Simulation Model Of A Grid-Connected Single-Phase Photovoltaic System In Pscad/Emtdc, Brian K. Perera, Sridhar R. Pulikanti, Philip Ciufo, Sarath Perera Feb 2013

Simulation Model Of A Grid-Connected Single-Phase Photovoltaic System In Pscad/Emtdc, Brian K. Perera, Sridhar R. Pulikanti, Philip Ciufo, Sarath Perera

Dr Philip Ciufo

In this paper, a complete simulation model of a grid-connected single-phase two-stage photovoltaic (PV) system with associated controllers is presented. The simulation model is developed in PSCAD/EMTDC simulation program. The component models of the grid-connected PV system include a PV array, a dc-dc boost converter, a voltage source converter (VSC) and an LCL filter. Components of the LCL filter, the dc-link capacitor of the VSC and the inductor of the dc-dc boost converter are established theoretically and that are used in modelling the grid-connected PV system. The control architecture of the presented system incorporates a synchronous reference frame phase-locked-loop (s-PLL), …


Comparison Of Methodologies For Assessment Of Harmonic Current Emission Limits For Large Installations Connected To Lv Networks, Biyanvilage Perera, Sarath Perera, Philip Ciufo, Victor J. Gosbell Feb 2013

Comparison Of Methodologies For Assessment Of Harmonic Current Emission Limits For Large Installations Connected To Lv Networks, Biyanvilage Perera, Sarath Perera, Philip Ciufo, Victor J. Gosbell

Dr Philip Ciufo

With the proliferation of large, disturbing installations (loads and distribution generators) connected to public low voltage networks, managing the harmonic voltage levels in the network has become a key concern to distribution network service providers (DNSPs). Therefore, it is important that DNSPs limit the harmonic current emission by individual installations. This paper reviews a number of methodologies that exist in the current technical literature in relation to the assessment of harmonic current emission limits for disturbing installations connected to the public LV network. Application of these methodologies is demonstrated through a case study on a test network. The study shows …


Impact Of Mains Connected Three-Phase Induction Motor Loading Levels On Network Voltage Unbalance Attenuation, Upuli Jayatunga, Sarath Perera, Philip Ciufo Feb 2013

Impact Of Mains Connected Three-Phase Induction Motor Loading Levels On Network Voltage Unbalance Attenuation, Upuli Jayatunga, Sarath Perera, Philip Ciufo

Dr Philip Ciufo

Voltage unbalance (VU) in power systems should be managed in a systematic manner in order to minimise its adverse effects on both customer equipment and supply utilities. It is a well known fact that three-phase induction motor performance can be significantly affected in the presence of supply voltage unbalance. It is also known that three-phase induction motors can help to reduce pre-existing network voltage unbalance levels. Recently undertaken research aligned with IEC/TR 61000-3-13:2008 Technical Report on voltage unbalance management (emission allocation and emission assessment) have quantified the contribution made by induction motors to the net voltage unbalance at a point …


Flicker Propagation Analysis In Distribution Networks With Embedded Generation, D Perera, L Meegahapola, S Perera, P Ciufo Feb 2013

Flicker Propagation Analysis In Distribution Networks With Embedded Generation, D Perera, L Meegahapola, S Perera, P Ciufo

Dr Philip Ciufo

Embedded generators such as wind generators can produce observable voltage fluctuations during variable wind conditions hence flicker. The flicker produced by such intermittent and fluctuating generating sources can propagate to other parts of the distribution network while creating power quality issues in distribution feeders. This study presents a flicker emission analysis for a doubly-fed induction generator (DFIG) based wind farm and investigate the pertinent factors which influence flicker propagation and attenuation in distribution feeders. Study has shown that voltage fluctuations are significantly influenced by the attenuation characteristics of various load types (i.e. constant power, impedance and current loads) connected to …


A Study On The Suitability Of Cable Models To Simulate Switching Transients In A 132 Kv Underground Cable, Muhamad Zalani Daud, P Ciufo, S Perera Dec 2012

A Study On The Suitability Of Cable Models To Simulate Switching Transients In A 132 Kv Underground Cable, Muhamad Zalani Daud, P Ciufo, S Perera

Dr Philip Ciufo

Switching transients resulting from the energisation of high voltage cable systems may have a significant effect on both the cables being switched as well as the power system components in the vicinity. The impacts of these transients on such cables are measured based on the stress arising as a result of the voltage and current peaks and the frequency of oscillatory transients. These quantities are typically obtained from a simulation by using a suitable cable model, normally with the capability to predict the transient behaviour in the range up to several 10 kHz. To obtain a cable model that enables …