Open Access. Powered by Scholars. Published by Universities.®

Applied Mechanics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Applied Mechanics

Crack Growth Behavior Under Creep-Fatigue Conditions Using Compact And Double Edge Notch Tension-Compression Specimens, Santosh B. Narasimha Chary Dec 2013

Crack Growth Behavior Under Creep-Fatigue Conditions Using Compact And Double Edge Notch Tension-Compression Specimens, Santosh B. Narasimha Chary

Graduate Theses and Dissertations

The American Society for Testing and Materials (ASTM) has recently developed a new standard for creep-fatigue crack growth testing, E 2760-10, that supports testing compact specimens, C(T), under load controlled conditions. C(T) specimens are commonly used for fatigue and creep-fatigue crack growth testing under constant-load-amplitude conditions. The use of these specimens is limited to positive load ratios. They are also limited in the amount of crack growth data that can be developed at high stress intensity values due to accumulation of plastic and/or creep strains leading to ratcheting in the specimen. Testing under displacement control can potentially address these shortcomings …


Measurement And Description Of Dynamics Required For In Vivo Surgical Robotics Via Kinematic Methods, Jacob G. Greenburg Aug 2013

Measurement And Description Of Dynamics Required For In Vivo Surgical Robotics Via Kinematic Methods, Jacob G. Greenburg

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

With the goal of improved recovery times and reduced trauma to the patient there has been a substantial shift in the medical community’s demand for minimally invasive surgical (MIS) techniques. With the standardization of MIS becoming more commonplace in the medical field there are still many improvements that are desired. Traditional, manual methods of these surgeries require multiple incisions on the abdomen for the tools and instruments to be inserted. The more recent demand has been to localize the incisions into what is being referred to as a Laparoendoscopic Single-Site (LESS) surgery. Furthermore, the manual instruments that are commonly used …


Loaded Shift Tester Sram, Nick Cox, Sam Shaffer, Michael Polka Jun 2013

Loaded Shift Tester Sram, Nick Cox, Sam Shaffer, Michael Polka

Mechanical Engineering

This report details the design, manufacturing, and testing of a loaded shift tester for the SRAM Bicycle Corporation. The machine is used to perform developmental and qualification tests on various bicycle drivetrain components. Using SolidWorks, the design team created a solid model of the machine on the computer, then ordered and manufactured the parts required to build it. The machine was tested to ensure that all the parts worked together, and was finally delivered to SRAM when it was deemed ready.


Bicycle Wheel Test Machine, Dylan Harper, Kevin Hom, Ross Williams Jun 2013

Bicycle Wheel Test Machine, Dylan Harper, Kevin Hom, Ross Williams

Mechanical Engineering

In recent years, the cycling industry has witnessed huge advancements in bicycle components and materials. The age old goals of speed and low weight are still present today, but the pursuit of these goals may be reducing the structural stability of various components integral to wheel performance, including the wheel hub bearings. These bearings are invaluable to bicycles but little is known about how the forces and loads applied to a bicycle affect the performance of these bearings. Broken axles and hubs are indicators of significant stresses within the hub, but little is known about how the resulting deformation affects …


Rebounder Fatigue Test Machine, Caroline Reeves, Will Robertson, Ethan Flory Jun 2013

Rebounder Fatigue Test Machine, Caroline Reeves, Will Robertson, Ethan Flory

Mechanical Engineering

JumpSport, a company that designs and sells trampolines and trampoline accessories, has sponsored this senior project team to design, build, and test a trampoline fatigue test machine. The machine must simulate a person jumping on the trampoline to test the life of JumpSport’s fitness trampolines and kids’ trampolines. Partway through the design process, the objectives were altered and this senior project team was tasked with merging with another Cal Poly senior project group to create an all-inclusive test machine to accommodate both full-trampoline testing and individual bungee cord testing.

The final design is centered on a slider crank linkage driven …


Design, Fabrication, And Testing Of An Emr Based Orbital Debris Impact Testing Platform, Jeffrey J. Maniglia Jr. Jun 2013

Design, Fabrication, And Testing Of An Emr Based Orbital Debris Impact Testing Platform, Jeffrey J. Maniglia Jr.

Master's Theses

This paper describes the changes made from Cal Poly’s initial railgun system, the Mk. 1 railgun, to the Mk. 1.1 system, as well as the design, fabrication, and testing of a newer and larger Mk. 2 railgun system. The Mk. 1.1 system is developed as a more efficient alteration of the original Mk. 1 system, but is found to be defective due to hardware deficiencies and failure, as well as unforeseen efficiency losses. A Mk. 2 system is developed and built around donated hardware from the Naval Postgraduate School. The Mk. 2 system strove to implement an efficient, augmented, electromagnetic …


The Effect Of Isostatic Pressing On The Dielectric Properties Of Screen Printed Ba0.5Sr0.5Tio3 Thick Films, Siwei Wang, Lingling Zhang, Jiwei Zhai, Fanglin Chen Jan 2013

The Effect Of Isostatic Pressing On The Dielectric Properties Of Screen Printed Ba0.5Sr0.5Tio3 Thick Films, Siwei Wang, Lingling Zhang, Jiwei Zhai, Fanglin Chen

Faculty Publications

Ba0.5Sr0.5TiO3 thick films with B2O3–Li2O glass sintering aid were prepared by the screen printing method on Al2O3 substrates. A 200 MPa isostatic pressure was applied to the films before sintering. After being sintered at 950C, lower porosity and denser microstructure was obtained compared with the films without isostatic pressing. The dielectric constant and dielectric loss were 238 and 0.0028, respectively. A tunability of 61.7% was obtained for the isostatic pressed films, a 27.8% enhancement compared to unpressurized films. These results suggest that isostatic pressing …