zygomaic mini -screws in a group of adolescent female patients.

Study design: This randomized clinical trial (parallel group design) was approved by the Research Ethics Committee of the Faculty of Dentistry, Future University in Egypt

Materials and methods: 30 patients requiring bilateral maxillary molar distalization using infra-zygomatic mini-implant were randomly allocated to third molar extraction (TME) or third Molar presence (TMP) groups

All patients were asked to assess their pain levels …


Comparing Program Compatibility For Dental Operators Between Different In-Office Clear Aligners Software, Karim Ibrahim Hammam, Essam Nassef, Mostafa Al Dawltaly Jan 2024

Comparing Program Compatibility For Dental Operators Between Different In-Office Clear Aligners Software, Karim Ibrahim Hammam, Essam Nassef, Mostafa Al Dawltaly

Future Dental Journal

Aim: The aim of the present study was to compare program compatibility for dental operators between different in office clear aligners software: (3D Maestro,3shape, BlueSky bio, Plainmeca). Materials and methods: 4 in office clear aligners software: (3D Maestro,3shape, BlueSky bio, Plainmeca) were used. Ten orthodontists were recruited for the evaluation process, A total of 48 casts were used including upper and lower arches for each case. Each orthodontist made a check mark on each option in the pre-made scoring template.A check mark with YES was given a One point, and a check mark with NO was given Zero point. Results: …


Assessment Of External Apical Root Resorption Following En-Masse And Two Steps Retraction In Maxillary Protrusion Cases: A Randomized Controlled Clinical Trial, Aya Ahmed El Ashwal, Heba Mohamed Dehis, Faten Eid Jan 2024

Assessment Of External Apical Root Resorption Following En-Masse And Two Steps Retraction In Maxillary Protrusion Cases: A Randomized Controlled Clinical Trial, Aya Ahmed El Ashwal, Heba Mohamed Dehis, Faten Eid

Future Dental Journal

Aim: The aim of this study was to investigate the degree of external apical root resorption (EARR) following En-masse retraction (EM) and compared it to two steps retraction technique (TS) using friction mechanics.

Materials and Methods: Thirty adult female with maxillary protrusion were randomly allocated by a computer sequence generator with 1:1 allocation ratio. EM group (mean age = 17.7 ± 1.89 years) and TS group (mean age = 17.7 ± 1.77 years). Mini-screws were inserted followed by first premolars extraction then randomization was accomplished. Patients received treatment with either EM procedure or TS to close the extraction spaces after …


Oral Focal Mucinosis: A Case Report, Hala El-Kammar Dr, Yara Youssef, Bassant Mahmoud Moustafa, Iman M. Mostafa, Noha Adel Hassanine, Adham Fahmy, Rami Guiha Dr. Jan 2024

Oral Focal Mucinosis: A Case Report, Hala El-Kammar Dr, Yara Youssef, Bassant Mahmoud Moustafa, Iman M. Mostafa, Noha Adel Hassanine, Adham Fahmy, Rami Guiha Dr.

Future Dental Journal

Oral focal mucinosis is a rare lesion with less than 60 cases reported in English literature so far, to the best of our knowledge. It is considered to be the oral counterpart of cutaneous focal mucinosis and/or cutaneous myxoid cyst. Histopathologically, Oral focal mucinosis is demonsterates a well-circumscribed area of myxomatous connective tissue containing mucinous material, surrounded by denser collagenous connective tissue. We present a case of Oral focal mucinosis occurring on the buccal gingiva of the lower jaw.


Correlation Between Gingival Redness And Oral Health Related Quality Of Life In A Group Of Egyptian Children At New Giza University, Fayrouz Saber, Manal Ahmed Al Sayed, Ola Moustafa Omar Jan 2024

Correlation Between Gingival Redness And Oral Health Related Quality Of Life In A Group Of Egyptian Children At New Giza University, Fayrouz Saber, Manal Ahmed Al Sayed, Ola Moustafa Omar

Future Dental Journal

Introduction: The concept of oral health related quality of life (OHRQoL) is of great significance in the three areas of dental health, in particular the clinical practice of dentistry, research, and education. The reported prevalence of gingivitis in various developed countries is considered high. This rate escalates with the increase in age, especially around puberty. There is evidence that gingivitis is associated with the children’s OHRQoL as there are common risk factors between gingivitis’ of adolescence and their consequent OHRQoL.

