Full-Text Articles in Surgical Procedures, Operative

Biomechanical Analysis Of Ligament Modelling Techniques And Femoral Component Malrotation Following Tka, Liam A. Montgomery Dec 2021

Biomechanical Analysis Of Ligament Modelling Techniques And Femoral Component Malrotation Following Tka, Liam A. Montgomery

Electronic Thesis and Dissertation Repository

Previous studies have demonstrated that satisfaction and revision rates following total knee arthroplasty (TKA) are lower than those of comparable surgeries such as total hip replacements. A leading cause for these revisions is joint instability which may be due to improper ligament balancing or poorly aligned surgical implants. One of the methods used to investigate biomechanical forces and kinematics is computational modelling of the post-operative TKA knee.

A unique knee model was used to investigate the biomechanical and kinematic effects of ligament model complexity, as well as the effects of simulating ligament wrapping versus ignoring ligament wrapping. We then used …


Non-Invasive Peripheral Venous And Arterial Line Air Detector For Embolization Prevention, Alexandria Kwong, Kevin Shu, Dylan Meinster Jun 2020

Non-Invasive Peripheral Venous And Arterial Line Air Detector For Embolization Prevention, Alexandria Kwong, Kevin Shu, Dylan Meinster

Biomedical Engineering

The scope of this project includes designing a non-invasive bubble detector for peripheral venous and arterial lines. For minimally invasive cardiac procedures, arterial and venous access is necessary for these procedures as is constant flow through the tubing to prevent clotting and to administer drugs. Air bubbles are common in these lines and can be consequential if enough air is introduced into the human system. Air embolisms are the most common and relevant issues during these procedures. The goal of this device is to create an attachable detector for air bubbles in saline that can also terminate flow and alert …


Sol Retractor: Rapidly Deployable Film-Based C-Section Retractor, Casey Lee, Silas Cleveland, Jose Dolores Valdivieso, Joseph Perks Jun 2020

Sol Retractor: Rapidly Deployable Film-Based C-Section Retractor, Casey Lee, Silas Cleveland, Jose Dolores Valdivieso, Joseph Perks

Honors Theses

Cesarean Sections (C-sections), a surgery conducted for baby delivery, can be divided into four distinct categories; Category 1 and 2 are considered emergency c-sections, and Category 3 and 4 are scheduled c-sections [2]. A comparative study from 2016 analyzed the difference of need for postoperative treatment between the Collins or the Alexis O retractor ( n = 100). The Alexis O C-Section retractor resulted in 19% of women requiring postoperative treatment, including medication, monitoring, and an extended stay at the hospital. The Collins resulted in 43% of the patients requiring postoperative treatment (p = 0.001) [5]. In emergency C-sections, surgical …


Tibiotalar Arthrodesis: Development Of A Novel Jig And Alignment Guide, Adam Mathew Ropchan Nov 2018

Tibiotalar Arthrodesis: Development Of A Novel Jig And Alignment Guide, Adam Mathew Ropchan

Electronic Thesis and Dissertation Repository

Tibiotalar arthrodesis is a surgical procedure, used for the treatment of end-stage ankle arthrosis and instability. There are dozens of described procedures in the literature, all with varying rates of success. Two of the most common reasons for reoperation in tibiotalar arthrodesis are nonunion and infection; few studies have established any associations between patient/surgical factors and reoperation for nonunion and infection.

The first part of this thesis focuses on determining the rate of reoperation to the ipsilateral lower limb and if any patient/surgical factors are associated with reoperation for nonunion and infection. The second part of this thesis turns attention …


A Novel Hybrid Imaging System To Aid In Surgical Decision Making, Lawrence Yip, Madeleine Van De Kleut, Ivan Kosik, Astrid Chamson-Reig, Jeffrey Jl Carson Mar 2017

A Novel Hybrid Imaging System To Aid In Surgical Decision Making, Lawrence Yip, Madeleine Van De Kleut, Ivan Kosik, Astrid Chamson-Reig, Jeffrey Jl Carson

Western Research Forum

Background:

Breast cancer accounts for 25% of all cancer cases among women. In breast-conserving surgery, a common treatment, the tumour is excised with a healthy tissue margin. However, detection of the margin can be difficult. Current techniques to guide excision are often insufficient, and re-excision can occur up to 25% of the time.

Methods:

Photoacoustic imaging is a hybrid imaging modality that combines the advantages of optical imaging and ultrasound while using safe non-ionizing light. This project involves the development of a novel imaging system with a new scanner design to overcome common limitations and provide images to aid in …


Utility Of Ultrasound/Photoacoustic Imaging For Accurate Catheter Tracking And Temperature Monitoring During Endovenous Laser Ablation, Ayushi Jharia, Keerthana Palani, Yan Yan Jan 2017

Utility Of Ultrasound/Photoacoustic Imaging For Accurate Catheter Tracking And Temperature Monitoring During Endovenous Laser Ablation, Ayushi Jharia, Keerthana Palani, Yan Yan

Research Opportunities for Engineering Undergraduates (ROEU) Program 2016-17

Laser ablation is a treatment method that uses light energy through a catheter inserted into a vein to induce localized heat to close the diseased blood vessels. Ultrasound (US) imaging has been used for catheter visualization and tracking. US has limitations for tracking the accurate location of the fiber tip inside small perforating veins such as angular dependency and comet tail artifacts. We propose a robust and accurate method for fiber tip tracking using combined US and Photoacoustic (PA) imaging to overcome the existing limitations.


