Open Access. Powered by Scholars. Published by Universities.®

Biomechanics Commons

Open Access. Powered by Scholars. Published by Universities.®

Mechanical and Aerospace Engineering Faculty Publications

Articles 1 - 17 of 17

Full-Text Articles in Biomechanics

Development Of A Muscle Model Parameter Calibration Method Via Passive Muscle Force Minimization, Allison Kinney, Benjamin J. Fregly Jul 2015

Development Of A Muscle Model Parameter Calibration Method Via Passive Muscle Force Minimization, Allison Kinney, Benjamin J. Fregly

Mechanical and Aerospace Engineering Faculty Publications

Computational predictions of subject-specific muscle and knee joint contact forces during walking may improve individual rehabilitation treatment design. Such predictions depend directly on specified model parameter values. However, model parameters are difficult to measure non-invasively. Methods for muscle model parameter calibration have been developed previously. However, it is currently unknown how the musculoskeletal system chooses muscle model parameter values. Previous studies have hypothesized that muscles avoid injury during walking by generating little passive force and operating in the ascending region of the force-length curve. This hypothesis suggests that muscle model parameter values may be selected by the body to minimize …


Synergy-Based Two-Level Optimization For Predicting Knee Contact Forces During Walking, Gil Serrancolí, Allison Kinney, Josep M. Font-Llagunes, Benjamin J. Fregly Jul 2015

Synergy-Based Two-Level Optimization For Predicting Knee Contact Forces During Walking, Gil Serrancolí, Allison Kinney, Josep M. Font-Llagunes, Benjamin J. Fregly

Mechanical and Aerospace Engineering Faculty Publications

Musculoskeletal models and optimization methods are combined to calculate muscle forces. Some model parameters cannot be experimentally measured due to the invasiveness, such as the muscle moment arms or the muscle and tendon lengths. Moreover, other parameters used in the optimization, such as the muscle synergy components, can be also unknown. The estimation of all these parameters needs to be validated to obtain physiologically consistent results. In this study, a two-step optimization problem was formulated to predict both muscle and knee contact forces of a subject wearing an instrumented knee prosthesis. In the outer level, muscle parameters were calibrated, whereas …


The Influence Of Neuromusculoskeletal Model Calibration Method On Predicted Knee Contact Forces During Walking, Gil Serrancolí, Allison Kinney, Benjamin J. Fregly, Josep M. Font-Llagunes Jun 2015

The Influence Of Neuromusculoskeletal Model Calibration Method On Predicted Knee Contact Forces During Walking, Gil Serrancolí, Allison Kinney, Benjamin J. Fregly, Josep M. Font-Llagunes

Mechanical and Aerospace Engineering Faculty Publications

This study explored the influence of three model calibration methods on predicted knee contact and leg muscle forces during walking. Static optimization was used to calculate muscle activations for all three methods. Approach A used muscle-tendon model parameter values (i.e., optimal muscle fiber lengths and tendon slack lengths) taken directly from literature. Approach B used a simple algorithm to calibrate muscle-tendon model parameter values such that each muscle operated within the ascending region of its normalized force-length curve. Approach C used a novel two-level optimization procedure to calibrate muscle-tendon, moment arm, and neural control model parameter values while simultaneously predicting …


A Multi-Directional Treadmill Training Program For Improving Gait, Balance, And Mobility In Individuals With Parkinson’S Disease: A Case Series, Kimberly Smith, Kurt Jackson, Kimberly Edginton Bigelow, Lloyd L. Laubach Jan 2015

A Multi-Directional Treadmill Training Program For Improving Gait, Balance, And Mobility In Individuals With Parkinson’S Disease: A Case Series, Kimberly Smith, Kurt Jackson, Kimberly Edginton Bigelow, Lloyd L. Laubach

Mechanical and Aerospace Engineering Faculty Publications

Treadmill training is a commonly used intervention for improving gait in people with Parkinson’s disease (PD). However, little is known about how treadmill training may also influence balance and other aspects of mobility.

