Open Access. Powered by Scholars. Published by Universities.®

Other Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

California Polytechnic State University, San Luis Obispo

Available Safe Egress Time (ASET)

Articles 1 - 17 of 17

Full-Text Articles in Other Engineering

University Of Washington Bill & Melinda Gates Center For Computer Science & Engineering, Devin Ide Jun 2023

University Of Washington Bill & Melinda Gates Center For Computer Science & Engineering, Devin Ide

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze and evaluate the prescriptive and performance-based criteria used to design the fire protection systems installed in the Gates Center for Computer Science and Engineering at the University of Washington, Seattle Campus. The Gates Center is a five-story building housing business and assembly spaces such as classrooms, workrooms, offices, a lecture hall, event center, and a café. The main architectural feature is a central atrium, which connects the ground, first, second, and third floors of the building.

Aspects of the prescriptive-based fire protection design include egress, automatic sprinkler systems, detection and notification devices, …


Design Fire Robert E. Kennedy Library, California Polytechnic State, San Luis Obispo, Jennifer Ocampo Jun 2023

Design Fire Robert E. Kennedy Library, California Polytechnic State, San Luis Obispo, Jennifer Ocampo

Fire Protection Engineering: Culminating Experience Project Reports

This report evaluates the fire protection system of the Kennedy Building using a prescriptive approach and a performance-based design. The prescriptive approach evaluates code compliance of the structural design, fire suppression system, alarm and detection and smoke control. The performance-based design evaluates egress and life safety protection and three design fires that could potentially compromise the goals and objectives of the design.

The Kennedy Building is on the Campus of Cal Poly, San Luis Obispo and serves as the primary library of the university. This building has five stories of mixed occupancies. It is partially sprinklered, has limited automatic detection …


Fire Life Safety Design Of Technology Office, Jared Ellis Mar 2023

Fire Life Safety Design Of Technology Office, Jared Ellis

Fire Protection Engineering: Culminating Experience Project Reports

The subject building is an approximately 180,000 SF technology office; the location and some details are omitted for privacy of the project and client. It is a 3-story heavy timber frame (Type IIIA) over 1 level of concrete basement stepped into a hillside.

The building is compliant with the prescriptive building code for egress, fire alarm, and fire sprinkler systems. A NFPA 72 compliant fire detection, notification and communication system is provided. The building is fully sprinklered with a system that is hydraulically designed per NFPA 13, 2016 Section 11.2.3 Water Demand Requirements – Hydraulic Calculation Methods. Water supply is …


Fire Protection And Life Safety Analysis Of The Adult Education Facility, William K.W. Bridges Jun 2022

Fire Protection And Life Safety Analysis Of The Adult Education Facility, William K.W. Bridges

Fire Protection Engineering: Culminating Experience Project Reports

The objective of this report is to provide an analysis of an existing building’s prescriptive-based and performance-based design methods. The intention is to provide the building owner with a working assessment of the building’s current life safety situation, as well as providing recommendations to improve the overall life safety and property protection of the selected building. This report is developed following the writing style and structure to meet the requirement for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University. The analysis includes an evaluation of the building owner’s fire and safety program for the …


A Fire Protection Life Safety Analysis Of Multipurpose Building, Dalower Hossain Aug 2021

A Fire Protection Life Safety Analysis Of Multipurpose Building, Dalower Hossain

Fire Protection Engineering: Culminating Experience Project Reports

The following report is a fire and hazard protection analysis of a new building. This new building is a multi-purpose building called MPB locates in Gazipur, Dhaka, Bangladesh. The prescriptive requirements set by the codes and standards used at time of construction of the building have been met. The building has been properly classified with respect to occupancy as S1, Group B and F-1 and construction Type I A Sprinklered. Appropriate designs for interior partitions and exterior wall have been identified. Interior finish requirements have been analyzed for a better understanding of aesthetics guidelines. Based on the sprinkler drawing calculations, …


Fire Protection And Life Safety Analysis Of Art ‘N Motion, Jordan Albrecht Jun 2021

Fire Protection And Life Safety Analysis Of Art ‘N Motion, Jordan Albrecht

Fire Protection Engineering: Culminating Experience Project Reports

This report includes a fire protection and life safety analysis for the Art ‘n Motion building. This analysis was done to fulfill the requirement for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University. The Art ‘n Motion building is two (2) stories, approximately 17,720 sqft, and is Type III-B construction. The building’s primary use is a vehicle showroom business where multiple exotic and antique vehicles are on display, and can be bought and sold. The building is also used as a home base for a NASCAR team, that operates out of the garage area …