Aim: This study aims to evaluate the correlation between gingival redness as evaluated by digital photographs and oral health related …


Evaluation Of Knowledge, Attitude And Practice Of Dental Interns About Using Antibiotics In Pediatric Dentistry, Ahmad Safwat Aied, Norhan Abd El-Wahab El-Dokky, Rania Abdallah Nasr Jan 2024

Evaluation Of Knowledge, Attitude And Practice Of Dental Interns About Using Antibiotics In Pediatric Dentistry, Ahmad Safwat Aied, Norhan Abd El-Wahab El-Dokky, Rania Abdallah Nasr

Future Dental Journal

Introduction: Antimicrobial resistance is one of the ten threats identified by the World Health Organization (WHO) in 2019, since it affects modern healthcare and the effective prevention and treatment of an ever-increasing range of infections. Recent estimates of the burden of antimicrobial resistance are very significant, with more than half a million cases of infection with selected antibiotic-resistant bacteria or new emerging resistant pathogens occurring in Europe; of note, data regarding antimicrobial resistance in low-income countries are largely unknown, increasing the overall risk of mortality, in particular in surgical procedures

Aim: The aim of the study was to evaluate the …


Implant Site Preparation Using Conventional Drilling Technique Versus Magnetic Malleting Technique (Randomized Clinical Study)., Tamer Bahaa Negidah, Ahmed Farid Shehab Prof, Hussein Hatem, Sara Zakaria Fanous, Mostafa Azab Jan 2024

Implant Site Preparation Using Conventional Drilling Technique Versus Magnetic Malleting Technique (Randomized Clinical Study)., Tamer Bahaa Negidah, Ahmed Farid Shehab Prof, Hussein Hatem, Sara Zakaria Fanous, Mostafa Azab

Future Dental Journal

Background The purpose of our current study is to determine whether using a Magnetic Mallet during oral and implant surgical procedures is more effective than using traditional instruments with regard to complication rate, tissue healing, and surgical results (primary stability and crestal bone loss). According to a number of writers, a Magnetic Mallet can be utilized for implant insertion, ridge expansion, sinus lifts, tooth extractions, and implant site preparation.

So, this study was conducted to ascertain whether using a Magnetic Mallet Throughout the process of oral and surgical implant operations is effective and to assume on whether it might help …


Stability Of Immediately Placed And Delayed Implants Using Resonance Frequency Analysis (Rfa). A Systematic Review, Sara H. Younis, Catherine I. Radana, Doha M. Galal, Heba K. Abdul-Fattah, John A. Labib Jan 2024

Stability Of Immediately Placed And Delayed Implants Using Resonance Frequency Analysis (Rfa). A Systematic Review, Sara H. Younis, Catherine I. Radana, Doha M. Galal, Heba K. Abdul-Fattah, John A. Labib

Future Dental Journal

Objectives: The aim of the present Systematic Review was to compare between immediate and delayed dental implant placement using resonance frequency analysis specifically Implant Stability Quotients (ISQ).

Search methods: Search was performed in two databases (PubMed and Cochrane Library) till March 2023. Randomized clinical trials (RCTs) were included and measurements of ISQ at time of placement and time of loading were recorded. We excluded papers discussing bone grafting, orthodontic treatment and implant surface treatment.

Results: Results were above ISQ threshold value of 65, with no significant difference between immediate and delayed implants. However, Immediate placement showed shorter treatment time and …


Comparative Evaluation Of Marginal Adaptation Of Two Sealers With Two Different Obturation Techniques Using Sem (An In Vitro Study), Nada Mohammady Shaheen, Wael Hussein Kamel, Ahmed Abdel Rahman Hashem, Mahmoud Mohamed Badr Jan 2024

Comparative Evaluation Of Marginal Adaptation Of Two Sealers With Two Different Obturation Techniques Using Sem (An In Vitro Study), Nada Mohammady Shaheen, Wael Hussein Kamel, Ahmed Abdel Rahman Hashem, Mahmoud Mohamed Badr

Future Dental Journal

Aim: The sealing ability of endodontic obturation plays a important role in long term prognosis of an endodontic treatment. Aim To evaluate and compare the marginal adaptation of epoxy resin-based sealer (AH Plus) versus Bioceramic-based sealer (Total fill BC Sealer) to root canals that obturated with two obturation techniques (Lateral condensation and single cone techniques) using scanning electron microscope (SEM). Materials and Methods Sixty recently extracted single rooted mandibular premolars teeth were disinfected. Access cavity preparation was performed followed by cleaning and shaping, using 2.6% NaOCl as final irrigation protocol. Teeth were then equally divided into 4 groups according to …


