Life Safety Code

2016

Articles 1 - 5 of 5

Full-Text Articles in Other Engineering

Office Building- Fire Protection Systems Evaluation, Christine Newton Jun 2016

Office Building- Fire Protection Systems Evaluation, Christine Newton

Fire Protection Engineering: Culminating Experience Project Reports

This report is a Life Safety Code (LSC) and fire protection systems evaluation of an office building located in Colorado. This report covers the prescriptive analysis of the building, as well as the performance‐based aspect of the evaluation.

The prescriptive analysis of this report includes assessment of the building code for structural design, means of egress, detection and notification systems, smoke control system, and the water‐ based fire suppression system for this building. The 2012 International Building Code (IBC) and the National Fire Protection Agency (NFPA) 101 LSC were used for the prescriptive based evaluation and the building was determined …


Sheraton Hotel- Life Safety Report, Raul M. Farfan Jun 2016

Sheraton Hotel- Life Safety Report, Raul M. Farfan

Fire Protection Engineering: Culminating Experience Project Reports

This report evaluates the prescriptive life safety requirements for levels one (1) through four (4) of the Sheraton Hotel in downtown Phoenix. In addition, this report discusses two fire scenarios that evaluate the tenability during egress the in pre-function area on level two (2) and in the main ballroom on level three (3) of the hotel.

The prescriptive standards/codes used to evaluate the hotel are the International Building Code (IBC), International Fire Code (IFC), and applicable standards from the National Fire Protection Association (NFPA). Performance based analysis were conducted using Pathfinder, CFast, and Fire Dynamic Simulator (FDS). Two fire scenarios …


Analysis Of Costco, San Francisco, Ian Levine Jun 2016

Analysis Of Costco, San Francisco, Ian Levine

Fire Protection Engineering: Culminating Experience Project Reports

This report provides an in-depth analysis of the fire safety systems and design considerations of the Costco store located at 450 10th Street in San Francisco, California, satisfying the requirements for completion of the FPE 596 – Culminating Experience in Fire Protection Engineering academic series. The building is introduced, followed by an analysis of the building structure, alarm and detection, egress, and sprinkler systems are designed based on prescriptive code. These systems are then analyzed from a performance based perspective to gain understanding of how the systems will respond to a challenging design fire. Their response is used to determine …


Eric W. Rood Administration Center- Fire Protection And Life Safety Analysis, Clinton M. Carman Jun 2016

Eric W. Rood Administration Center- Fire Protection And Life Safety Analysis, Clinton M. Carman

Fire Protection Engineering: Culminating Experience Project Reports

A Fire Protection & Life Safety Analysis was conducted in order to fulfill the requirements for the degree of Master of Science in Fire Protection Engineering. The Fire Protection & Life Safety Analysis consisted of a prescriptive and performance-based analysis of the Eric Rood Administration Center (Rood Center).

The prescriptive based analysis was conducted to determine if the Rood Center adhered to the applicable codes and standards. It utilized the 2013 California Building and Fire Codes and the 2012 Life Safety Code (NFPA 101). Other NFPA codes that were referenced included the 2013 edition of NFPA 13, Standard for the …


Taylor Place- Fire Life Safety Report, Christopher Thomas Mar 2016

Taylor Place- Fire Life Safety Report, Christopher Thomas

Fire Protection Engineering: Culminating Experience Project Reports

This document is a Fire and Life Safety Report on the Taylor Place Dormitory located in Phoenix, Arizona as part of the Arizona State University (ASU) downtown campus. The building was evaluated on a prescriptive basis based on the current City of Phoenix building codes and further evaluated on using performance based methods from the Society of Fire Protection Engineers (SFPE) Handbook and National Fire Protection Association (NFPA) 101 Life Safety Code®.

These building features and systems were evaluated using prescriptive methods:

General construction, fire resistive construction and fire resistive separations Occupancy, Life safety features and building egress Smoke management …