Assessing The Impact Of Increased Air Conditioner Load On Power Quality In Australia, Lianne Mollier, D A. Robinson, Sarath Perera, Victor J. Gosbell, Frank Bucca
Assessing The Impact Of Increased Air Conditioner Load On Power Quality In Australia, Lianne Mollier, D A. Robinson, Sarath Perera, Victor J. Gosbell, Frank Bucca
Associate Professor Sarath Perera
Measurements of performance of existing technology air conditioner systems with regards to their impact on power quality in LV distribution systems are presented. Three types of split-phase air conditioners are studied including direct on line starting, soft starter and inverter fed units. Results of testing and subsequent calculations illustrate that the direct on line and soft starter units do not meet compliance requirements of the relevant standard, and as penetration of air conditioners increases, voltage fluctuations may become a significant problem in some LV distribution systems in Australia.
The Application Of Iec 61000-3-6 To Mv Systems In Australia, Victor J. Gosbell, D A. Robinson, Sarath Perera, Alex Baitch
The Application Of Iec 61000-3-6 To Mv Systems In Australia, Victor J. Gosbell, D A. Robinson, Sarath Perera, Alex Baitch
Associate Professor Sarath Perera
IEC 61000-3-6 [1] comprises a number of stages and tests to determine harmonic emission allowances for customers connected to MV or HV networks. Of particular importance is the section concerning loads distributed along a feeder, each having a different fault level. Although a common situation, the treatment given in the IEC standard is poorly described, being largely illustrated by one atypical example. This allows simplifying assumptions to be made which are invalid in practical cases. This paper outlines a more general approach that is relatively easy to apply.