Accuracy And Trueness Of Exporting Computer Aided Designs Of 3-Unit Fixed Dental Prosthesis By 3 Cad Systems, Ezzat Abou-Alnaga, Ashraf Hussein, Ahmed Naguib, Shereen Ahmed Nossair Jul 2023

Accuracy And Trueness Of Exporting Computer Aided Designs Of 3-Unit Fixed Dental Prosthesis By 3 Cad Systems, Ezzat Abou-Alnaga, Ashraf Hussein, Ahmed Naguib, Shereen Ahmed Nossair

Future Dental Journal

Objectives: Computer-aided design (CAD) software programs offer the option to export 3D scans and designs across different CADCAM systems, commonly referred to as open CADCAM technology. However, there is insufficient evidence of whether this exporting procedure has an impact on the accuracy of digital designs.This study aimed to investigate the accuracy of exporting of computer aided designs (CAD) of three-unit fixed dental prosthesis using 3 CAD systems. Materials and Methods: Three CAD softwares (inLab 17™, CeraMill Mind™, Dental System 2017™) were used to generate designs of a three-unit fixed partial denture. The designs generated by each CAD software were exported …


Assessment Of The Effect Of Two Different Digital Fabrication Techniques On Marginal And Internal Fit Of Interim Fixed Dental Prothesis, Mohamed A. Shalaby, Mennatallah M. Wahba, Hisham I. Al-Ansari, Ahmed N. Mohamed Jun 2023

Assessment Of The Effect Of Two Different Digital Fabrication Techniques On Marginal And Internal Fit Of Interim Fixed Dental Prothesis, Mohamed A. Shalaby, Mennatallah M. Wahba, Hisham I. Al-Ansari, Ahmed N. Mohamed

Future Dental Journal

Aim: The aim of that study was to evaluate the marginal and internal fit of a 3-unit, and 6-unit interim fixed dental prosthesis manufactured through milling and 3D printing technologies. Materials and Methods: Forty-eight interim fixed dental prostheses (FDP) were equally divided into two groups according to the fabrication technique. In group (MT), specimens were fabricated through milling technology while in group (PT), specimens were obtained by 3D printing. Each group was subdivided equally according to the FDP span length into 3-unit FDP (SFDP), and 6-unit FDP (LFDP). Marginal and internal fit were measured through the superimposition of the digital …


Digital Fabrication Of Attachment For Implant-Anchored Auricular Prosthesis (Case Report)., Hussein El Charkawi Proffesor Jun 2023

Digital Fabrication Of Attachment For Implant-Anchored Auricular Prosthesis (Case Report)., Hussein El Charkawi Proffesor

Future Dental Journal

Aim: This novel technique, has adopted digital technology to fabricate a customized precision attachment for a patient who has lost his attachment which anchor his implant retained auricular prosthesis. A scanner was used to acquire the ball abutment’ geometry of craniofacial implant in the mastoid area. CAD/CAM technology and special software was used to fabricate a customized small PEEK precision attachment that was no longer available in the market. This attachment was picked-up by an auricular prosthesis. The retention qualities of the auricular prosthesis with this attachment was satisfactory for both the patient and the dentist. This novel approach will …


Prevalence Of Molar Incisor Hypomineralization In A Group Of Egyptian Children, Ayah Essam Almenawi B.D.S, Norhan Abd El-Wahab El-Dokky Professor Of Pediatric Dentistry & Dental Public Health, Soad Abdelmoniem Abdelmoniem Professor Of Pediatric And Dental Public Health Jun 2023

Prevalence Of Molar Incisor Hypomineralization In A Group Of Egyptian Children, Ayah Essam Almenawi B.D.S, Norhan Abd El-Wahab El-Dokky Professor Of Pediatric Dentistry & Dental Public Health, Soad Abdelmoniem Abdelmoniem Professor Of Pediatric And Dental Public Health

Future Dental Journal

Background: Molar incisor Hypomineralization (MIH) has become a more widespread problem around the world, while its prevalence in Egypt is underestimated with no data on its correlation to Hypomineralization of Second Primary Molars (HSPM). Aim: Estimate the prevalence of MIH and HSPM in Egypt, investigate the possibility of HSPM being a predictive factor for MIH, and the probable etiological factors for MIH. Material and Methods: Three hundred and seventeen healthy children aged seven to ten years old were dentally examined for Molar Incisor Hypomineralization and Hypomineralization of Second Primary Molars and all potentially correlated etiological factors. Both MIH and HSPM …


