Cal Poly State University Robert E. Kennedy Library Fire Protection Analysis Report, Timothy Anderson Jun 2019

Cal Poly State University Robert E. Kennedy Library Fire Protection Analysis Report, Timothy Anderson

Culminating Experience Project Reports in Fire Protection Engineering

This report determines whether or not the fire protection and life safety features of Robert E. Kennedy Library are consistent with the fire protection objectives established in nationally recognized fire protection codes and standards. This analysis is performed to establish a technical baseline for identification of fire protection deficiencies.

Kennedy Library is the campus student library at California Polytechnic State University. The facility provides resources and services in a variety of media to meet the needs of university students and faculty.

This analysis consists of a prescriptive analysis and a performance-based analysis. The prescriptive analysis is an analysis of the ...


General Purpose Laboratory Building 33- Lawrence Berkeley National Laboratory, Nicholas Tran Jun 2018

General Purpose Laboratory Building 33- Lawrence Berkeley National Laboratory, Nicholas Tran

Culminating Experience Project Reports in Fire Protection Engineering

A detailed study of the fire and life safety systems in the General Purpose Laboratory at the Lawrence Berkeley National Laboratory was performed. The prescriptive and performance-based methods for fire and life safety requirements were analyzed in accordance with the applicable codes. The prescriptive items examined included the egress capacities, fire suppression systems, fire detection and notification systems, and structural construction requirements. The performance-based models utilized studied fire growth and its impact on the fire suppression systems as well as time to egress for the occupants. The General Purpose Laboratory was found to be compliant with the prescriptive requirements in ...


Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen Jun 2018

Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen

Culminating Experience Project Reports in Fire Protection Engineering

Analyzing the fire protection features of the Warren J. Baker Center for Science and Mathematics Building 180, located on Cal Poly Campus in San Luis Obispo California was done using two methods. The prescriptive based analysis of the building focused on the building design, egress, structural fire protection, fire suppression, fire alarm and detection systems to determine if current codes and standards were meet. The performance based analysis discusses certain methods and design fire scenarios that are present within the building and the building’s ability to protect occupants until they can exit safely. The performance based analysis was done ...


Shyh Wang Hall- Lbnl Building 59, Mike Torkelson Jun 2018

Shyh Wang Hall- Lbnl Building 59, Mike Torkelson

Culminating Experience Project Reports in Fire Protection Engineering

This report details the fire and life safety analysis of Shyh Wang Hall, a new building at the Lawrence Berkeley National Laboratory. Wang Hall houses offices, high performance computers, and associated mechanical space. The building is constructed as a Type IIB structure and includes four stories. Both prescriptive-based and performance-based design is considered.

The prescriptive analysis considers the fire and life safety features as required by applicable codes, including the Department of Energy requirements. The building is protected by fire detection and alarm system as well as automatic sprinklers. The prescriptive design meets the code requirements with the possible exception ...


Prescriptive And Performance Analysis Of Cold Machine Shop, John Kline Jun 2018

Prescriptive And Performance Analysis Of Cold Machine Shop, John Kline

Culminating Experience Project Reports in Fire Protection Engineering

The purpose of this report is to analyze the fire and life safety aspects of the Cold Machine Shop located on the central coast of California. This report includes both a prescriptive and performance based analysis.

The prescriptive analysis will evaluate the building as follows, to ensure compliance with standard codes: 1)Egress analysis and design using NFPA 101, "Life Safety Code", 2)Fire detection, alarms, and communication systems using NFPA 72, "National Fire Alarm and Signaling Code", 3)Water-based fire suppression systems using NFPA 13, " Standard for Installation of Sprinkler Systems" and NFPA 14, " Standard for the Installation of ...


Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman Mar 2018

Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman

Culminating Experience Project Reports in Fire Protection Engineering

A Fire and Life Safety Analysis was performed as an academic exercise as part of the MS Fire Protection Engineering Program of California Polytechnic State University, San Luis Obispo. The project is a culminating report with regards to prescriptive based and performance based aspects for the fire and life safety analysis of a project building. These analyses were performed on a building located on a college campus in Southern California and is to remain nameless upon the request of the owner and architect. The building is in the School of Physical Sciences at the University it resides. The building houses ...


Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker Dec 2017

Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker

Culminating Experience Project Reports in Fire Protection Engineering

The purpose of the fire and life-safety analysis was to perform a prescriptive-based and performance based analysis on the fire and life safety systems in the Production Facility (PF) at Sandia National Laboratories (SNL). The prescriptive-based analysis determined if the building met applicable code requirements for existing life safety systems. The performance-based analysis consisted of a series of fire scenarios to ensure the fire and life safety systems allowed adequate egress time for occupants in the event of a fire. The prescriptive-based analysis was based on the Life Safety Code (LSC) and the International Building Code (IBC). The occupancy of ...


Taft Community College- New Student Center- Fire And Life Safety Analysis, Matthew Winston Jun 2017

Taft Community College- New Student Center- Fire And Life Safety Analysis, Matthew Winston

Culminating Experience Project Reports in Fire Protection Engineering

The following report is a fire and life safety investigation into a new facility. The planned facility is a new Student Center at Taft Community College. The prescriptive requirements as set forth by the most up to date codes and standards chosen for the project are met. The building has been properly classified with respect to occupancy and construction type. Appropriate design for interior partitions and exterior walls have been identified. Interior finish requirements are elaborated so that adherence to these guidelines is made clear. The fire sprinkler system has an adequate supply of water from the municipal water supply ...


Dci Data Center Building- Fire Protection Analysis, Bryan Hathaway Jun 2017

Dci Data Center Building- Fire Protection Analysis, Bryan Hathaway

Culminating Experience Project Reports in Fire Protection Engineering

A fire protection analysis utilizing prescriptive and performance based design was performed for the existing building (DCIB) located in Minnesota. A new tenant is investigating converting the DCIB from a building used for data center, to an office building which will utilize an open office concept.

A prescriptive analysis of the building was performed to determine the life safety, fire suppression, fire alarm and structural requirements to ensure compliance with current applicable codes and standards. The prescriptive requirements are outlined and reviewed in Section 1 through Section 5 of this analysis. Modifications to the DCIB are required to achieve the ...


Los Angeles Air Force Base Fitness Center, Colin White Jun 2017

Los Angeles Air Force Base Fitness Center, Colin White

Culminating Experience Project Reports in Fire Protection Engineering

The purpose of this report is to evaluate the life safety features of the Los Angeles Air Force Base Fitness Center, located on Los Angeles Air Force Base in El Segundo, California. This report is produced in partial fulfillment of the requirements of a Master’s of Science in Fire Protection Engineering from the Fire Protection Engineering Program at California Polytechnic State University’s San Luis Obispo Campus. This analysis approaches life safety in the fitness center from two angles. First, a prescriptive approach is used to evaluate the building’s compliance with current codes and standards that govern construction ...


Acme Semiconductor Foundry- Fab Expansion- Fire Protection Engineering Analysis Report, Jacob Epstein Jun 2017

Acme Semiconductor Foundry- Fab Expansion- Fire Protection Engineering Analysis Report, Jacob Epstein

Culminating Experience Project Reports in Fire Protection Engineering

The ACME Semiconductor Foundry – Fab Expansion is a new four story addition to an existing four story foundry facility. The Fab Expansion is approximately 154,500 square feet in footprint area that is connected to an existing four-story Fab Building. This report has been prepared to identify the building’s fire protection and life safety features that must be provided in accordance with the applicable codes and standards. The ACME Semiconductor Fab Expansion will contain multiple separated uses and will be required to be constructed with Type I-B construction. Building Construction Documents are provided in Appendix A showing compliance with ...


Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan Jun 2017

Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan

Culminating Experience Project Reports in Fire Protection Engineering

This report discusses the fire and life safety analysis of the existing fire protection features installed in the Recreation Center building on the California Polytechnic State University. The analysis is conducted using two different approaches, the prescriptive analysis of the building and the performance-based design analysis.

The prescriptive analysis approach will examine installed fire protection features and systems in accordance with the International Building Code, such as structural fire protection, water-based suppression system, alarm and detection system, egress system, smoke control, and fire safety management plan. The egress system failed when the old gym area was used as a fixed ...


Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen Mar 2017

Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen

Culminating Experience Project Reports in Fire Protection Engineering

The Robert E. Kennedy Library is located on Cal Poly Campus. The Library is a five-story building with different occupancies which consists of library areas, offices, mechanical equipment and storage areas. The building has a total area of 178 702 ft². The original code of construction for the Library was the 1976 Uniform Building code (UBC). However, the fire and life safety analysis of the building in this report is performed using: Egress: NFPA 101 LSC 2015, Water based suppression: NFPA 13, Structural fire protection: 2015 IBC, Fire detection, alarm and communication systems: NFPA 72, Performance based design: NFPA 101 ...


Building- Fire Protection Analysis Report, Chris Schwendiman Mar 2017

Building- Fire Protection Analysis Report, Chris Schwendiman

Culminating Experience Project Reports in Fire Protection Engineering

The building in XXX was constructed in XXX. It was designed using the International Building Code (IBC). This fire protection analysis report will be reviewing the building based on the 2015 edition of the IBC including several performance based fire scenarios involving the smoke exhaust system.

The passive system section highlights the physical construction of the building. The building is a business occupancy with three separate stories including a penthouse which is included in the third story. The building has adequate fire ratings for a Type II-B construction except for heavy timber columns within the commons of the building. It ...


Fire And Life Safety Analysis- Warren J. Baker Center For Science And Mathematics, Chad Rudolph Graves Mar 2017

Fire And Life Safety Analysis- Warren J. Baker Center For Science And Mathematics, Chad Rudolph Graves

Culminating Experience Project Reports in Fire Protection Engineering

This report covers the fire protection features of the Warren J. Baker Center for Science and Mathematics located on Cal Poly Campus San Luis Obispo California. The prescriptive analysis of the building will focus on the structural fire protection, egress, fire suppression, fire alarm and detection systems to determine if the meet current codes and standards. The performance based analysis will discuss certain methods and design fire scenarios that can be present within the building and the buildings ability to protect occupants until they can exit safely.

The purpose of this report is to determine if the selected building is ...


Fire And Life Safety Evaluation Of Christopher Cohan Center, Mishuk Datta Mar 2017

Fire And Life Safety Evaluation Of Christopher Cohan Center, Mishuk Datta

Culminating Experience Project Reports in Fire Protection Engineering

A prescriptive and performance-based fire and life safety evaluation for Christopher Cohan Center is performed. The results and findings of the evaluations are conveyed in this report. Christopher Cohan Center was built in accordance with California Building Code (1992 Edition) and California Fire Code (1992 Edition). The current version (2015) of International Building Code is consulted for prescriptive evaluation. The protection requirements set forth in IBC are intended to limit the threat from stage fires to an audience, to reduce the likelihood of a large fire in the stage area and to reduce the possibility of irrational mass response. These ...


Orfalea College Of Business Fire Safety Analysis, Garth Ornelas Mar 2017

Orfalea College Of Business Fire Safety Analysis, Garth Ornelas

Culminating Experience Project Reports in Fire Protection Engineering

The following report discusses the fire and life safety factors for the Orfalea College of Business Building located on the main campus of California Polytechnic State University in San Luis Obispo. The building functions are primarily administrative and academic in nature, with various lecture halls, offices, and labs located throughout the building. The Business Building was constructed in 1989 following the 1985 Uniform Building Code (UBC). For the purposes of this report, the building will be evaluated using the 2015 International Building Code, NFPA Life Safety Code Handbook (Thirteenth Edition), SFPE Handbook (4th and 5th Editions), and the NFPA handbooks ...


Henderson Engineers Building- Fire Protection, Life Safety Code Compliance, And Key Issues Report, Alex Ataiyan Jun 2016

Henderson Engineers Building- Fire Protection, Life Safety Code Compliance, And Key Issues Report, Alex Ataiyan

Culminating Experience Project Reports in Fire Protection Engineering

A fire protection and life safety analysis of the Henderson Engineers, Inc. (HEI) building in Lenexa, KS (Kansas City) is performed. Both prescriptive and performance-based methods have been used to evaluate the building against the codes and standards of the 2012 International Building Code (IBC).