The purpose of this case series was to explore the feasibility and possible benefits of multi-directional treadmill training for individuals with PD. Four participants (62.3 ± 6.5 yrs, Hoehn & Yahr 2-4) performed 8 weeks of treadmill training 3 times per week. Weeks 1-4 included forward walking only, while weeks 5-8 included forward and multi-directional walking. Participants were tested every 4 weeks on 4 separate occasions. Outcome …


How Sensitive Is The Deltoid Moment Arm To Joint Center Changes With Rtsa?, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks Sep 2014

How Sensitive Is The Deltoid Moment Arm To Joint Center Changes With Rtsa?, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks

Mechanical and Aerospace Engineering Faculty Publications

The goal of this study was to assess the sensitivity of the deltoid muscle moment arms as a function of joint configuration for an existing RTSA subject. High variations were found for all three deltoid components. Variation over the entire abduction arc was greatest in the anterior and lateral deltoid, while the posterior deltoid moment arm was mostly sensitive to joint center changes early in the abduction arc. Moment arm changes of 10-16mm represent a significant amount of the total deltoid moment arm. This means there is an opportunity to dramatically change the deltoid moments arms through surgical placement of …


Deltoid Moment Arms During Abduction: A Subject-Specific Musculoskeletal Modeling Study In Healthy Shoulders And Shoulders With Rtsa, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks Sep 2014

Deltoid Moment Arms During Abduction: A Subject-Specific Musculoskeletal Modeling Study In Healthy Shoulders And Shoulders With Rtsa, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks

Mechanical and Aerospace Engineering Faculty Publications

Reverse total shoulder arthroplasty (RTSA) is increasingly used in the United States since approval by the FDA in 2003. RTSA relieves pain and restores mobility in arthritic rotator cuff deficient shoulders. Though many advantages of RTSA have been demonstrated, there still are a variety of complications (implant loosening, shoulder impingement, infection, frozen shoulder) making apparent much still is to be learned how RTSA modifies normal shoulder function. The goal of this study was to assess how RTSA affects deltoid muscle moment generating capacity post-surgery using a subjectspecific computational model driven by in vivo kinematic data.


A Novel Approach To Estimation Of Patient-Specific Muscle Strength, David Walker, Allison Kinney, Benjamin J. Fregly, Thomas Wright, Scott Banks Sep 2014

A Novel Approach To Estimation Of Patient-Specific Muscle Strength, David Walker, Allison Kinney, Benjamin J. Fregly, Thomas Wright, Scott Banks

Mechanical and Aerospace Engineering Faculty Publications

Current modeling techniques have been used to model the Reverse Total Shoulder Arthroplasty (RTSA) to account for the geometric changes implemented after RTSA. Though these models have provided insight into the effects of geometric changes from RTSA these is still a limitation of understanding muscle function after RTSA on a patient-specific basis. The goal of this study sought to overcome this limitation by developing an approach to calibrate patient-specific muscle strength for an RTSA subject.


Formulation To Predict Lower Limb Muscle Forces During Gait, Gil Serrancolí, Jonathan P. Walter, Allison Kinney, A. Barjau, Benjamin J. Fregly, Josep M. Font-Llagunes Oct 2013

Formulation To Predict Lower Limb Muscle Forces During Gait, Gil Serrancolí, Jonathan P. Walter, Allison Kinney, A. Barjau, Benjamin J. Fregly, Josep M. Font-Llagunes

Mechanical and Aerospace Engineering Faculty Publications

The human body has more muscles than Degrees of Freedom (DoF), and that leads to indeterminacy in the muscle force calculation. This study proposes the formulation of an optimization problem to estimate the lower-limb muscle forces during a gait cycle of a patient wearing an instrumented knee prosthesis. The originality of that formulation consists of simulating muscle excitations in a physiological way while muscle parameters are calibrated. Two approaches have been considered. In Approach A, measured contact forces are applied to the model and all inverse dynamics loads are matched in order to get a physiological calibration of muscle parameters. …


Optimization Problem Formulation For Predicting Knee Muscle And Contact Forces During Gait, Gil Serrancolí, Jonathan P. Walter, Allison Kinney, Benjamin J. Fregly, Josep M. Font-Llagunes Aug 2013

Optimization Problem Formulation For Predicting Knee Muscle And Contact Forces During Gait, Gil Serrancolí, Jonathan P. Walter, Allison Kinney, Benjamin J. Fregly, Josep M. Font-Llagunes

Mechanical and Aerospace Engineering Faculty Publications

The human body has more muscles than degrees of freedom (DOF), which leads to indeterminacy in the muscle force calculation. In this study, an optimization problem to estimate the lower-limb muscle forces during a gait cycle of a patient wearing an instrumented knee prosthesis is formulated. It consists of simulating muscle excitations in a physiological way while muscle parameters are calibrated.


