Open Access. Powered by Scholars. Published by Universities.®

Social and Behavioral Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Sports Studies

The University of San Francisco

Exercise

Publication Year

Articles 1 - 3 of 3

Full-Text Articles in Social and Behavioral Sciences

Bioharness Multivariable Monitoring Device. Part I: Validity, James A. Johnstone, Paul A. Ford, Gerwyn Hughes, Tim Watson, Andrew T. Garrett Jan 2012

Bioharness Multivariable Monitoring Device. Part I: Validity, James A. Johnstone, Paul A. Ford, Gerwyn Hughes, Tim Watson, Andrew T. Garrett

Kinesiology (Formerly Exercise and Sport Science)

The BioharnessTM monitoring system may provide physiological information on human performance but there is limited information on its validity. The objective of this study was to assess the validity of all 5 BioharnessTM variables using a laboratory based treadmill protocol. 22 healthy males participated. Heart rate (HR), Breathing Frequency (BF) and Accelerometry (ACC) precision were assessed during a discontinuous incremental (0- 12 km·h-1) treadmill protocol. Infra-red skin temperature (ST) was assessed during a 45 min-1 sub-maximal cycle ergometer test, completed twice, with environmental temperature controlled at 20 ±0.1 °C and 30 ± 0.1 °C. Posture (P) was assessed using a …


Bioharness Multivariable Monitoring Device. Part Ii: Reliability, James A. Johnstone, Paul A. Ford, Gerwyn Hughes, Tim Watson, Andrew T. Garrett Jan 2012

Bioharness Multivariable Monitoring Device. Part Ii: Reliability, James A. Johnstone, Paul A. Ford, Gerwyn Hughes, Tim Watson, Andrew T. Garrett

Kinesiology (Formerly Exercise and Sport Science)

The BioharnessTM monitoring system may provide physiological information on human performance but the reliability of this data is fundamental for confidence in the equipment being used. The objective of this study was to assess the reliability of each of the 5 BioharnessTM variables using a treadmill based protocol. 10 healthy males participated. A between and within subject design to assess the reliability of Heart rate (HR), Breathing Frequency (BF), Accelerometry (ACC) and Infra-red skin temperature (ST) was completed via a repeated, discontinuous, incremental treadmill protocol. Posture (P) was assessed by a tilt table, moved through 160o. Between subject data reported …


Intra-Arterial Blood Pressure Characteristics During Submaximal Cycling And Recovery, Julia Orri, S E. Griffin, Robert A. Robergs, David S. James, D R. Wagner, R Quintana Jan 2004

Intra-Arterial Blood Pressure Characteristics During Submaximal Cycling And Recovery, Julia Orri, S E. Griffin, Robert A. Robergs, David S. James, D R. Wagner, R Quintana

Kinesiology (Formerly Exercise and Sport Science)

The purpose of this study was to measure intra-arterial (IA) blood pressure from rest to steady-state submaximal exercise and immediately post-exercise. Beat-to-beat blood pressure was compared to breath-by-breath VO2 during steady-state and maximal exercise. Fourteen normotensive subjects volunteered. Systolic (SBP), diastolic (DBP) and mean (mBP) blood pressure was measured from rest to steady state during cycling at 45, 60, and 75% maximal power output (POmax). BP was assessed during recovery from VO2peak through 2 min of cycling at 50 W. During the rest to exercise transition, mBP decreased from 103.41 ± 9.4 to 90.1 ± 8.9 mmHg after 11.6 ± …