Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences

2019

Institution
Keyword
Publication
Publication Type

Articles 1 - 30 of 36

Full-Text Articles in Physics

Characterization And Longitudinal Assessment Of Daily Quality Assurance For An Mr-Guided Radiotherapy (Mrgrt) Linac, Kathryn Mittauer Nov 2019

Characterization And Longitudinal Assessment Of Daily Quality Assurance For An Mr-Guided Radiotherapy (Mrgrt) Linac, Kathryn Mittauer

All Publications

No abstract provided.


Average Speech Directivity, Samuel D. Bellows, Claire M. Pincock, Jennifer K. Whiting, Timothy W. Leishman Nov 2019

Average Speech Directivity, Samuel D. Bellows, Claire M. Pincock, Jennifer K. Whiting, Timothy W. Leishman

Directivity

Speech directivity describes the angular dependence of acoustic radiation from a talker’s mouth and nostrils and diffraction about his or her body and chair (if seated). It is an essential physical aspect of communication affecting sounds and signals in acoustical environments, audio, and telecommunication systems. Because high-resolution, spherically comprehensive measurements of live, phonetically balanced speech have been unavailable in the past, the authors have undertaken research to produce and share such data for simulations of acoustical environments, optimizations of microphone placements, speech studies, and other applications. The measurements included three male and three female talkers who repeated phonetically balanced passages …


9th Annual Postdoctoral Science Symposium, University Of Texas Md Anderson Cancer Center Postdoctoral Association Sep 2019

9th Annual Postdoctoral Science Symposium, University Of Texas Md Anderson Cancer Center Postdoctoral Association

Annual Postdoctoral Science Symposium Abstracts

The mission of the Annual Postdoctoral Science Symposium (APSS) is to provide a platform for talented postdoctoral fellows throughout the Texas Medical Center to present their work to a wider audience. The MD Anderson Postdoctoral Association convened its inaugural Annual Postdoctoral Science Symposium (APSS) on August 4, 2011.

The APSS provides a professional venue for postdoctoral scientists to develop, clarify, and refine their research as a result of formal reviews and critiques of faculty and other postdoctoral scientists. Additionally, attendees discuss current research on a broad range of subjects while promoting academic interactions and enrichment and developing new collaborations.


Inference Of Language Functional Network In Healthy, Cancerous And Bilingual Brains By Fmri And Network Modeling, Qiongge Li Sep 2019

Inference Of Language Functional Network In Healthy, Cancerous And Bilingual Brains By Fmri And Network Modeling, Qiongge Li

Dissertations, Theses, and Capstone Projects

We study the underlying mechanism by which language processing occurs in the human brain using inference methods on functional magnetic resonance imaging data. The data analyzed stems from several cohorts of subjects; a monolingual group, a bilingual group, a healthy control group and one diseased case. We applied a complex statistical inference pipeline to determine the network structure of brain components involved with language. This healthy network reveals a fully connected triangular relationship between the pre-Supplementary Motor Area (pre-SMA), the Broca's Area (BA), and the ventral Pre-Motor Area (PreMA) in the left hemisphere. This "triangle'' shows consistently in all the …


Table Of Contents Aug 2019

Table Of Contents

Journal of the South Carolina Academy of Science

No abstract provided.


Effective Statistical Energy Function Based Protein Un/Structure Prediction, Avdesh Mishra Aug 2019

Effective Statistical Energy Function Based Protein Un/Structure Prediction, Avdesh Mishra

University of New Orleans Theses and Dissertations

Proteins are an important component of living organisms, composed of one or more polypeptide chains, each containing hundreds or even thousands of amino acids of 20 standard types. The structure of a protein from the sequence determines crucial functions of proteins such as initiating metabolic reactions, DNA replication, cell signaling, and transporting molecules. In the past, proteins were considered to always have a well-defined stable shape (structured proteins), however, it has recently been shown that there exist intrinsically disordered proteins (IDPs), which lack a fixed or ordered 3D structure, have dynamic characteristics and therefore, exist in multiple states. Based on …


Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations Of Microdosimetry, Mark A. Newpower Aug 2019

Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations Of Microdosimetry, Mark A. Newpower

Dissertations & Theses (Open Access)

Proton therapy is a radiotherapy modality that can offer a better physical dose distribution when compared to photon radiotherapy by taking advantage of the Bragg peak, a narrow region of rapid energy loss. Proton therapy is also known to offer an enhanced relative biological effectiveness (RBE) compared to photons. In the current clinical standard, RBE is fixed at 1.1 at all points along the proton beam, meaning protons are assumed to require 10% less dose than photons to achieve target coverage and organ at risk (OAR) sparing. However, there is mounting clinical evidence, and a significant number of in vitro …


