Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Entire DC Network

Scan-Rescan And Intra-Observer Variability Of Magnetic Resonance Imaging Of Carotid Atherosclerosis At 1.5 T And 3.0 T, Arvin Vidal, Yves Bureau, Trevor Wade, J David Spence, Brian K Rutt, Aaron Fenster, Grace Parraga Dec 2008

Scan-Rescan And Intra-Observer Variability Of Magnetic Resonance Imaging Of Carotid Atherosclerosis At 1.5 T And 3.0 T, Arvin Vidal, Yves Bureau, Trevor Wade, J David Spence, Brian K Rutt, Aaron Fenster, Grace Parraga

Medical Biophysics Publications

Carotid atherosclerosis measurements for eight subjects at baseline and 14 +/- 2 days later were examined using 1.5 T and 3.0 T magnetic resonance imaging (MRI). A single observer blinded to field strength, subject and timepoint manually segmented carotid artery wall and lumen boundaries in randomized images in five measurement trials. Mean increases in the signal-to-noise ratios (SNR) for T1-weighted images acquired at 3.0 T compared to 1.5 T were 90% (scan) and 80% (rescan). Despite significantly improved SNR and contrast-to-noise ratios (CNR) for images acquired at 3.0 T, vessel wall volume (VWV) intra-observer variability was not significantly different using …


Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk Dec 2008

Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk

Oncology Publications

This study aims to evaluate a new Planned Adaptive software (TomoTherapy Inc., Madison, WI) of the helical tomotherapy system by retrospective verification and adaptive re-planning of radiation treatment. Four patients with different disease sites (brain, nasal cavity, lungs, prostate) were planned in duplicate using the diagnostic planning kVCT data set and MVCT studies of the first treatment fraction with the same optimization parameters for both plan types. The dosimetric characteristics of minimum, maximum, and mean dose to the targets as well as to organs at risk were compared. Both sets of plans were used for calculation of dose distributions in …


Mapping And Quantifying Hyperpolarized 3he Magnetic Resonance Imaging Apparent Diffusion Coefficient Gradients, Andrea Evans, David G Mccormack, Giles Santyr, Grace Parraga Aug 2008

Mapping And Quantifying Hyperpolarized 3he Magnetic Resonance Imaging Apparent Diffusion Coefficient Gradients, Andrea Evans, David G Mccormack, Giles Santyr, Grace Parraga

Medical Biophysics Publications

We measured hyperpolarized 3He magnetic resonance imaging (MRI) apparent diffusion coefficients (ADC) and quantified ADC gradients in each three-by-three voxel region of interest (ROI). Such local ADC gradients can be represented in vector maps showing the magnitude (|G3x3|) and direction of ADC gradients, providing a qualitative visualization tool and quantitative measurement of airway and air space heterogeneity. Twenty-four subjects (15 male, mean age=67+/-7 yr) with global initiative for chronic obstructive lung disease (GOLD) stage II (n=9, mean age 68+/-6 yr), GOLD stage III chronic obstructive pulmonary disease (COPD; n=7, mean age 67+/-8 yr), and age-matched healthy volunteers (n=8, mean age …


Quantification Of Carotid Vessel Wall And Plaque Thickness Change Using 3d Ultrasound Images, Bernard Chiu, Micaela Egger, J David Spence, Grace Parraga, Aaron Fenster Aug 2008

Quantification Of Carotid Vessel Wall And Plaque Thickness Change Using 3d Ultrasound Images, Bernard Chiu, Micaela Egger, J David Spence, Grace Parraga, Aaron Fenster

Medical Biophysics Publications

Quantitative measurements of carotid plaque burden progression or regression are important in monitoring patients and in evaluation of new treatment options. 3D ultrasound (US) has been used to monitor the progression or regression of carotid artery plaques. This paper reports on the development and application of a method used to analyze changes in carotid plaque morphology from 3D US. The technique used is evaluated using manual segmentations of the arterial wall and lumen from 3D US images acquired in two imaging sessions. To reduce the effect of segmentation variability, segmentation was performed five times each for the wall and lumen. …


Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk May 2008

Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk

Oncology Publications

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both "type" tests to be performed in the factory and "site" tests to …