Neurosurgical Ultrasound Pose Estimation Using Image-Based Registration And Sensor Fusion - A Feasibility Study, Utsav Pardasani Oct 2016

Neurosurgical Ultrasound Pose Estimation Using Image-Based Registration And Sensor Fusion - A Feasibility Study, Utsav Pardasani

Electronic Thesis and Dissertation Repository

Modern neurosurgical procedures often rely on computer-assisted real-time guidance using multiple medical imaging modalities. State-of-the-art commercial products enable the fusion of pre-operative with intra-operative images (e.g., magnetic resonance [MR] with ultrasound [US] images), as well as the on-screen visualization of procedures in progress. In so doing, US images can be employed as a template to which pre-operative images can be registered, to correct for anatomical changes, to provide live-image feedback, and consequently to improve confidence when making resection margin decisions near eloquent regions during tumour surgery.

In spite of the potential for tracked ultrasound to improve many neurosurgical procedures, it …


Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka Aug 2014

Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Paradigm shifts in invasiveness, recovery time, cosmesis, and cost have been seen within the field of general surgery through major advances in surgical technology. Some of the most advanced types of general surgery now include Minimally Invasive Surgery (MIS), LaparoEndoscopic Single-Site (LESS) surgery, and Natural Orifice Translumenal Endoscopic Surgery (NOTES). One of the newest and rapidly developing catalysts is robotic platforms. Such platforms have improved ergonomics and control, increased workspace and dexterity, and have surpassed the efficacy of many non-robotic platforms such as traditional laparoscopic surgical tools. This thesis presents the design and development of a four-degree-of-freedom (4- DOF) miniature …


Evaluating Human Performance For Image-Guided Surgical Tasks, Matthew Kenneth Kramers Aug 2014

Evaluating Human Performance For Image-Guided Surgical Tasks, Matthew Kenneth Kramers

Electronic Thesis and Dissertation Repository

The following work focuses on the objective evaluation of human performance for two different interventional tasks; targeted prostate biopsy tasks using a tracked biopsy device, and external ventricular drain placement tasks using a mobile-based augmented reality device for visualization and guidance. In both tasks, a human performance methodology was utilized which respects the trade-off between speed and accuracy for users conducting a series of targeting tasks using each device. This work outlines the development and application of performance evaluation methods using these devices, as well as details regarding the implementation of the mobile AR application. It was determined that the …


Fluid Powered Miniature In-Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat Aug 2014

Fluid Powered Miniature In-Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Minimizing the invasiveness of surgery is believed to improve patient outcomes. Bleeding, infection, and pain are major concerns in surgery afflicting patients for decades. Minimally invasive techniques have come into play to reduce these concerns and smooth the evolution of abdominal surgery to a scarless process where nearly all surgeries can be performed without a skin incision. Technology continually advances the frontier of development of novel surgical devices to implement less invasive surgical techniques.

Fusion of robotics and Minimally Invasive Surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems …


Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas Feb 2014

Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas

Publications and Research

Introduction. In medically refractory Parkinson’s disease (PD) deep-brain stimulation (DBS) is an effective therapeutic tool. Postimplantation MRI is important in assessing tissue damage and DBS lead placement accuracy. We wanted to identify which MRI sequence can detectDBS leads with smallest artifactual signal void, allowing better tissue/electrode edge conspicuity.

Methods. Using an IRB approved protocol 8 advanced PDpatientswere imagedwithinMRconditional safety guidelines at lowRF power (SAR ≤ 0.1 W/kg) in coronal plane at 1.5T by various sequences.The image slices were subjectively evaluated for diagnostic quality and the lead contact diameters were compared to identify a sequence least affected by metallic leads.

Results …


A Novel Signal Processing Method For Intraoperative Neurophysiological Monitoring In Spinal Surgeries, Krishnatej Vedala Nov 2013

A Novel Signal Processing Method For Intraoperative Neurophysiological Monitoring In Spinal Surgeries, Krishnatej Vedala

FIU Electronic Theses and Dissertations

Intraoperative neurophysiologic monitoring is an integral part of spinal surgeries and involves the recording of somatosensory evoked potentials (SSEP). However, clinical application of IONM still requires anywhere between 200 to 2000 trials to obtain an SSEP signal, which is excessive and introduces a significant delay during surgery to detect a possible neurological damage. The aim of this study is to develop a means to obtain the SSEP using a much less, twelve number of recordings. The preliminary step involved was to distinguish the SSEP with the ongoing brain activity. We first establish that the brain activity is indeed quasi-stationary whereas …


An Assessment Of Novel Biodegradable Magnesium Alloys For Endovascular Biomaterial Applications, Dharam Persaud-Sharma Jun 2013

An Assessment Of Novel Biodegradable Magnesium Alloys For Endovascular Biomaterial Applications, Dharam Persaud-Sharma

FIU Electronic Theses and Dissertations

Magnesium alloys have been widely explored as potential biomaterials, but several limitations to using these materials have prevented their widespread use, such as uncontrollable degradation kinetics which alter their mechanical properties. In an attempt to further the applicability of magnesium and its alloys for biomedical purposes, two novel magnesium alloys Mg-Zn-Cu and Mg-Zn-Se were developed with the expectation of improving upon the unfavorable qualities shown by similar magnesium based materials that have previously been explored. The overall performance of these novel magnesium alloys has been assessesed in three distinct phases of research: 1) analysing the mechanical properties of the as-cast …