The following prescriptive fire protection and life safety systems were analyzed: Occupancy Classification, Building Construction Type, Fire Protection Features, Structural Fire Protection, Fire Barriers, Automatic Fire Sprinkler System, Fire Alarm System, and Means of Egress

During the prescriptive approach, the following deficiencies were identified: 1) As-builts indicate a horizontal assembly fire-resistance rating of only 1-hour ...


Analysis Of The Seattle Customer Delivery Center, Cynthia Wernet Jun 2016

Analysis Of The Seattle Customer Delivery Center, Cynthia Wernet

Culminating Experience Project Reports in Fire Protection Engineering

The purpose of this analysis is to assess how the Customer Delivery Center (CDC) satisfies prescriptive design requirements of the 2012 International Building Code (IBC) for fire exiting, structural design, smoke detection, alarm notification and communication and water-based fire suppression. A performance-based analysis is then performed using hand calculations and computer-based models to determine if the available safe egress time exceeds the required safe egress time from the building. In order to complete this analysis, the issued-for-construction design and the contractor submittals were made accessible by the owner’s fire protection engineer and the project management group overseeing construction. These ...


Office Building- Fire Protection Systems Evaluation, Christine Newton Jun 2016

Office Building- Fire Protection Systems Evaluation, Christine Newton

Culminating Experience Project Reports in Fire Protection Engineering

This report is a Life Safety Code (LSC) and fire protection systems evaluation of an office building located in Colorado. This report covers the prescriptive analysis of the building, as well as the performance‐based aspect of the evaluation.

The prescriptive analysis of this report includes assessment of the building code for structural design, means of egress, detection and notification systems, smoke control system, and the water‐ based fire suppression system for this building. The 2012 International Building Code (IBC) and the National Fire Protection Agency (NFPA) 101 LSC were used for the prescriptive based evaluation and the building was ...


Sheraton Hotel- Life Safety Report, Raul M. Farfan Jun 2016

Sheraton Hotel- Life Safety Report, Raul M. Farfan

Culminating Experience Project Reports in Fire Protection Engineering

This report evaluates the prescriptive life safety requirements for levels one (1) through four (4) of the Sheraton Hotel in downtown Phoenix. In addition, this report discusses two fire scenarios that evaluate the tenability during egress the in pre-function area on level two (2) and in the main ballroom on level three (3) of the hotel.

The prescriptive standards/codes used to evaluate the hotel are the International Building Code (IBC), International Fire Code (IFC), and applicable standards from the National Fire Protection Association (NFPA). Performance based analysis were conducted using Pathfinder, CFast, and Fire Dynamic Simulator (FDS). Two fire ...


Office High Rise Building- Fire Protection And Life Safety Analysis, Fabio Renato Zocal Mazza Jun 2016

Office High Rise Building- Fire Protection And Life Safety Analysis, Fabio Renato Zocal Mazza

Culminating Experience Project Reports in Fire Protection Engineering

This project developed the traditional prescriptive-based design analysis of the fire protection features of an existing office high rise building in the city of Sao Paulo, in Brazil. The analysis was then complemented by performance-based analysis of the building. The building is a high rise office located in a metropolitan area, provided also with underground car parking garages and a small theater. The fire protection analysis was conducted based on the local Sao Paulo state fire codes, mainly the Sao Paulo State enactment (Decreto Nº56.819/2011) and Sao Paulo Fire Department Technical Instructions; and, in addition to the local ...


Maintenance Shop Building- Comprehensive Fire Protection Evaluation, Theodore P. Stanton Mar 2016

Maintenance Shop Building- Comprehensive Fire Protection Evaluation, Theodore P. Stanton

Culminating Experience Project Reports in Fire Protection Engineering

The purpose of this report is to analyze the fire protection systems and features of the Maintenance Shop Building (MSB), which is a two story office and training building on the campus of a large industrial facility in central California. The goal of the fire protection systems and features of the Building is to provide occupants with reasonable assurance of safety from fire. This goal can be met by ensuring that occupants not intimate with the initiation of a fire will be able to safely escape from the Building in the event of the fire.

The ability of the MSB ...