Evaluation Of Accuracy Of Intraoral Scanners Versus Extra Oral Scanners In Different Dental Arch Measurements, Mohamed Walid Saleh, 20143278@Fue.Edu.Eg , Future University In Egypt, Fouad Sharaby Fsharaby@Dentistry.Cu.Edu.Eg , Associate Professor Of Orthodontic Department Of Orthodontics Faculty Of Dentistry Cairo University, Essam Nassef Essam.Nasssef@Fue.Edu.Eg , Professor Of Orthodontic Department Of Orthodontics Faculty Of Oral And Dental Medicine Future University In Egypt Jun 2023

Evaluation Of Accuracy Of Intraoral Scanners Versus Extra Oral Scanners In Different Dental Arch Measurements, Mohamed Walid Saleh, 20143278@Fue.Edu.Eg , Future University In Egypt, Fouad Sharaby Fsharaby@Dentistry.Cu.Edu.Eg , Associate Professor Of Orthodontic Department Of Orthodontics Faculty Of Dentistry Cairo University, Essam Nassef Essam.Nasssef@Fue.Edu.Eg , Professor Of Orthodontic Department Of Orthodontics Faculty Of Oral And Dental Medicine Future University In Egypt

Future Dental Journal

Background: Orthodontics has been influenced by new technologies in many areas. There is a shift toward digitization of patient’s information and data. Aim: The aim of this study was to compare the accuracy of intraoral scanner and extra oral scanners using different dental arch measurements. Materials and Methods: The sample size consisted of 44 dental stone models for patients who finished orthodontic treatment. For each subject two digital models were made, one digital model obtained from extra oral scanner and one digital model obtained from Intra oral scanner. An external examiner measured intermolar width, intercanine width, mesiodistal width of the …


Changes In Lip Length And Strain After En-Masse Retraction With Maximum Anchorage In Female Patients With Bimaxillary Protrusion, Leena Shibl, Amr El-Beialy, Yehya Mostafa, Heba Dehis Jun 2023

Changes In Lip Length And Strain After En-Masse Retraction With Maximum Anchorage In Female Patients With Bimaxillary Protrusion, Leena Shibl, Amr El-Beialy, Yehya Mostafa, Heba Dehis

Future Dental Journal

Aim: The aim of the study is to evaluate the effect of en-masse retraction with maximum anchorage on the lip length, lip strain, and interlabial gap in adult female patients with bimaxillary protrusion. Materials and Methods: Thirteen patients underwent initial records including photographs, study casts, and cephalometric x-rays. En-masse retraction was performed using friction mechanics, with the use of temporary anchorage devices and power chains after the extraction of first premolars. The soft tissue was analyzed using lateral cephalometric radiographs before and after retraction. Results: The results showed that en-masse retraction had a significant effect on reducing lip strain, increasing …


Questionnaire Survey On Pain & Mini-Implant Failure In Class Ii Female Patients After Extraction Of Maxillary Second Molars Using Infra Zygomatic Mini Implants, Hosam Abdullah Zaza, Nagwa El Mangoury, Amr El Dakrory, Mostafa El Dawlatly Jun 2023

Questionnaire Survey On Pain & Mini-Implant Failure In Class Ii Female Patients After Extraction Of Maxillary Second Molars Using Infra Zygomatic Mini Implants, Hosam Abdullah Zaza, Nagwa El Mangoury, Amr El Dakrory, Mostafa El Dawlatly

Future Dental Journal

Background: Skeletal anchorage devices have been developed for case requiring absolute anchorage during orthodontic treatment. One of these anchorage devices is the Infra-zygomatic mini-implant type. However, the pain associated with this type of appliance have not been sufficiently evaluated from the patient’s point of view. Aim: The aim of this study was to survey patients for one week after insertion of the infra-zygomatic mini-implants and 1 week following every reactivation in order to evaluate their pain and discomfort as well as the percentage of mini-screw failure. Materials and methods: 10 patients requiring infra-zygomatic mini-implants were selected. All participants completed questionnaires …


Expression Of Vimentin, Α-Sma And Tgf-Β In Different Grades Of Oral Squamous Cell Carcinoma, Hala El-Kammar, Waleed F. Esmael, Nermeen S. Afifi Jun 2023

Expression Of Vimentin, Α-Sma And Tgf-Β In Different Grades Of Oral Squamous Cell Carcinoma, Hala El-Kammar, Waleed F. Esmael, Nermeen S. Afifi