Quantifying Uncertainty In A Measurement-Based Assessment Of Relative Biological Effectiveness In Carbon Ion Radiotherapy, Shannon Hartzell Aug 2019

Quantifying Uncertainty In A Measurement-Based Assessment Of Relative Biological Effectiveness In Carbon Ion Radiotherapy, Shannon Hartzell

Dissertations & Theses (Open Access)

One of the largest inconsistencies in dose delivered during carbon ion therapy is due to uncertainties in relative biological effectiveness (RBE), a value that is calculated via one of several clinically implemented algorithms. This study investigates the uncertainty in measured microdosimetric parameters for RBE calculation by the Microdosimetric Kinetic Model (MKM), Repair Misrepair Fixation model (RMF), and Local Effect Model I (LEM) using a Tissue Equivalent Proportional Counter (TEPC).

Microdosimetric spectra, kinetic energy spectra, and dose fragment contributions were calculated using Monte Carlo (GEANT IV) for monoenergetic and SOBP carbon beams of clinical energy. From microdosimetric spectra, lineal energy values …


Commissioning Of Micro-Cube Thermoluminescent Dosimeters For Small Field Dosimetry Quality Assurance In Radiotherapy, Brandon Luckett Aug 2019

Commissioning Of Micro-Cube Thermoluminescent Dosimeters For Small Field Dosimetry Quality Assurance In Radiotherapy, Brandon Luckett

Dissertations & Theses (Open Access)

Small field dosimetry presents complications and uncertainties that could be circumvented by using detectors which are smaller than the radiation field. This study evaluates the reproducibility and accuracy of TLD micro-cubes for use in stereotactic radiosurgery (SRS) remote auditing quality assurance (QA) for treatment centers participating in clinical trials. This study tested the hypothesis that TLD micro-cubes could be commissioned to evaluate small field dosimetry, and provide reproducibility within 3%, as well as assure agreement between measured dose and calculated doses to within 5%.

The aims of this thesis were to characterize and commission TLD micro-cubes as well as to …


Improving 3d Printed Prosthetics With Sensors And Motors, Rachel Zarin Jul 2019

Improving 3d Printed Prosthetics With Sensors And Motors, Rachel Zarin

Honors Projects

A 3D printed hand and arm prosthetic was created from the idea of adding bionic elements while keeping the cost low. It was designed based on existing models, desired functions, and materials available. A tilt sensor keeps the hand level, two motors move the wrist in two different directions, a limit switch signals the fingers to open and close, and another motor helps open and close the fingers. All sensors and motors were built on a circuit board, programmed using an Arduino, and powered by a battery. Other supporting materials include metal brackets, screws, guitar strings, elastic bands, small clamps, …


Development And Long-Term Stability Of A Comprehensive Daily Qa Program For A Modern Pencil Beam Scanning (Pbs) Proton Therapy Delivery System, Suresh Rana, Jaafar Bennouna, Alonso Gutierrez Jun 2019

Development And Long-Term Stability Of A Comprehensive Daily Qa Program For A Modern Pencil Beam Scanning (Pbs) Proton Therapy Delivery System, Suresh Rana, Jaafar Bennouna, Alonso Gutierrez

Alonso Gutierrez

No abstract provided.


Development And Long-Term Stability Of A Comprehensive Daily Qa Program For A Modern Pencil Beam Scanning (Pbs) Proton Therapy Delivery System, Suresh Rana, Jaafar Bennouna, Alonso Gutierrez Jun 2019

Development And Long-Term Stability Of A Comprehensive Daily Qa Program For A Modern Pencil Beam Scanning (Pbs) Proton Therapy Delivery System, Suresh Rana, Jaafar Bennouna, Alonso Gutierrez

Jaafar Bennouna

No abstract provided.


Development And Long-Term Stability Of A Comprehensive Daily Qa Program For A Modern Pencil Beam Scanning (Pbs) Proton Therapy Delivery System, Suresh Rana, Jaafar Bennouna, Alonso Gutierrez Jun 2019

Development And Long-Term Stability Of A Comprehensive Daily Qa Program For A Modern Pencil Beam Scanning (Pbs) Proton Therapy Delivery System, Suresh Rana, Jaafar Bennouna, Alonso Gutierrez

Suresh Rana

No abstract provided.


