Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences

PDF

Association of Arab Universities

Journal

2024

Prosthodontics

Articles 1 - 3 of 3

Full-Text Articles in Entire DC Network

The Effect Of Preparation Design And Thermal Cycling On The Marginal Accuracy Of Hybrid Ceramic Laminate Veneers, Esraa El Bably, Ossama Saleh Abdelghany, Mostafa Aboushahba, Shereen Ahmed Nossair May 2024

The Effect Of Preparation Design And Thermal Cycling On The Marginal Accuracy Of Hybrid Ceramic Laminate Veneers, Esraa El Bably, Ossama Saleh Abdelghany, Mostafa Aboushahba, Shereen Ahmed Nossair

Future Dental Journal

Aim: This study investigated the effect of preparation design and thermal cycling on the marginal accuracy of hybrid ceramic laminate veneers. Materials and Methods: A total of twenty 3D printed dies of central incisors prepared with 2 preparation designs; butt joint and palatal wrap design were fabricated. Each type of preparation was assigned into 2 subgroups (n=5/each subgroup) according to the type of material used for fabrication of the laminate veneer; hybrid ceramic and lithium disilicate (served as control). Marginal discrepancy was evaluated using a digital microscope before and after thermocycling. Results: Statistically analysis of marginal gaps revealed that before …


Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, Diaa.Zahran@Fue.Edu.Eg, Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, A.Mohamed@Fue.Edu.Eg, Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, Salahhegazy2003@Yahoo.Com, Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, Ahmed.Abdelwahed@Fue.Edu.Eg Jan 2024

Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, Diaa.Zahran@Fue.Edu.Eg, Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, A.Mohamed@Fue.Edu.Eg, Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, Salahhegazy2003@Yahoo.Com, Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, Ahmed.Abdelwahed@Fue.Edu.Eg

Future Dental Journal

Aim this in vitro study was conducted to evaluate the effect of mechanical loading on different implant materials on supporting structures materials and methods: a total of three implant retained overdentures were used in this study, retained by two implants each (Titanium, polyetheretherketon and zirconia) were placed in epoxy resin casts at the canine area using a surgical guide. Soft liner material was used at the distal extension area to mimic the soft tissues. Two linear strain gauges were bonded buccal and lingual to each implant to measure the peri-implant strains during unilateral and bilateral loading. Results: during bilateral loading …


Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, Ahmed.Elghazally@Fue.Edu.Eg, Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, Bassem.Mohsen@Fue.Edu.Eg, Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, Amrelkhadem@Gmail.Com, Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, Hussen.Elsharkawi@Fue.Edu.Eg Jan 2024

Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, Ahmed.Elghazally@Fue.Edu.Eg, Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, Bassem.Mohsen@Fue.Edu.Eg, Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, Amrelkhadem@Gmail.Com, Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, Hussen.Elsharkawi@Fue.Edu.Eg

Future Dental Journal

Background: Several treatment options are planned for completely edentulous patients rehabilitation which were developed to meet patients desires and requirements, starting from conventional complete denture till implant supported fixed full arch cases. Each technique has its own indication and limitations. Passive fit is an important factor for the long-term success of implant- prosthesis, which necessitate accurate transfer of the implant position. Recently, digital impressions have been introduced in dental implant treatment. By the use of scan body and different optical scanning methods, the position of scan bodies can be transferred to a virtual implant position within the dental arch. Material …