Assessing The Impact Of Increased Air Conditioner Load On Power Quality In Australia, Lianne Mollier, D A. Robinson, Sarath Perera, Victor J. Gosbell, Frank Bucca Dec 2012

Assessing The Impact Of Increased Air Conditioner Load On Power Quality In Australia, Lianne Mollier, D A. Robinson, Sarath Perera, Victor J. Gosbell, Frank Bucca

Dr Duane Robinson

Measurements of performance of existing technology air conditioner systems with regards to their impact on power quality in LV distribution systems are presented. Three types of split-phase air conditioners are studied including direct on line starting, soft starter and inverter fed units. Results of testing and subsequent calculations illustrate that the direct on line and soft starter units do not meet compliance requirements of the relevant standard, and as penetration of air conditioners increases, voltage fluctuations may become a significant problem in some LV distribution systems in Australia.


Issues Affecting Power Engineering Undergraduate Education In Australia, D A. Robinson, Victor J. Gosbell Dec 2012

Issues Affecting Power Engineering Undergraduate Education In Australia, D A. Robinson, Victor J. Gosbell

Dr Duane Robinson

Recent changes to the electric power industry through deregulation and restructuring have had a considerable effect on power engineering education internationally. A number of Australian universities have also noticed a decline in the number of students interested in power engineering subjects, leading to the fewer graduates with power engineering knowledge. With a reduction in graduates and a perception of an aging workforce a shortage of suitably qualified power engineers for industry may be imminent. This paper provides discussion on the current status of university power engineering education within Australia and includes results from a recent Australia-wide survey of the university …


The Application Of Iec 61000-3-6 To Mv Systems In Australia, Victor J. Gosbell, D A. Robinson, Sarath Perera, Alex Baitch Dec 2012

The Application Of Iec 61000-3-6 To Mv Systems In Australia, Victor J. Gosbell, D A. Robinson, Sarath Perera, Alex Baitch

Dr Duane Robinson

IEC 61000-3-6 [1] comprises a number of stages and tests to determine harmonic emission allowances for customers connected to MV or HV networks. Of particular importance is the section concerning loads distributed along a feeder, each having a different fault level. Although a common situation, the treatment given in the IEC standard is poorly described, being largely illustrated by one atypical example. This allows simplifying assumptions to be made which are invalid in practical cases. This paper outlines a more general approach that is relatively easy to apply.


Assessing The Future Of Electrical Power Engineering: A Report On Electrical Power Engineering Manpower Requirements In Australia, Victor Gosbell, D Robinson Dec 2012

Assessing The Future Of Electrical Power Engineering: A Report On Electrical Power Engineering Manpower Requirements In Australia, Victor Gosbell, D Robinson

Dr Duane Robinson

In 2001 the Electric Energy Society of Australia (EESA) developed concerns based on anecdotal evidence that there was a looming shortage of electrical power engineers in Australia. Information from the electrical power industry and academic communities was obtained through two separate survey questionnaires, a discussion workshop, and a number of submissions. This information was collated and compiled into 'Assessing the Future of Electrical Power Engineering: a Report on Electrical Power Engineering Manpower Requirements in Australia'.