Fire Protection Analysis: Engineering Iv, Building 192, Cal Poly State University, San Luis Obispo, Paul Jenkins Jun 2020

Fire Protection Analysis: Engineering Iv, Building 192, Cal Poly State University, San Luis Obispo, Paul Jenkins

Fire Protection Engineering: Culminating Experience Project Reports

This report is an analysis of the fire protection capabilities of Engineering IV (Building 192) at Cal Poly University in San Luis Obispo, CA. The overall objective of this report was to assess whether the building and its fire protection systems supported the evacuation of occupants from the building in a safe manner before conditions became untenable during a fire event. The assessment was accomplished by performing a prescriptive and performance analysis.

The purpose of the prescriptive analysis was to determine whether the building egress components and fire protections systems were designed, built, and installed in compliance with all the …


Military Maintenance Hangar, Eliot Jordan Jun 2020

Military Maintenance Hangar, Eliot Jordan

Fire Protection Engineering: Culminating Experience Project Reports

This report describes the building code compliance of a military aircraft hangar. The facility is evaluated for both prescriptive code compliance and for a performance-based compliance via the use of design fires analyzed with computer programs Fire Dynamics Simulator (FDS) and occupant egress analyzed with Pathfinder software as well as hand calculations utilizing Excel.

The prescriptive code analysis is done based upon a combination of Unified Facilities Criteria, International Building Code, and NFPA 101 codes and standards. Prescriptive compliance was checked against the building non separated occupancies of S-1 and B. The building was evaluated for building construction type IIB. …


Research Laboratory: Fire, Explosion, And Life Safety Analysis, Dennis A. Tuma Jun 2020

Research Laboratory: Fire, Explosion, And Life Safety Analysis, Dennis A. Tuma

Fire Protection Engineering: Culminating Experience Project Reports

This culminating report is a fire, explosion, and life safety evaluation of a Research Laboratory ("Laboratory") where significant quantities of flammable, combustible, and hazardous materials are used and stored. The report's initial portion provides a prescriptive-based analysis using applicable sections of the 2016 California Building Standard Codes and National Fire Protection Association (NFPA) standards. Because of the unique challenges to hazardous laboratory spaces, the prescriptive- based analysis includes both a review of codes applicable to all occupancies (e.g., egress, fire-resistance, building area), and codes applicable to Group H and L occupancies (e.g., electrical area classification maps, control areas). Unfortunately, detailed …


A Fire Protection Life Safety Analysis Of Permian Oil Plaza, Nick Francis Mar 2019

A Fire Protection Life Safety Analysis Of Permian Oil Plaza, Nick Francis

Fire Protection Engineering: Culminating Experience Project Reports

The Permian Oil Plaza (POP) is a four story building located in Midland, TX. This facility was designed to provide over 200,000 square feet of office space to approximately 500 employees. The building was constructed of unprotected non-combustible (Type II-B) building materials and was completed in late 2015. An assessment of the building’s fire and life safety systems was performed to ensure these systems were designed and installed in a manner that meets, or exceeds, the intent of pertinent building codes and fire safety standards. This assessment included a prescriptive based analysis, as well as a performance-based analysis. The prescriptive …


Construction Innovation Center- Fire And Life Safety Analysis, Matthew Atwell Mar 2018

Construction Innovation Center- Fire And Life Safety Analysis, Matthew Atwell

Fire Protection Engineering: Culminating Experience Project Reports

In this report you will find the analysis of existing fire protection systems and features that are installed in the Construction Innovation Center at California Polytechnic State University, San Luis Obispo. The Buildings construction was completed in 2008 and is separated into three separate buildings A, B, and C connected by an exterior balcony. This report is separated into two separate analysis Prescriptive and Performance.

The Prescriptive analysis reviews the buildings means of egress, fire alarm systems, the suppression systems, and the structural fire protection. The Prescriptive-based analysis of the Construction Innovation Center confirms that the building meets the requirements …


Building- Fire Protection Analysis Report, Chris Schwendiman Mar 2017

Building- Fire Protection Analysis Report, Chris Schwendiman

Fire Protection Engineering: Culminating Experience Project Reports

The building in XXX was constructed in XXX. It was designed using the International Building Code (IBC). This fire protection analysis report will be reviewing the building based on the 2015 edition of the IBC including several performance based fire scenarios involving the smoke exhaust system.

