The Correlation Between The Levels Of Education Of Clinical Laboratory Personnel And The Accuracy Of Peripheral Blood Smear Results, Susan J. Leclair Jan 2001

The Correlation Between The Levels Of Education Of Clinical Laboratory Personnel And The Accuracy Of Peripheral Blood Smear Results, Susan J. Leclair

Walden Dissertations and Doctoral Studies

This study correlated the performance accuracy of peripheral blood differentials evaluated by clinical laboratory scientists and clinical laboratory technicians. Fifty-one senior-year students from four clinical laboratory science baccalaureate programs and 37 second-year students from five clinical laboratory technician programs were given 10 peripheral blood differentials to perform. Results were compared to the values assigned by the Rajamaki method of proficiency testing. There was a significant discrepancy in the levels of accuracy between the two cohorts, suggesting that the results of peripheral blood differentials performed by clinical laboratory technicians is suspect. Facilities wishing to maintain or improve the quality of laboratory …