Stray Radiation Dose From X-Ray And Proton Beam Radiation Therapies, Christopher William Schneider Jun 2019

Stray Radiation Dose From X-Ray And Proton Beam Radiation Therapies, Christopher William Schneider

LSU Doctoral Dissertations

The growing population of cancer survivors at risk of radiation induced side-effects is a public health concern. These side-effects include serious conditions such as second cancers, the majority of which occur outside of the primary treatment volume. Radiotherapy treatment planning systems systematically underestimate the dose to tissues out-of-field. Attempts to predict and reduce the risks of radiogenic side effects require accurate and personalized knowledge of the out-of-field radiation dose to patients. The long-term goal of this research is to provide clinical and research tools necessary to reduce the risk of radiotherapy side effects and improve the health outcomes of radiotherapy …


Determination Of Scatter Fractions, Albedos, And Tenth Value Layers For Shielding Of Synchrotron Beamline Hutches, Bethany Lynn Broekhoven May 2019

Determination Of Scatter Fractions, Albedos, And Tenth Value Layers For Shielding Of Synchrotron Beamline Hutches, Bethany Lynn Broekhoven

LSU Master's Theses

Synchrotron facilities require substantial amounts of shielding to protect facility staff and researchers. To meet mandatory exposure limits, the traditional combination of time, distance, and shielding of the radiation source are utilized. Because of continuous 24-7 operation of most synchrotrons, time is the least useful tool. The experimental stations for synchrotron x-ray beamlines, called hutches, enforce a minimum distance from the source, but shielding provided by hutch walls is still the principal tool for a synchrotron facility. Currently there is no single resource for synchrotron beamline hutch shielding design in the literature; most hutch shielding is designed through either over-simplified …


Framework For Algorithmically Optimizing Longitudinal Health Outcomes: Examples In Cancer Radiotherapy And Occupational Radiation Protection, Lydia Joyce Wilson May 2019

Framework For Algorithmically Optimizing Longitudinal Health Outcomes: Examples In Cancer Radiotherapy And Occupational Radiation Protection, Lydia Joyce Wilson

LSU Doctoral Dissertations

Background: Advancements in the treatment of non-infectious disease have enabled survival rates to steadily increase in recent decades (e.g., diabetes, heart disease, and cancer). Epidemiological studies have revealed that the treatments for these diseases can have life-threatening and/or life–altering effects. Thus, realizing the full beneficial potential of advanced treatments necessitates new tools to algorithmically consider all major components of the health outcome, including benefit and detriment. The goal of this dissertation was to develop a framework for improving projected health outcomes following planned radiation exposures in consideration of all beneficial and detrimental, early and late, and fatal and non-fatal …


Feedforward And Feedback Signals In The Olfactory System, Srimoy Chakraborty May 2019

Feedforward And Feedback Signals In The Olfactory System, Srimoy Chakraborty

Graduate Theses and Dissertations

The conglomeration of myriad activities in neural systems often results in prominent oscillations. The primary goal of the research presented in this thesis was to study effects of sensory stimulus on the olfactory system of rats, focusing on the olfactory bulb (OB) and the anterior piriform cortex (aPC). Extracellular electrophysiological measurements revealed distinct frequency bands of oscillations in OB and aPC. However, how these oscillatory fluctuations help the animal to process sensory input is not clearly understood. Here we show high frequency oscillations in olfactory bulb carry feedforward signals to anterior piriform cortex whereas feedback from the aPC is predominantly …


Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre May 2019

Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre

Honors Scholar Theses

Abnormal ocular motility is a common manifestation of many underlying pathologies particularly those that are neurological. Dynamics of saccades, when the eye rapidly changes its point of fixation, have been characterized for many neurological disorders including concussions, traumatic brain injuries (TBI), and Parkinson’s disease. However, widespread saccade analysis for diagnostic and research purposes requires the recognition of certain eye movement parameters. Key information such as velocity and duration must be determined from data based on a wide set of patients’ characteristics that may range in eye shapes and iris, hair and skin pigmentation [36]. Previous work on saccade analysis has …


Acr Accreditation For Utah Valley Hospital’S Radiation Oncology Center, Remy Manigold May 2019

Acr Accreditation For Utah Valley Hospital’S Radiation Oncology Center, Remy Manigold

UNLV Theses, Dissertations, Professional Papers, and Capstones

Becoming an accredited clinic through the American College of Radiology (ACR) and their Radiation Oncology Practice Accreditation (ROPA) program will provide third-party evaluation of patient care to ensure the best treatment possible for patients.