Future Dental Journal

Abstract

Background: Oral Squamous cell carcinoma (OSCC) is typically discovered at an early stage; nevertheless, regional lymph node metastases are prevalent; therefore, surgical excision of the primary tumor is commonly coupled with neck dissection and radiotherapy. Cancer cells become invasive by acquiring a mesenchymal phenotype, a process known as the epithelial-to-mesenchymal transition. Vimentin, α-SMA and TGF-β expressions are believed to take part in EMT and tumor progression. Aim: this work aimed to evaluate the expression of Vimentin, α-SMA and TGF-β on OSCC progression and hence propose potential role as potential prognostic markers or therapeutic targets. Materials and methods: twenty-four specimens …


Assessment Of Crestal Bone Loss And Implant Stability Of Implant Drilling Protocol At Low Speed Without Irrigation Versus Conventional Drilling Protocol, Omar Elmeligy O. Elmeligy, Ahmed Farid Shehab, Sameh Mekhemer, Ahmed Abozekry Jun 2023

Assessment Of Crestal Bone Loss And Implant Stability Of Implant Drilling Protocol At Low Speed Without Irrigation Versus Conventional Drilling Protocol, Omar Elmeligy O. Elmeligy, Ahmed Farid Shehab, Sameh Mekhemer, Ahmed Abozekry

Future Dental Journal

Abstract

Aim: This study assesses crestal bone loss surrounding dental implants, primary and secondary stability in sites prepared by conventional versus low speed drilling protocol. Material and Methods: Ten patients received 20 implants to restore an edentulous area in the lower posterior mandibular area. Patients were blindly divided into a control and study group. In the control group, sequential drilling was performed at 1,200 rpm and torque of 30 Ncm with irrigation till reaching the planned length and diameter. In the Study group, sequential drilling was performed at 150 rpm and torque of 50 Ncm without irrigation till reaching …


Computer Guided Versus Conventional Maxillary Sinus Augmentation Using Allogenic Bone Blocks With Simultaneous Implant Placement In Severely Pneumatized Sinuses, Hisham G. Zulhemma Department Of Oral And Maxillofacial Surgery, Future University In Egypt, Egypt. 20172740@Fue.Edu.Eg, Waleed Ragab El-Beialy Professor Of Oral And Maxillofacial Surgery -Cairo University, Egypt. Wbeialy@Yahoo.Com, Ahmed Abd Elsamad Associate Professor Of Oral And Maxillofacial Radiology– Cairo University, Egypt. Abdalsamad_A@Yahoo.Com, Ahmed Abozekry Lecturer Of Oral And Maxillofacial Surgery –Future University In Egypt, Egypt. Ahmed.Kamal@Fue.Edu.Eg Jun 2023

Computer Guided Versus Conventional Maxillary Sinus Augmentation Using Allogenic Bone Blocks With Simultaneous Implant Placement In Severely Pneumatized Sinuses, Hisham G. Zulhemma Department Of Oral And Maxillofacial Surgery, Future University In Egypt, Egypt. 20172740@Fue.Edu.Eg, Waleed Ragab El-Beialy Professor Of Oral And Maxillofacial Surgery -Cairo University, Egypt. Wbeialy@Yahoo.Com, Ahmed Abd Elsamad Associate Professor Of Oral And Maxillofacial Radiology– Cairo University, Egypt. Abdalsamad_A@Yahoo.Com, Ahmed Abozekry Lecturer Of Oral And Maxillofacial Surgery –Future University In Egypt, Egypt. Ahmed.Kamal@Fue.Edu.Eg

Future Dental Journal

Background: Maxillary sinus lifting is a complex procedure with reported complications in the literature where the presence of sinus septa further complicates the procedure, they including membrane perforation, bleeding. Aim: The aim of this study is to decrease the incidence of membrane perforation which is the most common reported complication, and to determine whether the use of surgical guides could decrease the incidence of membrane perforation. Materials and methods: A total of 12 cases where blindly divided into 2 groups; Group (A) computer guided maxillary sinus lifting and Group (B) conventional sinus lifting, both groups received allogenic bone blocks for …


Efficacy Of Preemptive Dexamethasone And Diclofenac On Pain Control During Maxillary Alveolar Ridge Horizontal Augmentation Using Cortical Shell Augmentation Technique: A Randomized Clinical Trial, Dina Ayman Fayek D.Ayman, Mohamed Mounir M.Mounir, Lobna Abdrlaziz Aly, Ahmed Abozekry Jun 2023

