Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker Dec 2017

Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of the fire and life-safety analysis was to perform a prescriptive-based and performance based analysis on the fire and life safety systems in the Production Facility (PF) at Sandia National Laboratories (SNL). The prescriptive-based analysis determined if the building met applicable code requirements for existing life safety systems. The performance-based analysis consisted of a series of fire scenarios to ensure the fire and life safety systems allowed adequate egress time for occupants in the event of a fire. The prescriptive-based analysis was based on the Life Safety Code (LSC) and the International Building Code (IBC). The occupancy of …


Warren J. Baker Center For Science Building Review, John Pagliero Jun 2017

Warren J. Baker Center For Science Building Review, John Pagliero

Fire Protection Engineering: Culminating Experience Project Reports

This report is a focused review and discussion of the life safety and fire protection design of Cal Poly Building 180: The Warren J. Baker Center for Science in partial fulfillment for the requirements of a Master’s of Science degree in Fire Protection Engineering at Cal Poly, San Luis Obispo. The report focuses on discussion areas specific to the curriculum of the Cal Poly Fire Protection Master’s program, including analysis of egress, structural fire protection, detection, alarm and automatic protection designs in comparison to current and effective codes and standards. This report also includes a, performance based, tenability analysis for …


Orfalea College Of Business- Fire & Life Safety Analysis, Napoleon E. Nino Jun 2017

Orfalea College Of Business- Fire & Life Safety Analysis, Napoleon E. Nino

Fire Protection Engineering: Culminating Experience Project Reports

This report details the prescriptive and performance based analyses performed on the Orfalea College of Business building, located on the Cal Poly San Luis Obispo campus. Designed in accordance with the 1985 Uniform Building Code (UBC), this building is evaluated for compliance with the requirements prescribed under relevant codes in place as of 2016. The main function of this building is to serve both academic and administrative purposes, including classrooms and staff offices. Aspects of the building analyzed include: Egress Systems, Structural Fire Protection, Smoke Management, Fire Detection, Fire Notification, and Fire Suppression The prescriptive analysis demonstrates the lack of …


Acme Semiconductor Foundry- Fab Expansion- Fire Protection Engineering Analysis Report, Jacob Epstein Jun 2017

Acme Semiconductor Foundry- Fab Expansion- Fire Protection Engineering Analysis Report, Jacob Epstein

Fire Protection Engineering: Culminating Experience Project Reports

The ACME Semiconductor Foundry – Fab Expansion is a new four story addition to an existing four story foundry facility. The Fab Expansion is approximately 154,500 square feet in footprint area that is connected to an existing four-story Fab Building. This report has been prepared to identify the building’s fire protection and life safety features that must be provided in accordance with the applicable codes and standards. The ACME Semiconductor Fab Expansion will contain multiple separated uses and will be required to be constructed with Type I-B construction. Building Construction Documents are provided in Appendix A showing compliance with the …


Dci Data Center Building- Fire Protection Analysis, Bryan Hathaway Jun 2017

Dci Data Center Building- Fire Protection Analysis, Bryan Hathaway

Fire Protection Engineering: Culminating Experience Project Reports

A fire protection analysis utilizing prescriptive and performance based design was performed for the existing building (DCIB) located in Minnesota. A new tenant is investigating converting the DCIB from a building used for data center, to an office building which will utilize an open office concept.

A prescriptive analysis of the building was performed to determine the life safety, fire suppression, fire alarm and structural requirements to ensure compliance with current applicable codes and standards. The prescriptive requirements are outlined and reviewed in Section 1 through Section 5 of this analysis. Modifications to the DCIB are required to achieve the …


Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan Jun 2017

Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan

Fire Protection Engineering: Culminating Experience Project Reports

This report discusses the fire and life safety analysis of the existing fire protection features installed in the Recreation Center building on the California Polytechnic State University. The analysis is conducted using two different approaches, the prescriptive analysis of the building and the performance-based design analysis.

The prescriptive analysis approach will examine installed fire protection features and systems in accordance with the International Building Code, such as structural fire protection, water-based suppression system, alarm and detection system, egress system, smoke control, and fire safety management plan. The egress system failed when the old gym area was used as a fixed …


Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen Mar 2017

Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen

Fire Protection Engineering: Culminating Experience Project Reports

The Robert E. Kennedy Library is located on Cal Poly Campus. The Library is a five-story building with different occupancies which consists of library areas, offices, mechanical equipment and storage areas. The building has a total area of 178 702 ft². The original code of construction for the Library was the 1976 Uniform Building code (UBC). However, the fire and life safety analysis of the building in this report is performed using: Egress: NFPA 101 LSC 2015, Water based suppression: NFPA 13, Structural fire protection: 2015 IBC, Fire detection, alarm and communication systems: NFPA 72, Performance based design: NFPA 101 …


Fire And Life Safety Report Orfalea College Of Business, Sulaiman Almohammadi Mar 2017

Fire And Life Safety Report Orfalea College Of Business, Sulaiman Almohammadi

Fire Protection Engineering: Culminating Experience Project Reports

A comprehensive fire and life safety analysis was performed on the Orfalea College of Business. The report covers the prescriptive analysis of the building and the performance-based design analysis. The prescriptive analysis includes assessment of the relevant codes for egress system, water-based suppression system, alarm and detection system, and structural fire protection. The egress analysis under the Life Safety Code 2015 found the building meets the requirements of occupant load to exceed exit capacity, number of exits and its location, travel distances. Four rooms on the second floor that have not met the common path of travel distances limits were …


Fire And Life Safety Analysis- Warren J. Baker Center For Science And Mathematics, Chad Rudolph Graves Mar 2017

Fire And Life Safety Analysis- Warren J. Baker Center For Science And Mathematics, Chad Rudolph Graves

Fire Protection Engineering: Culminating Experience Project Reports

This report covers the fire protection features of the Warren J. Baker Center for Science and Mathematics located on Cal Poly Campus San Luis Obispo California. The prescriptive analysis of the building will focus on the structural fire protection, egress, fire suppression, fire alarm and detection systems to determine if the meet current codes and standards. The performance based analysis will discuss certain methods and design fire scenarios that can be present within the building and the buildings ability to protect occupants until they can exit safely.

The purpose of this report is to determine if the selected building is …


Orfalea College Of Business Fire Safety Analysis, Garth Ornelas Mar 2017

Orfalea College Of Business Fire Safety Analysis, Garth Ornelas

Fire Protection Engineering: Culminating Experience Project Reports

The following report discusses the fire and life safety factors for the Orfalea College of Business Building located on the main campus of California Polytechnic State University in San Luis Obispo. The building functions are primarily administrative and academic in nature, with various lecture halls, offices, and labs located throughout the building. The Business Building was constructed in 1989 following the 1985 Uniform Building Code (UBC). For the purposes of this report, the building will be evaluated using the 2015 International Building Code, NFPA Life Safety Code Handbook (Thirteenth Edition), SFPE Handbook (4th and 5th Editions), and the NFPA handbooks …