Full-Text Articles in Mechanical Engineering

Inverted Fluorescence Microscope, Makenzie Lyn Kamei, Enoch Wright Nicholson, Eduardo Reyna Miranda Jr., Trevor John Brown Jun 2020

Inverted Fluorescence Microscope, Makenzie Lyn Kamei, Enoch Wright Nicholson, Eduardo Reyna Miranda Jr., Trevor John Brown

Mechanical Engineering

The Inverted Fluorescence Microscope senior project team at Cal Poly, San Luis Obispo designed, assembled, and tested a proof-of-concept inverted fluorescence microscope for the university’s Microfabrication Laboratory. Administrators of the laboratory wished to use fluorescence for research and experiments involving cell growth and flow visualization on the micro-scale, and did not have the budget to purchase one of the costly commercially available options. The scope of this design challenge was to produce a low-cost inverted fluorescence microscope employing available optical components and additional readily sourced parts to expand the use of fluorescence microscopy accessible to undergraduate students in the Microfabrication …


The Design And Fabrication Of A Microfluidic Reactor For Synthesis Of Cadmium Selenide Quantum Dots Using Silicon And Glass Substrates, Peter Robert Gonsalves Feb 2012

The Design And Fabrication Of A Microfluidic Reactor For Synthesis Of Cadmium Selenide Quantum Dots Using Silicon And Glass Substrates, Peter Robert Gonsalves

Master's Theses

A microfluidic reactor for synthesizing cadmium selenide (CdSe) quantum dots (QDs) was synthesized out of a silicon wafer and Pyrex glass. Microfabrication techniques were used to etch channels into the silicon wafer. Holes were wet-drilled into the Pyrex glass using a diamond-tip drill bit. The Pyrex wafer was anodically bonded to the etched silicon wafer to enclose the microfluidic reactor. Conditions for anodic bonding were created by exposing the stacked substrates to 300V at ~350oC under 5.46N of force. A syringe containing a room temperature CdSe solution was interfaced to the microfluidic reactor by using Poly (dimethylsiloxane) (PDMS) as an …


Development Of A Low Cost Handheld Microfluidic Phosphate Colorimeter For Water Quality Analysis, Sean C. Kaylor Aug 2009

Development Of A Low Cost Handheld Microfluidic Phosphate Colorimeter For Water Quality Analysis, Sean C. Kaylor

Master's Theses

This thesis describes the design, fabrication, and testing process for a microfluidic phosphate colorimeter utilized for water quality analysis. The device can be powered by, and interfaced for data collection with, a common cell phone or laptop to dramatically reduce costs. Unlike commercially available colorimeters, this device does not require the user to measure or mix sample and reagent. A disposable poly(dimethylsiloxane) (PDMS) microfluid chip, powered by an absorption pumping mechanism, was used to draw water samples, mix the sample at a specific ratio with a molybdovanadate reagent, and load both fluids into an onboard cuvette for colorimetric analysis. A …