Changes In In Vivo Knee Contact Forces Through Gait Modification, Allison Kinney, Thor F. Besier, Amy Slider, Scott L. Delp, Darryl D. D'Lima, Benjamin J. Fregly Aug 2012

Changes In In Vivo Knee Contact Forces Through Gait Modification, Allison Kinney, Thor F. Besier, Amy Slider, Scott L. Delp, Darryl D. D'Lima, Benjamin J. Fregly

Mechanical and Aerospace Engineering Faculty Publications

Gait modification represents a non-invasive method for reducing knee joint loading in patients with knee osteoarthritis. Previous studies have shown that a variety of gait modifications are effective in reducing the external knee adduction moment. The external knee adduction moment is often used as a surrogate measure of medial compartment force. However, a recent study showed that reductions in the external knee adduction moment do not guarantee reductions in medial compartment loads. Therefore, direct measurement of changes in knee contact force is important for determining the effectiveness of gait modifications. A previous study found that medial thrust gait and walking …


Effectiveness Of Group Kickboxing As A Means To Improve Gait And Balance In Individuals With Ms, Kurt Jackson, Kimberly Edginton Bigelow, Christina Cooper, Harold L. Merriman Oct 2011

Effectiveness Of Group Kickboxing As A Means To Improve Gait And Balance In Individuals With Ms, Kurt Jackson, Kimberly Edginton Bigelow, Christina Cooper, Harold L. Merriman

Mechanical and Aerospace Engineering Faculty Publications

In recent years, there has been a particular emphasis on identifying and delivering appropriate therapeutic interventions that address the significant balance and gait impairments that affect individuals with multiple sclerosis (MS). Group interventions implemented in community settings have been especially of interest, including tai chi classes. Recently, the authors conducted a preliminary study to examine whether group kick-boxing, which requires more vigorous movements, might be a feasible intervention. Initial findings showed promise and led the authors to pursue a more rigorous follow-up study, with the objective of determining whether a 5-week group kickboxing class improved clinical measures of balance and …


Muscle Contributions To Frontal And Transverse Plane Whole-Body Angular Momentum, Richard R. Neptune, Craig P. Mcgowan, Allison Kinney Jul 2011

Muscle Contributions To Frontal And Transverse Plane Whole-Body Angular Momentum, Richard R. Neptune, Craig P. Mcgowan, Allison Kinney

Mechanical and Aerospace Engineering Faculty Publications

The purpose of this study was to build upon previous work by analyzing how gravity and individual muscles contribute to frontal and traverse plane whole-body angular momentum. Identifying which muscles are responsible for generating angular momentum has important implications for the diagnosis and treatment of movement disorders.


Pre-Swing Deficits In Forward Propulsion, Swing Initiation And Power Generation By Individual Muscles In Hemiparetic Walking, Carrie L. Peterson, Allison Kinney, Steven A. Kautz, Richard R. Neptune Aug 2010

Pre-Swing Deficits In Forward Propulsion, Swing Initiation And Power Generation By Individual Muscles In Hemiparetic Walking, Carrie L. Peterson, Allison Kinney, Steven A. Kautz, Richard R. Neptune

Mechanical and Aerospace Engineering Faculty Publications

Clinical studies of hemiparetic walking have shown pre-swing abnormalities in the paretic leg suggesting that paretic muscle contributions to important biomechanical walking subtasks are different than those of non-disabled individuals. Three-dimensional forward dynamics simulations of two representative hemiparetic subjects with different levels of walking function classified by self-selected walking speed (i.e., limited community=0.4–0.8 m/s and community walkers=>0.8 m/s) and a speed-matched control were generated to quantify individual muscle contributions to forward propulsion, swing initiation and power generation during the pre-swing phase (i.e., double support phase proceeding toe-off). Simulation analyses identified decreased paretic soleus and gastrocnemius contributions to forward propulsion …


