Fire Protection And Life Safety Analysis Of A Modern Distributon Facility, Nolan Mccarthy Jun 2015

Fire Protection And Life Safety Analysis Of A Modern Distributon Facility, Nolan Mccarthy

Fire Protection Engineering: Culminating Experience Project Reports

Warehouse facilities are part of the backbone of American industry. The vast amounts of varying goods stored and distributed as part of American business has always driven the need for large, voluminous warehouses. And the increasing size of these facilities over the decades is very closely linked to the capabilities of and advances in fire protection knowledge and technology. Today’s modern distribution centers easily and often exceed one million square feet in area, and the heights are ever increasing. In the 1970’s and early 1980’s, most warehouse facilities were built to an approximate height of 30 feet; this, at the …


Comprehensive Fire Protection And Life Safety Evaluation Of The Robotic Manufacturing Science And Engineering Laboratories (Rmsel) Facility, Tomas M. Sanchez Jun 2015

Comprehensive Fire Protection And Life Safety Evaluation Of The Robotic Manufacturing Science And Engineering Laboratories (Rmsel) Facility, Tomas M. Sanchez

Fire Protection Engineering: Culminating Experience Project Reports

A comprehensive fire protection and life safety evaluation has been performed for the Robotic Manufacturing Science and Engineering Laboratory (RMSEL) at Sandia National Laboratories (SNL). The evaluation considered both prescriptive and performance based aspects. Current codes, such as the 2012 International Building Code and the 2013 version of NFPA 13 – Standard for the Installation of Sprinkler Systems, are generally the basis for the prescriptive evaluation even though they are not the code of record for the building. Use of current codes for this evaluation is mostly for academic reasons. Nevertheless, the facility is generally compliant with the provisions of …


Fire Protection Engineering Analysis For Building 910 - Sandia National Labs/Ca, Mo Mosallaei Jun 2015

Fire Protection Engineering Analysis For Building 910 - Sandia National Labs/Ca, Mo Mosallaei

Fire Protection Engineering: Culminating Experience Project Reports

This Fire Protection Engineering analysis was performed on Building 910 in Sandia National Laboratories in Livermore, CA to examine the building’s fire safety and fire protection criteria which originally adhered to the 1985 Uniform Building Code. The object of this analysis is to determine the degree of compliance with the prescriptive codes in place today as well compliance with performance based analysis. For the prescriptive analysis consisted of evaluating the buildings occupancy classification, type of construction, egress design, fire detection and alarm systems, fire sprinkler system, Halon System, and structural fire protection are evaluated in terms of the life safety …


Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer Jun 2015

Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety report covers a Battalion Headquarters Complex that is used for housing military troops. This is a complete review of the building with prescriptive based fire protection along with performance base review of the building. The prescriptive fire protection covers egress analysis of the space, passive fire protection (i.e. fire walls and doors) and active fire protection (i.e. fire alarm and fire sprinklers). The performance based section looks at the prescriptive requirements and sees if these would be enough for the application at hand. The building fire protection and life safety are covered by three different …


Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes Jun 2015

Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes

Fire Protection Engineering: Culminating Experience Project Reports

This is an analysis of a 1970’s vintage building as it is compared to current building codes and standards. The purpose of this document is to assess if the current, as found construction of an existing building could achieve the sometimes more restrictive modern building codes. Both a prescriptive analysis and a performance-based analysis were completed to verify life-safety concerns and criteria as well as construction criteria. The prescriptive analysis compared existing, as found construction to current codes and standards while the prescriptive analysis used modern fire modeling techniques to see how likely fire scenarios would challenge the structure, if …


Fire Protection And Life Safety Engineering Analysis- Center For Science And Mathematics, Orelvis Gonzalez Cruz Mar 2015

Fire Protection And Life Safety Engineering Analysis- Center For Science And Mathematics, Orelvis Gonzalez Cruz

Fire Protection Engineering: Culminating Experience Project Reports

The Life Safety and Fire Protection systems in Cal Poly’s Center for Science and Mathematics (CSM) were analyzed and evaluated in this project, according to the requirements of the applicable codes and pertinent standards. The evaluation was conducted through a prescriptive-based approach, in conjunction with a performance-based approach. On one hand, the prescriptive-based approach considered the analysis of the Structural Fire Protection and Means of Egress in the building and the existing Fire Detection/Alarm and Fire Suppression Systems. On the other hand, the performance-based approach included an Egress Analysis, which assessed the Required Safe Egress Time (RSET) and the Available …


Laboratory Building- Sandia National Laboratories, Albuquerque, Nm, Joshua Herrera Mar 2015

Laboratory Building- Sandia National Laboratories, Albuquerque, Nm, Joshua Herrera

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of the culminating report was to perform a prescriptive-based and performance-based analysis on the fire and life safety systems in the laboratory building at Sandia National Laboratories (SNL). The prescriptive-based analysis determined if the laboratory building met applicable code requirements for life safety systems. The performance-based analysis conducted a series of fire scenarios to ensure the fire and life safety systems provided adequate egress time for occupants in the event of a fire. The prescriptive-based analysis was based on the Life Safety Code (LSC) and International Building Code (IBC). The laboratory building is a mixed occupancy building. The …


Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott Mar 2015

Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott

Fire Protection Engineering: Culminating Experience Project Reports

This report covers both a prescriptive and performance-based review of fire and life safety systems for the Solar Energy Research Center at the Lawrence Berkeley National Laboratory. The primary subjects covered are egress, fire alarm systems, and sprinkler systems. A unique feature and focal point for this report is the SERC east exit stair. This stair was originally designed as a glass atrium, but for various reasons cannot be utilized as an atrium. The east exit stair has a special VESDA detection system, is the most remote location for the sprinkler system, and is a primary exit for all three …