Talk of getting ACR accreditation has occurred in the past for Utah Valley Hospital/American Fork Hospital, but at the time it was seen as something that did not provide sufficient value vs. the cost. The recent One Intermountain restructuring is intended to unify all of the Intermountain Healthcare radiation oncology centers in Utah so the Radiation Oncology Director has set the goal that all Intermountain radiation …


Evaluation Of Ventilation Assistance For Improving Respiratory Reproducibility In Radiation Therapy, Cameron J. Sprowls Apr 2019

Evaluation Of Ventilation Assistance For Improving Respiratory Reproducibility In Radiation Therapy, Cameron J. Sprowls

LSU Master's Theses

Background: Respiratory motion affects all tumor sites in the thorax and abdomen. Variations of the respiratory pattern cause variations of the tumor motion which can result in differences between the planned and delivered dose distributions. Previous breathing guidance techniques have been investigated to improve respiratory reproducibility; however, ventilation assistance has not been investigated. We evaluated using bi-level positive airway pressure (BIPAP) ventilation assistance for improving respiratory reproducibility in patients with tumor sites impacted by respiratory motion.

Methods: Written informed consent was obtained for 10 patients currently undergoing radiation therapy treatment. Patients participated in sessions over their course of treatment, which …


Quantification Of Contrast-Enhanced Ultrasound, Joseph Pathoulas Apr 2019

Quantification Of Contrast-Enhanced Ultrasound, Joseph Pathoulas

All College Thesis Program, 2016-2019

The aim of this experiment was to investigate the effect of manipulating ultrasound scanner settings on time-intensity curve parameters in a tube perfusion phantom system using contrast-enhanced ultrasound imaging. Imaging was performed using a Philips LOGIQ E9 ultrasound scanner equipped with a C1-6VN transducer and utilized two different microbubble contrast agents: Definity and Lumason. The ultrasound scanner settings manipulated included: gain, dynamic range, and frequency. Additionally, relative microbubble concentration, microbubble type, and perfusion flow rate were manipulated. Four time-intensity curve parameters (time to peak, area under curve, gradient, peak intensity) were measured from linearized pixel data. Time to peak was …


Development And Long-Term Stability Of A Comprehensive Daily Qa Program For A Modern Pencil Beam Scanning (Pbs) Proton Therapy Delivery System, Suresh Rana, Jaafar Bennouna, Alonso Gutierrez Apr 2019

Development And Long-Term Stability Of A Comprehensive Daily Qa Program For A Modern Pencil Beam Scanning (Pbs) Proton Therapy Delivery System, Suresh Rana, Jaafar Bennouna, Alonso Gutierrez

All Publications

No abstract provided.


An Investigation Of The Detection Capability Of Pulsed Wave Duplex Doppler Of Low Grade Stenosis Using Ultrasound Contrast Agent Microbubbles – An In-Vitro Study, Jacinta Browne, Deirdre King, Andrew Fagan, Deepa Chari, Carmel Moran Apr 2019

An Investigation Of The Detection Capability Of Pulsed Wave Duplex Doppler Of Low Grade Stenosis Using Ultrasound Contrast Agent Microbubbles – An In-Vitro Study, Jacinta Browne, Deirdre King, Andrew Fagan, Deepa Chari, Carmel Moran

Articles

Objective: The objective of the study was to investigate whether clinically used ultrasonic contrast agents improved the accuracy of spectral Doppler ultrasound in the detection of low grade (< 50%) renal artery stenosis. Low grade stenoses in the renal artery are notoriously difficult to reliably detect using Doppler ultrasound due to difficulties such as overlying fat and bowel gas.

Methods: A range of anatomically-realistic renal artery phantoms with varying low degrees of stenosis (0, 30 and 50%) were constructed and peak velocity data was measured from within the pre-stenotic and mid-stenotic regions in each phantom, for both unenhanced and contrast-enhanced spectral Doppler data acquisitions. The effect of a 20mm overlying fat layer on the ultrasound beam distortion and phase aberration, and hence on the measured peak velocity data, was also …


Table Of Contents Mar 2019

Table Of Contents

Journal of the South Carolina Academy of Science

No abstract provided.