The passive system section highlights the physical construction of the building. The building is a business occupancy with three separate stories including a penthouse which is included in the third story. The building has adequate fire ratings for a Type II-B construction except for heavy timber columns within the commons of the building. It …


Wistron Greentech, Mckinney, Tx- Life Safety Evaluation, Charles R. Cates Mar 2017

Wistron Greentech, Mckinney, Tx- Life Safety Evaluation, Charles R. Cates

Fire Protection Engineering: Culminating Experience Project Reports

A fire protection and life safety review of the Wistron GreenTech facility in McKinney, TX is performed. The facility was reviewed from both a prescriptive (building code) and performance based design per the codes summarized in the report. The prescriptive fire and life safety systems analyzed where the following: Building Code Analysis Including but not limited to: Occupancy classifications, Occupancy separations, Building height and areas, Type of construction, Fire resistive construction, Means of egress, Fire Alarm and Detection Systems, Automatic Fire Sprinklers & Water Supply, Special Hazards, Emergency Planning and Preparedness The prescriptive requirements in general where met, the exceptions …


Building X- Fire Protection System And Life Safety Evaluation, Anthony W. Sublett Jun 2016

Building X- Fire Protection System And Life Safety Evaluation, Anthony W. Sublett

Fire Protection Engineering: Culminating Experience Project Reports

The fire protection and life safety systems for Building X were evaluated for compliance in accordance with applicable nuclear power plant non-power block regulatory requirements, NEIL, INPO, IBC, and NFPA design requirements, codes, and standards. Building X is a one-story building with two internal balconies with 10 occupants per balcony, which is made of non-combustible materials that also has a partial basement with concrete walls (is normally unoccupied), which houses potable water pumps and piping for the facility. Building X falls under the definition of mixed occupancy per the International Building Code (IBC) and the Life Safety Code (LSC). Since …


Fire Protection And Life Safety Analysis- Dell Medical School Academic Building, David Gramlich Jun 2014

Fire Protection And Life Safety Analysis- Dell Medical School Academic Building, David Gramlich

Fire Protection Engineering: Culminating Experience Project Reports

This report is on the Dell Medical School Academic Building located in Austin, Texas. The life safety and prescriptive based code requirements are summarized within this report. It also includes conceptual fire protection and fire alarm system design. This report mentions University of Texas System Owner’s Design Guidelines that exceed the required code requirements. This report was developed when the building was in the Design Development stage. Since, code deficiencies have been addressed, and changes have been made to the building during the remainder of the design process, this report does not reflect the actual construction or protection strategies used …


Orangeburg Assembly Hall Of Jehovah's Witnesses- Fire Protection And Life Safety Design Analysis, Justin B. Biller Mar 2014

Orangeburg Assembly Hall Of Jehovah's Witnesses- Fire Protection And Life Safety Design Analysis, Justin B. Biller

Fire Protection Engineering: Culminating Experience Project Reports

In partial fulfillment of the requirements for the Degree of Masters of Science in Fire Protection Engineering, a prescriptive and performance-based engineering analysis was performed on the Orangeburg Assembly Hall of Jehovah’s Witnesses. The building was recently constructed and completed in 2013 in Orangeburg, South Carolina to serve as a center for education of Jehovah’s Witnesses on Biblical principles for daily life. More than 300 congregations throughout Georgia and the Carolinas will use the Assembly Hall for their semi-annual assemblies and conventions, with an estimated annual attendance of 190,000 per year. Prescriptive analyses were conducted based primarily upon the provisions …


Fire Protection Life Safety Analysis- Bachelor Enlisted Quarters, Kyle C. Leadon Mar 2014

Fire Protection Life Safety Analysis- Bachelor Enlisted Quarters, Kyle C. Leadon

Fire Protection Engineering: Culminating Experience Project Reports

This Bachelor Enlisted Quarters (BEQ) shall be constructed, arranged, equipped, maintained, and operated in accordance with this report and applicable criteria to ensure a minimum level of life safety and property protection is provided from actual and potential fire hazards. The goal is to ensure the occupants are provided with an environment that is reasonably safe from fire. We accomplish this goal by protecting occupants not intimate with the initial fire development, and by improving the survivability of occupants intimate with the initial fire development. The protection described in this report takes on many forms, from active protection, such as …