Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 1 of 1
Full-Text Articles in Nuclear Engineering
Thermal Transient Flow Rate Sensor For High Temperature Liquid Metal Cooled Nuclear Reactor, Yingtao Jiang, Jian Ma, Rohit Reddy Saddi
Thermal Transient Flow Rate Sensor For High Temperature Liquid Metal Cooled Nuclear Reactor, Yingtao Jiang, Jian Ma, Rohit Reddy Saddi
Mechanical Engineering Faculty Research
In nuclear power plants and accelerator driven system (ADS) for nuclear waste treatment, it is important to monitor the coolant flow rate in the reactor core and pipe-line. In such a strong irradiation, high pressure and temperature environment, no accurate local flow measurement technique is readily available. Electromagnetic (EM) flow meter is popular in low temperature application as it is a non-intrusive technology. However, additional voltage will be produced due to temperature, flow, pressure, the chemical properties of the liquid metal and surface condition of the steel walls. In addition, the non-definite wetting behavior of liquid lead-bismuth to the electrically …