Full-Text Articles in Other Engineering
Sandia National Laboratories' Building 858/North Fabrication Facility, Daniel Garcia
Sandia National Laboratories' Building 858/North Fabrication Facility, Daniel Garcia
Fire Protection Engineering: Culminating Experience Project Reports
In this report, a fire protection and fire hazard analysis has been performed on a semi- conductor facility, abbreviated as the Fab, located on Kirtland Air Force Base in Albuquerque, New Mexico. The Fab is part of the MESA complex which is operated by the NTESS Corporation for the Department of Energy (DOE) at Sandia National Laboratories. The prescriptive analysis of this report addresses the various fire protection systems in the facility such as fire suppression, and fire alarm. The prescriptive analysis is based on national codes and standards from the National Fire Protection Association (NFPA) and from the International …
Los Angeles Air Force Base Fitness Center, Colin White
Los Angeles Air Force Base Fitness Center, Colin White
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this report is to evaluate the life safety features of the Los Angeles Air Force Base Fitness Center, located on Los Angeles Air Force Base in El Segundo, California. This report is produced in partial fulfillment of the requirements of a Master’s of Science in Fire Protection Engineering from the Fire Protection Engineering Program at California Polytechnic State University’s San Luis Obispo Campus. This analysis approaches life safety in the fitness center from two angles. First, a prescriptive approach is used to evaluate the building’s compliance with current codes and standards that govern construction and maintenance of …
Child Development Center- Fire Protection Analysis, Tyler Ball
Child Development Center- Fire Protection Analysis, Tyler Ball
Fire Protection Engineering: Culminating Experience Project Reports
This report contains two separate forms of analysis, Prescriptive-Based Analysis and Performance-Base Analysis. The Prescriptive Analysis discusses an overview of the building and its features whereas the Performance-Based Analysis discusses the building meeting applicable codes and standards as discussed in NFPA 101 Life Safety Code 2012 Edition, Unified Facilities Code (UFC), International Building Code (IBC) 2012 Edition, and the SFPE Handbook of Fire Protection Engineering. The Child Development Center (CDC) was analyzed as a new construction building. There are also noted assumptions within the report where necessary information about the building could not be obtained due to information restrictions from …
Maumus Center- Fire Protection Engineering Analysis, Tyler Mobley
Maumus Center- Fire Protection Engineering Analysis, Tyler Mobley
Fire Protection Engineering: Culminating Experience Project Reports
This report is a fire protection engineering analysis of the Maumus Center, a science center and planetarium, in Arabi, Louisiana. The objective of this analysis is to outline the code defined requirements and to confirm the minimum level of safety from fire is attained. Analyzed in the report are the design requirements prescribed in the adopted building and life safety codes, and the performance of the prescribed design. The prescriptive review addresses the building construction in regards to fire protection, the means of egress, the water‐based fire suppression system, and the fire alarm system. The performance review incorporates the goals …