Use Of Novel Anthropomorphic Breast Ultrasound Phantoms For Radiology Resident Education, Jacinta Browne, Chris Gu, Robert Fazzio, Andrew Fagan, Donald Tradup, Nicholas Hangiandreou Feb 2019

Use Of Novel Anthropomorphic Breast Ultrasound Phantoms For Radiology Resident Education, Jacinta Browne, Chris Gu, Robert Fazzio, Andrew Fagan, Donald Tradup, Nicholas Hangiandreou

Articles

Purpose: This study evaluated the training and assessment role of anthropomorphic breast ultrasound phantoms which simulated both the morphological and sonographic characteristics of breast tissue, including lesions, in a group of radiology residents at a large academic medical center. Methods: This was a prospective study involving 9 residents across all years (2nd–4th year) of a radiology residency program. Baseline assessments of all residents ability to detect and characterize lesions in P-I were carried out, followed by a two-hour teaching session on the same phantom. All residents underwent a post-training, final assessment on P-II to evaluate changes in …


Dynamic Light Scattering Optical Coherence Tomography To Probe Motion Of Subcellular Scatterers., Nico J J Arezza, Marjan Razani, Michael C Kolios Feb 2019

Dynamic Light Scattering Optical Coherence Tomography To Probe Motion Of Subcellular Scatterers., Nico J J Arezza, Marjan Razani, Michael C Kolios

Medical Biophysics Publications

Optical coherence tomography (OCT) is used to provide anatomical information of biological systems but can also provide functional information by characterizing the motion of intracellular structures. Dynamic light scattering OCT was performed on intact, control MCF-7 breast cancer cells and cells either treated with paclitaxel to induce apoptosis or deprived of nutrients to induce oncosis. Autocorrelations (ACs) of the temporal fluctuations of OCT intensity signals demonstrate a significant decrease in decorrelation time after 24 h in both the paclitaxel-treated and nutrient-deprived cell groups but no significant differences between the two groups. The acquired ACs were then used as input for …


Comforting With Mathematics: A Case Study, Michael J. Goldstein Jan 2019

Comforting With Mathematics: A Case Study, Michael J. Goldstein

Journal of Humanistic Mathematics

Death by suicide often leaves behind grieving family members with unanswered questions. Of these concerns, fear that their loved one suffered or felt regret is common. When the method of suicide was jumping from height, that answer can easily be determined using basic kinematics. Despite the perception that mathematics is a cold, calculating field, it can provide a clear, definitive answer and comfort those left behind.


High Frequency Percussive Ventilation For Tumor Motion Immobilization, Ina Marina Sala Jan 2019

High Frequency Percussive Ventilation For Tumor Motion Immobilization, Ina Marina Sala

Wayne State University Dissertations

This work investigates the use of High Frequency Percussive Ventilation as a technique for respiratory motion mitigation in radiotherapy. This technique was extensively investigated in several prospective and retrospective studies.

In an initial prospective study, we evaluated the feasibility of HFPV and chest-wall motion reduction, by recruiting 15 healthy volunteers to undergo HFPV with three commercially available interfaces. For direct tumor motion immobilization, a second prospective study was performed in which with ten lung cancer patients underwent HFPV while imaged with high frame rate fluoroscopy. Diaphragm motion and image artifacts were quantified in a prospective study of a healthy volunteer …


Utilizing Log Files For Treatment Planning And Delivery Qa In Radiotherapy, Carl W. Stanhope Jan 2019

Utilizing Log Files For Treatment Planning And Delivery Qa In Radiotherapy, Carl W. Stanhope

Wayne State University Theses

Purpose: Monte Carlo-based log file quality assurance (LF-MC QA) is investigated as an alternative method to phantom-based patient-specific quality assurance in radiotherapy (e.g. ArcCHECK QA (AC QA)).

Methods: First, the shortcomings of AC QA were investigated. The sensitivity dependence of ArcCHECK diodes on dose rate (in-field) and energy (primarily out-of-field) was quantified. LF-MC QA was then analyzed on the phantom geometry. Planned (‘Plan’) and LF-reconstructed CS and MC doses were compared with each other and AC measurement via statistical (mean ± StdDev(σ)) and gamma analyses to isolate dosimetric uncertainties and quantify the relative accuracies of AC QA and LF-MC QA. …


Using Fundamental Properties Of Light To Investigate Photonic Effects In Condensed Matter And Biological Tissues, Laura A. Sordillo Jan 2019

Using Fundamental Properties Of Light To Investigate Photonic Effects In Condensed Matter And Biological Tissues, Laura A. Sordillo

Dissertations and Theses

Light possesses characteristics such as polarization, wavelength and coherence. The interaction of light and matter, whether in a semiconductor or in a biological sample, can reveal important information about the internal properties of a system. My thesis focuses on two areas: photocarriers in gallium arsenide and biomedical optics. Varying the excitation wavelength can be used to study both biological tissue and condensed matter. I altered the excitation wavelengths to be in the longer near-infrared (NIR) optical windows, in the shortwave infrared (SWIR) range, a wavelength region previously thought to be unusable for medical imaging. With this method, I acquired high …