Efficacy Of Preemptive Dexamethasone And Diclofenac On Pain Control During Maxillary Alveolar Ridge Horizontal Augmentation Using Cortical Shell Augmentation Technique: A Randomized Clinical Trial, Dina Ayman Fayek D.Ayman, Mohamed Mounir M.Mounir, Lobna Abdrlaziz Aly, Ahmed Abozekry

Future Dental Journal

Background: Despite the popularity and success of autogenous cortical shell augmentation, it is a painful procedure, limiting its acceptance by patients specifically if general anesthesia is not a viable option. Aim: This study assessed the analgesic efficacy of co-administration of intramuscular diclofenac sodium and dexamethasone preoperatively. Material and Methods: Patients selected according to the inclusion criteria were randomly divided into 2 equal groups. A similar surgical augmentation technique was performed in both groups using autogenous cortical shell technique. The study group received an intramuscular injection of dexamethasone and diclofenac sodium before surgery, and pain level was measured using VAS (visual …


Therapeutic Effect Of Curcumin, Ginger And Tamarind On Oral And Paraoral Tissues: (Histological Overview), Mona El Deeb, Amany A. Rabea Jun 2023

Therapeutic Effect Of Curcumin, Ginger And Tamarind On Oral And Paraoral Tissues: (Histological Overview), Mona El Deeb, Amany A. Rabea

Future Dental Journal

Background: Biocompatible substances from plant origin have been more in focus in contemporary dentistry. Aim: This review, aimed to highpoint the influence of curcumin, ginger and tamarind on different oral and paraoral tissues from histological point of view. Material and methods: A narrative review was carried out based on publications in PubMed, google and Scopus database. The documents published up to 2021 were included. The research was based on inclusion criteria of 89 studies.Results: Curcumin inhibits alveolar bone resorption, reduces inflammatory cell infiltration, aids in epithelial regeneration and improves salivary glands architecture. Ginger was found to be beneficial in …


Root And Root Canal Morphology Of Premolars In A Sample Of The Lebanese Population: Clinical Considerations, Marie-José Merhej, Roula El Hachem, Hala Sacre, Pascale Salameh, Nabil Ghosn, Alfred Naaman May 2023

Root And Root Canal Morphology Of Premolars In A Sample Of The Lebanese Population: Clinical Considerations, Marie-José Merhej, Roula El Hachem, Hala Sacre, Pascale Salameh, Nabil Ghosn, Alfred Naaman

International Arab Journal of Dentistry

ABSTRACT

Objectives: The aim of this study was to investigate the anatomy of the maxillary and mandibular premolars among a sample of the Lebanese population and to explore their incidence by sex and the symmetry between the left and right sides. Materials and Methods: This retrospective analysis of 250 cone-beam computed tomography (CBCT) scans consisted of 960 maxillary and 972 mandibular premolars. Roots, canals, and morphology types were recorded. Vertucci’s classification was used to categorize the canal morphologies. Fisher’s exact and chi-square tests (P≤.05) were applied.

Results: The majority of maxillary first premolars had two roots (85.3%) with two …


Distal Cantilever Length Comparison In Esthetic Material For Hybrid Implant Prosthesis: An In Vitro Study., Sana Shams Eddin, Elie Jasser, Mohammad Chams Eddin, Carole Abi Ghosn Yared, Joseph Makzoumi, Paul Boulos May 2023

Distal Cantilever Length Comparison In Esthetic Material For Hybrid Implant Prosthesis: An In Vitro Study., Sana Shams Eddin, Elie Jasser, Mohammad Chams Eddin, Carole Abi Ghosn Yared, Joseph Makzoumi, Paul Boulos

International Arab Journal of Dentistry

Objective: the assessment of distal cantilever length in implant supported infrastructure by comparing the load to fracture in two different framework esthetic materials (Zirconia and Polyetheretherketone (PEEK)) with two different cantilevers loading distances (10mm, 15mm). Material and methods: 20 frameworks were fabricated and divided into 4 groups (n=5): according to the material type Peek, zirconia, and according to the cantilever loading distance (10), or (15) mm and a load-to-fracture test was used until complete fracture of specimens occurs. Results: The effect of material type and cantilever loading distance were statistically significant for the mean load-to-fracture values (P< 0.05). The Zirconia group failed at higher fracture loads (817 N) than the Peek one (651 N). Frameworks with 10 mm cantilever loading distance failed at higher fracture loads than specimens with 15 mm. Conclusion: Peek is a suitable material for all-on-four framework reconstruction in specific situations, and there is a higher success rate when the distal cantilever length is kept at minimal value (10mm).