Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Medicine and Health Sciences

Separation Of Turkey Heterophils From Blood Using Two-Step Ficoll-Hypaque Discontinuous Gradients, Kenneth S. Latimer, Ingrid M. Kircher, Claire B. Andreasen Jan 1989

Separation Of Turkey Heterophils From Blood Using Two-Step Ficoll-Hypaque Discontinuous Gradients, Kenneth S. Latimer, Ingrid M. Kircher, Claire B. Andreasen

Claire B. Andreasen

A method is presented to separate turkey heterophils from anticoagulated whole blood using two-step Ficoll-Hypaque discontinuous gradients and ammonium chloride lysis of contaminating erythrocytes. Heterophils can be isolated from multiple blood samples within 3 to 4 hours. Using this technique, 66.4 +- 18.4% (mean +- standard deviation) of blood heterophils were harvested. Final cell isolates averaged 96.0 +- 2.9% heterophils with few contaminating eosinophils (2.5 +- 2.3%) or basophils (1.6 +- 1.8%). Cell viability, as determined by trypan blue dye exclusion, was 98.0 +- 1.4%.


Determination Of Chicken And Turkey Plasma And Serum Protein Concentrations By Refractometry And The Biuret Method, Claire B. Andreasen, Kenneth S. Latimer, Ingrid M. Kircher, John Brown Jan 1989

Determination Of Chicken And Turkey Plasma And Serum Protein Concentrations By Refractometry And The Biuret Method, Claire B. Andreasen, Kenneth S. Latimer, Ingrid M. Kircher, John Brown

Claire B. Andreasen

Plasma and serum protein concentrations were determined in chickens and turkeys by refractometry (with human and veterinary refractometers)and by the biuret method. Chicken and turkey serum protein values were significantly lower than respective plasma protein values according to both methods. Refractometer readings for both plasma and serum correlated closely with the results of the biuret test (r2 = 0.72 to 0.97). These findings indicate that plasma and serum protein values may be determined accurately in chickens and turkeys with a handheld refractometer.


Separation Of Avian Heterophils From Blood Using Ficoll-Hypaque Discontinuous Gradients, Claire B. Andreasen, Kenneth S. Latimer Jan 1989

Separation Of Avian Heterophils From Blood Using Ficoll-Hypaque Discontinuous Gradients, Claire B. Andreasen, Kenneth S. Latimer

Claire B. Andreasen

Rapid separation of avian heterophils from anticoagulated whole blood was achieved using Ficoll-Hypaque discontinuous gradients. An average of 14.4% of blood heterophils was harvested with a mean purity exceeding 99%. Heterophil viability, as determined by trypan blue dye exclusion, averaged 99.8%. The integrity of isolated heterophils was evaluated by cytochemical staining and ultrastructural examination. Cytochemical staining reactions of heterophils in whole blood and of isolated cell suspensions were similar. No ultrastructural abnormalities were observed. Using this procedure, viable intact heterophils were rapidly isolated from blood with an acceptable cell yield and purity for cell function studies.