Taylor Place- Fire Life Safety Report, Christopher Thomas Mar 2016

Taylor Place- Fire Life Safety Report, Christopher Thomas

Culminating Experience Project Reports in Fire Protection Engineering

This document is a Fire and Life Safety Report on the Taylor Place Dormitory located in Phoenix, Arizona as part of the Arizona State University (ASU) downtown campus. The building was evaluated on a prescriptive basis based on the current City of Phoenix building codes and further evaluated on using performance based methods from the Society of Fire Protection Engineers (SFPE) Handbook and National Fire Protection Association (NFPA) 101 Life Safety Code®.

These building features and systems were evaluated using prescriptive methods:

General construction, fire resistive construction and fire resistive separations Occupancy, Life safety features and building egress Smoke management ...


Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows Mar 2016

Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows

Culminating Experience Project Reports in Fire Protection Engineering

A Fire Protection Engineering Analysis was performed on TA‐3‐0040, Physics Building at the Los Alamos National Laboratory in Los Alamos, New Mexico. The goal of the analysis has two parts; first, to examine the buildings fire protection features from a code based prescriptive analysis and second, to examine the building and fire protection features using a performance based design analysis.

Building 40 is a 2 story structure approximately 187,000 square feet. The building was constructed in the mid‐1950s with a first floor, basement, partial sub‐basement, and various mezzanines. Originally, this building was constructed as a ...


Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer Jun 2015

Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer

Culminating Experience Project Reports in Fire Protection Engineering

This fire and life safety report covers a Battalion Headquarters Complex that is used for housing military troops. This is a complete review of the building with prescriptive based fire protection along with performance base review of the building. The prescriptive fire protection covers egress analysis of the space, passive fire protection (i.e. fire walls and doors) and active fire protection (i.e. fire alarm and fire sprinklers). The performance based section looks at the prescriptive requirements and sees if these would be enough for the application at hand. The building fire protection and life safety are covered by ...


Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes Jun 2015

Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes

Culminating Experience Project Reports in Fire Protection Engineering

This is an analysis of a 1970’s vintage building as it is compared to current building codes and standards. The purpose of this document is to assess if the current, as found construction of an existing building could achieve the sometimes more restrictive modern building codes. Both a prescriptive analysis and a performance-based analysis were completed to verify life-safety concerns and criteria as well as construction criteria. The prescriptive analysis compared existing, as found construction to current codes and standards while the prescriptive analysis used modern fire modeling techniques to see how likely fire scenarios would challenge the structure ...


Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller Mar 2015

Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller

Culminating Experience Project Reports in Fire Protection Engineering

The purpose of this report is to analyze Building 310 with regards to fire and life safety. Analysis was done both prescriptively and from a performance based design standpoint. The prescriptive based analysis includes review of the building’s design with regards to egress, fire alarm systems, suppression systems, and structural fire protection. The building was reviewed against current NFPA codes and the International Building Code to examine compliance. The performance-based analysis consists of two different fire scenarios that were examined. The goal was to show that the building met safety criteria and does not pose undue risk to occupants ...


Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott Mar 2015

Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott

Culminating Experience Project Reports in Fire Protection Engineering

This report covers both a prescriptive and performance-based review of fire and life safety systems for the Solar Energy Research Center at the Lawrence Berkeley National Laboratory. The primary subjects covered are egress, fire alarm systems, and sprinkler systems. A unique feature and focal point for this report is the SERC east exit stair. This stair was originally designed as a glass atrium, but for various reasons cannot be utilized as an atrium. The east exit stair has a special VESDA detection system, is the most remote location for the sprinkler system, and is a primary exit for all three ...


Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson Jun 2014

Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson

Culminating Experience Project Reports in Fire Protection Engineering

This document is the report of the culminating experience as part of the master’s program in fire protection engineering at the California Polytechnic State University, San Luis Obispo. This report contains a life safety analysis of the fire protection systems of a chosen project building. The building examined is the Robert and Margrit Mondavi Center for the Performing Arts, located on the University of California Davis campus. The building was constructed in 2002 where the first performance occurred in October 2002. A large portion of the report applies prescriptive code requirements to evaluate compliance with current codes and standards ...