Open Access. Powered by Scholars. Published by Universities.®
Social and Behavioral Sciences Commons™
Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 6 of 6
Full-Text Articles in Social and Behavioral Sciences
2d Versus 3d Collaborative Online Spaces For Student Team Meetings: Comparing A Web Conferencing Environment And A Video-Augmented Virtual World, Sasha Nikolic, Mark Jw Lee, Peter J. Vial
2d Versus 3d Collaborative Online Spaces For Student Team Meetings: Comparing A Web Conferencing Environment And A Video-Augmented Virtual World, Sasha Nikolic, Mark Jw Lee, Peter J. Vial
Faculty of Engineering and Information Sciences - Papers: Part A
BACKGROUND OR CONTEXT Teamwork is an integral component of any engineering degree, but students often have difficulty organising team meetings outside of class times due to discrepancies in their individual study timetables as well as their family and work commitments. Rich-media synchronous online technologies such as video/web conferencing and virtual worlds can be used to help address this problem by enabling anyplace, anytime interaction, while at the same time mirroring the communication modes students will encounter in their future workplaces. However, not much is known about how these technologies compare with one another for facilitating different types of collaborative learning …
A New Approach For Classification And Characterization Of Voltage Dips And Swells Using 3d Polarization Ellipse Parameters, Mollah R. Alam, Kashem M. Muttaqi, Abdesselam Bouzerdoum
A New Approach For Classification And Characterization Of Voltage Dips And Swells Using 3d Polarization Ellipse Parameters, Mollah R. Alam, Kashem M. Muttaqi, Abdesselam Bouzerdoum
Faculty of Engineering and Information Sciences - Papers: Part A
This paper presents a new method for classification and characterization of voltage dips and swells in electricity networks. The proposed method exploits unique signatures and parameters of three phase voltage signals extracted from the polarization ellipse in three-dimensional (3D) co-ordinates. Five ellipse parameters, which include azimuthal angle, elevation, tilt, semi-minor axis and semi-major axis, are used to classify and characterize voltage dips and swells. Seven types of voltage dips, which include a total of 19 groups of dips incorporating different kinds of balanced (three-phase dips) and unbalanced (single-phase or double-phase) dips, are identified and successfully classified using the 3D polarization …
3d Bridge Microdosimeter: Charge Collection Study And Application To Rbe Studies In 12C Radiation Therapy, Linh T. Tran, Dale A. Prokopovich, Susanna Guatelli, Marco Petasecca, Michael L. F Lerch, Mark I. Reinhard, Anatoly B. Rosenfeld
3d Bridge Microdosimeter: Charge Collection Study And Application To Rbe Studies In 12C Radiation Therapy, Linh T. Tran, Dale A. Prokopovich, Susanna Guatelli, Marco Petasecca, Michael L. F Lerch, Mark I. Reinhard, Anatoly B. Rosenfeld
Faculty of Engineering and Information Sciences - Papers: Part A
Radiotherapy using heavy ion beam such as Carbon-ion has the advantage for the treatment of deep-seated tumour over conventional radiotherapy with X-rays due to an enhanced dose deposition in the Bragg peak (BP) at the end of the ion range. The highest dose can be deposited in the tumour with much lower doses to the surrounding healthy tissue. The Relative Biological Effectiveness (RBE) of a carbon-ion radiotherapy beam greatly depends on a depth of the target volume in the body and the nuclear fragmentation process that increases close to the BP or spread out BP (SOBP) as well as neutrons. …
Effect Of Mesh On Springback In 3d Finite Element Analysis Of Flexible Microrolling, Feijun Qu, Zhengyi Jiang, Haina Lu
Effect Of Mesh On Springback In 3d Finite Element Analysis Of Flexible Microrolling, Feijun Qu, Zhengyi Jiang, Haina Lu
Faculty of Engineering and Information Sciences - Papers: Part A
In flexible microrolling, springback in thickness direction is a critical indicator to determine the forming quality. Accurate prediction of springback is one of the significant aspects in the finite element analysis of flexible microrolling. Meshing is a step of great importance in finite element analysis of manufacturing process as it directly determines the accuracy of the FEA results as well as the requested computational time. This paper presents a numerical study on revealing the mesh effects on the accuracy of springback estimation utilising ABAQUS/Standard for modelling and analyses. Two types of meshes with six mesh sizes for each mesh type …
Evaluation Of 3d Gamma Index Calculation Implemented In Two Commercial Dosimetry Systems, Aitang Xing, Sankar Arumugam, Shrikant Deshpande, Armia George, Philip J. Vial, Lois C. Holloway, Gary Goozee
Evaluation Of 3d Gamma Index Calculation Implemented In Two Commercial Dosimetry Systems, Aitang Xing, Sankar Arumugam, Shrikant Deshpande, Armia George, Philip J. Vial, Lois C. Holloway, Gary Goozee
Faculty of Engineering and Information Sciences - Papers: Part A
3D Gamma index is one of the metrics which have been widely used for clinical routine patient specific quality assurance for IMRT, Tomotherapy and VMAT. The algorithms for calculating the 3D Gamma index using global and local methods implemented in two software tools: PTW-VeriSoft (R) r as a part of OCTIVIUS 4D dosimeter systems and 3DVH (TM) from Sun Nuclear were assessed. The Gamma index calculated by the two systems was compared with manual calculated for one data set. The Gamma pass rate calculated by the two systems was compared using 3%/3mm, 2%/2mm, 3%/2mm and 2%/3mm for two additional data …
Is A Quasi-3d Dosimeter Better Than A 2d Dosimeter For Tomotherapy Delivery Quality Assurance?, Aitang Xing, Shrikant Deshpande, Sankar Arumugam, Armia George, Lois C. Holloway, Philip J. Vial, Gary Goozee
Is A Quasi-3d Dosimeter Better Than A 2d Dosimeter For Tomotherapy Delivery Quality Assurance?, Aitang Xing, Shrikant Deshpande, Sankar Arumugam, Armia George, Lois C. Holloway, Philip J. Vial, Gary Goozee
Faculty of Engineering and Information Sciences - Papers: Part A
Delivery quality assurance (DQA) has been performed for each Tomotherapy patient either using ArcCHECK or MatriXX Evolution in our clinic since 2012. ArcCHECK is a quasi-3D dosimeter whereas MatriXX is a 2D detector. A review of DQA results was performed for all patients in the last three years, a total of 221 DQA plans. These DQA plans came from 215 patients with a variety of treatment sites including head-neck, pelvis, and chest wall. The acceptable Gamma pass rate in our clinic is over 95% using 3mm and 3% of maximum planned dose with 10% dose threshold. The mean value and …