Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Institution
- Keyword
- Publication
- Publication Type
Articles 1 - 4 of 4
Full-Text Articles in Materials Chemistry
Design Of A Viscometer Using Magnetostriction Of Ferromagnetic Probes, Subhendra Nath Sarkar
Design Of A Viscometer Using Magnetostriction Of Ferromagnetic Probes, Subhendra Nath Sarkar
Journal of the Arkansas Academy of Science
On-line measurement of viscosity of process liquids at process temperature is difficult though industrially very important. A viscometer is designed which can do this up to about 300 °C almost on-line within about 1-8% accuracy except for very viscous liquids like glucose. It uses a ferromagnetic probe designed to mechanically vibrate in the ultrasonic frequency range. An excitation coil sends repeated excitation current pulses to induce mechanical vibration in the probe tip. When placed in a process fluid, the vibration amplitude is damped due to the viscosity of the fluid, and the damped vibration is sensed by Faraday's principle by …
Coincidence Orientations Of Crystals In Tetragonal Systems, With Applications To Yba2cu3o7, Abha Singh, N. Chandrasekhar, Alexander H. King
Coincidence Orientations Of Crystals In Tetragonal Systems, With Applications To Yba2cu3o7, Abha Singh, N. Chandrasekhar, Alexander H. King
Alexander H. King
We have developed a method for the characterization of coincidence-site lattices (CSL's) in tetragonal or near-tetragonal orthorhombic structures, by suitable modifications to the method of Grimmer & Warrington [Acta Cryst. (1987), A43, 232-243]. We have applied our method to determine coincidence rotations and the associated information appropriate for forming constrained CSL's in the high-To superconductor YBazCu307-n. The unit cell is orthorhombic with lattice parameters a = 3.82, b = 3"89 and c = 11.67 A for the nominal composition. We present tables of coincidence rotation angles, .Z, CSL, DSCL and associated step vectors up to ,~ = 50. We find …
Rheology Of Aqueous Suspensions Of Polystyrene Latex Stabilized By Grafted Poly(Ethylene Oxide), Harry J. Ploehn, J. W. Goodwin
Rheology Of Aqueous Suspensions Of Polystyrene Latex Stabilized By Grafted Poly(Ethylene Oxide), Harry J. Ploehn, J. W. Goodwin
Faculty Publications
A water-soluble carbodiimide has been used to end-graft aminated poly (ethylene oxide)(PEO) chemically onto colloidal polystyrene particles. Two particle sizes (115 and 347 nm diameter) and two PEO molecular weights (112 000 and 615 000 g mol–1) were combined to give suspensions with four different ratios of polymer layer thickness to particle radius. Electrophoresis demonstrated that the PEO was grafted, not just adsorbed. Dynamic light scattering showed that the adsorbed and grafted layers had similar structures and that non-ionic surfactant perturbed the PEO configurations. Steady shear and oscillatory rheometry indicated that long-ranged polymeric forces between particles governed the …
A Warning For The Wagner Polarization Cell, Michael Setter, J. Akridge, M. Balkanski
A Warning For The Wagner Polarization Cell, Michael Setter, J. Akridge, M. Balkanski
Michael P. Setter
No abstract provided.