Relationships Between Muscle Contributions To Walking Subtasks And Functional Walking Status In Persons With Post-Stroke Hemiparesis, Allison Kinney, Carrie L. Peterson, Steven A. Kautz, Richard R. Neptune Aug 2010

Relationships Between Muscle Contributions To Walking Subtasks And Functional Walking Status In Persons With Post-Stroke Hemiparesis, Allison Kinney, Carrie L. Peterson, Steven A. Kautz, Richard R. Neptune

Mechanical and Aerospace Engineering Faculty Publications

Walking speed is commonly used to predict stroke severity and assess functional walking status (i.e., household, limited community and community walking status) post-stroke. The underlying mechanisms that limit walking speed (and functional walking status by extension) need to be understood to improve post-stroke rehabilitation. Previous experimental studies have shown correlations between paretic plantarflexor output during the pre-swing phase and walking speed and suggest that the paretic hip flexors can compensate in some hemiparetic subjects. Modeling and simulation studies of healthy walking have shown that the ankle plantarflexors, soleus (SOL) and gastrocnemius (GAS), and uniarticular hip flexors (IL) are essential contributors …


Development And Analysis Of A Software Package To Quantify In Vivo Polyethylene Wear After Total Hip Arthroplasty, Allison Kinney, Catherine G. Ambrose Jul 2007

Development And Analysis Of A Software Package To Quantify In Vivo Polyethylene Wear After Total Hip Arthroplasty, Allison Kinney, Catherine G. Ambrose

Mechanical and Aerospace Engineering Faculty Publications

Since the first total hip arthroplasty (THA) in 1938, THA evolved and developed into one of the major concentrations of orthopaedic research. The typical hip implant device used today incorporates a femoral and an acetabular component that serve to replicate the anatomical and mechanical functions of the natural hip joint. However, several problems exist that can effect the function of the implant device. Wear in the polyethylene liner of the acetabular component of the total hip replacement device is known as one of the major factors that affects the longevity of total hip replacement devices. Both manual and computer-aided techniques …


Fabrication Of Ankle-Foot Orthoses Using Selective Laser Sintering Technology, Allison Kinney, M. C. Faustini, Richard R. Neptune, R. H. Crawford, S. J. Stanhope Jul 2007

Fabrication Of Ankle-Foot Orthoses Using Selective Laser Sintering Technology, Allison Kinney, M. C. Faustini, Richard R. Neptune, R. H. Crawford, S. J. Stanhope

Mechanical and Aerospace Engineering Faculty Publications

Passive dynamic ankle-foot orthoses (AFOs) are often prescribed to improve gait performance for those with various neuromuscular disorders. Designs and materials used for AFOs range from simple polypropylene braces to advanced custom carbon fiber dynamic AFOs that passively store and release mechanical energy during gait. AFO designs vary in the shape and length of the foot component as well as the stiffness and length of the tibial component, depending on the desired functional outcomes. However, the current fabrication technology is not ideally suited for refined customization of AFO characteristics to optimize performance, or for rapid lowcost, high volume manufacturing and …


Microscale Investigation Of Thermo-Fluid Transport In The Transition Fil, Region Of An Evaporating Capillary Meniscus Using A Microgravity Environment, Kenneth D. Kihm, Jeffrey S. Allen, Kevin P. Hallinan, David M. Pratt Jan 2004

Microscale Investigation Of Thermo-Fluid Transport In The Transition Fil, Region Of An Evaporating Capillary Meniscus Using A Microgravity Environment, Kenneth D. Kihm, Jeffrey S. Allen, Kevin P. Hallinan, David M. Pratt

Mechanical and Aerospace Engineering Faculty Publications

In order to enhance the fundamental understanding of thin film evaporation and thereby improve the critical design concept for two-phase heat transfer devices, microscale heat and mass transport is to be investigated for the transition film region using state-of-the-art optical diagnostic techniques. By utilizing a microgravity environment, the length scales of the transition film region can be extended sufficiently, from submicron to micron, to probe and measure the microscale transport fields which are affected by intermolecular forces. Extension of the thin film dimensions under microgravity will be achieved by using a conical evaporator made of a thin silicon substrate under …