A Quantitative Dosimetric Comparison Of Dibh Vmat And Static-Imrt Apbi Treatments: Evaluating Large Left Sided Lumpectomy Cavities Located Near The Chest Wall, Christopher Jordan Clifton Jul 2023

A Quantitative Dosimetric Comparison Of Dibh Vmat And Static-Imrt Apbi Treatments: Evaluating Large Left Sided Lumpectomy Cavities Located Near The Chest Wall, Christopher Jordan Clifton

Culminating Experience Projects

Abstract

Introduction

The main purpose of this study was to determine whether there was a significant difference between the dose distributions when comparing static-IMRT and VMAT plans for patients with large left sided lumpectomy cavities located near the chest wall while utilizing DIBH. Thorough planning and statistical analysis was performed to determine whether there was a clear advantage for either treatment technique to better benefit patient outcomes.

Methods

Ten female patients with large left sided lumpectomy cavities were selected to be retrospectively planned using both static-IMRT and VMAT plans. Each patient fell within the ASTRO eligibility criteria for APBI treatments. …


Validation Of A Respiratory Gating System For Automated Delivery Of The Deep Inspiration Breath-Hold Technique, Michael G. Stock May 2021

Validation Of A Respiratory Gating System For Automated Delivery Of The Deep Inspiration Breath-Hold Technique, Michael G. Stock

LSU Master's Theses

Purpose: To validate the performance of a respiratory gating system for the automated delivery of the deep inspiration breath-hold (DIBH) technique.

Methods: The gating system utilized an automatic gating interface (Elekta Response) which connected a marker-based respiratory motion monitoring system to the linear accelerator control system. The gating system was characterized dosimetrically and temporally using two distinct approaches. Central-axis output and energy constancy were evaluated across 8 beam-matched linear accelerators. Additionally, a representative set of 5 treatment plans were delivered both non-gated and gated to a 2D diode array (MapCHECK). The respiratory motion monitoring system optically tracked a reflective marker …


Optimizing Heart Dose Reduction For Deep Inspiration Left Breast Radiotherapy, Ronald James Harder Dec 2011

Optimizing Heart Dose Reduction For Deep Inspiration Left Breast Radiotherapy, Ronald James Harder

UNLV Theses, Dissertations, Professional Papers, and Capstones

Multiple studies have shown that an increased risk of late injury cardiac abnormalities including congestive heart failure (CHF), ischemia, and coronary artery disease (CAD) can be associated with common left breast radiation therapy (RT) techniques. Many radiation therapy clinics have adopted the Deep Inspiration Breath Hold (DIBH) technique for the treatment of the left breast with external beam therapy based on studies showing a decrease in the dose received by the heart. A common technology used to monitor inhalation during DIBH is the Real-Time Position Management (RPM) system (Varian Medical Systems, Palo Alto, CA). This study analyzes if there is …