Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Keyword
- Publication
- Publication Type
Articles 1 - 3 of 3
Full-Text Articles in Physics
Design, Fabrication And Characterization Of Micro Opto-Electro-Mechanical Systems, Darren E. Sene
Design, Fabrication And Characterization Of Micro Opto-Electro-Mechanical Systems, Darren E. Sene
Theses and Dissertations
Several micro-opto-electro-mechanical structures were designed using the Multi-User MEMS Process (MUMPS). Specific design techniques were investigated for improving the capabilities of elevating flip up structures. The integration of several flip up microoptical structures into a microoptical system was explored with emphasis on the development of a microinterferometer. The thermal effects on the Modulus of Elasticity were determined by detecting the resonant frequency for a square Flexure Beam Micromirror Device. The resonance of the device was found to match theory to within 0.1 % and the Modulus of Elasticity was found to decrease by 0.041 GPa/K from 290 to 450 K. …
Studies Of Mixing Processes In Gases And Effects On Combustion And Stability, Frank Paul Kozusko Jr.
Studies Of Mixing Processes In Gases And Effects On Combustion And Stability, Frank Paul Kozusko Jr.
Mathematics & Statistics Theses & Dissertations
Three physical models of laminar mixing of initially separated gases are studied. Two models study the effects of the mixing dynamics on the chemical reactions between the gases. The third model studies the structure and stability of a laminar mixing layer in a binary gas. The three models are:
1. Two ideal and incompressible gases representing fuel and oxidizer are initially at rest and separated across an infinite linear interface in a two dimensional system. Combustion, expected as the gases mix, will lead to a rapid rise in temperature in a localized area, i.e. ignition. The mixing of the gases …
Intercomparison Between Commercial Condensation Nucleus Counters And An Alternating Temperature Gradient Cloud Chamber, Darryl J. Alofs, C. K. Lutrus, Donald E. Hagen
Intercomparison Between Commercial Condensation Nucleus Counters And An Alternating Temperature Gradient Cloud Chamber, Darryl J. Alofs, C. K. Lutrus, Donald E. Hagen
Mechanical and Aerospace Engineering Faculty Research & Creative Works
Three Commercial CNC Counters (TSI Models 3010, 3022A, and 3025A) Are Compared with an Alternating Temperature Gradient Cloud Chamber (ALGR). Electrically Size Classified Aerosols of Sodium Chloride and Silver Are Used. Diffusional Losses within the ALGR Are Much Larger Than for the TSI Instruments: Therefore the ALGR Concentrations Are Corrected for Internal Diffusional Losses, But the TSI Instruments Are Not. the Particle Size Range Tested is 4–90 Nm. for Sodium Chloride, the TSI Concentrations Agreed Fairly Well with the Corrected ALGR at Larger Sizes, and Were Below the Corrected ALGR at Smaller Sizes. the Electrical Aerosol Classifier (EAC) Setting at …