Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 18 of 18

Full-Text Articles in Mechanical Engineering

Shape Memory Alloy Capsule Micropump For Drug Delivery Applications, Youssef Mohamed Kotb Jun 2024

Shape Memory Alloy Capsule Micropump For Drug Delivery Applications, Youssef Mohamed Kotb

Theses and Dissertations

Implantable drug delivery devices have many benefits over traditional drug administration techniques and have attracted a lot of attention in recent years. By delivering the medication directly to the tissue, they enable the use of larger localized concentrations, enhancing the efficacy of the treatment. Passive-release drug delivery systems, one of the various ways to provide medication, are great inventions. However, they cannot dispense the medication on demand since they are nonprogrammable. Therefore, active actuators are more advantageous in delivery applications. Smart material actuators, however, have greatly increased in popularity for manufacturing wearable and implantable micropumps due to their high energy …


Borophene And Graphene For Non-Enzymatic Biosensor- Ab-Initio Study, Omar A. Ismail Dec 2023

Borophene And Graphene For Non-Enzymatic Biosensor- Ab-Initio Study, Omar A. Ismail

Theses and Dissertations

Non-enzymatic glucose sensing holds promise to overcome limitations associated with glucose oxidase, such as oxygen dependence and short shelf life. This study explores the potential sensing capabilities of borophene and graphene through direct interaction with various compounds, including β-glucose, uric acid, ascorbic acid, fructose, and acetaminophen. Using Density Functional Theory (DFT), we calculated binding energies and the respective Density of States (DOS) for these adsorbates on both graphene and borophene surfaces. Preliminary results suggest that borophene might exhibit nearly twice the affinity for β-glucose compared to graphene. Moreover, the calculated Density of States reveals distinct distortions in the electronic states …


Algorithms For Rapid Trip Detection In Human Walking Using Inertial Sensors, Chadi Ellouzi Jan 2022

Algorithms For Rapid Trip Detection In Human Walking Using Inertial Sensors, Chadi Ellouzi

Theses and Dissertations

Trips and falls are one of the most common causes for injuries among elderly. The existing trip-and-falls studies primarily focus on the proactive fall prevention approaches, while active prevention strategies remain largely unexplored. This thesis aims to provide first steps towards active trip-and-fall prevention by developing various algorithms capable of detecting trip in human walking faster than the human voluntary reactions (~200 ms). The measurements of human kinematics are used as the inputs in the algorithms. The proposed algorithms include three threshold-based detection methods, an optimized elastic time-series alignment tool called dynamic time warping (DTW) that overcomes problems of time …


Modeling Of Patient-Specific Periaortic Mechanics And Pulmonary Artery Hemodynamics Based On Phase-Contrast Magnetic Resonance Imaging Sequences., Johane H. Bracamonte Jan 2022

Modeling Of Patient-Specific Periaortic Mechanics And Pulmonary Artery Hemodynamics Based On Phase-Contrast Magnetic Resonance Imaging Sequences., Johane H. Bracamonte

Theses and Dissertations

Inverse modeling in cardiovascular medicine is a collection of methodologies that can provide non-invasive patient-specific estimations of clinical risk factors using medical imaging as inputs. Its incorporation into clinical practice has the potential to improve diagnosis and treatment planning with low associated risks and costs.

Herein, three different phase contrast magnetic resonance imaging (MRI) modalities were implemented as input data, displacement encoding with stimulated echoes (DENSE MRI) applied, and time-resolved velocity encoding phase-contrast MRI, in 1D and 3D, applied to pulmonary artery (PA) hemodynamics.

A model to account for the effect of periaortic interactions due to static and dynamic structures …


Nebulizer-Based Systems To Improve Pharmaceutical Aerosol Delivery To The Lungs, Benjamin M. Spence Jan 2021

Nebulizer-Based Systems To Improve Pharmaceutical Aerosol Delivery To The Lungs, Benjamin M. Spence

Theses and Dissertations

Combining vibrating mesh nebulizers with additional new technologies leads to substantial improvements in pharmaceutical aerosol delivery to the lungs across therapeutic administration methods. In this dissertation, streamlined components, aerosol administration synchronization, and/or Excipient Enhanced Growth (EEG) technologies were utilized to develop and test several novel devices and aerosol delivery systems. The first focus of this work was to improve the poor delivery efficiency, e.g., 3.6% of nominal dose (Dugernier et al. 2017), of aerosolized medication administration to adult human subjects concurrent with high flow nasal cannula (HFNC) therapy, a form of continuous-flow non-invasive ventilation (NIV). The developed Low-Volume Mixer-Heater (LVMH) …


Development Of A Single Use Device Intended To Wash Blood Clot Debris From A Stent Retriever In The Operating Room, Shane Diller Jan 2020

Development Of A Single Use Device Intended To Wash Blood Clot Debris From A Stent Retriever In The Operating Room, Shane Diller

Theses and Dissertations

Ischemic stroke is a life-threatening condition that requires immediate surgical intervention to remove the blood clot that is lodged in the blood vessels of the brain. Mechanical thrombectomy, performed by an endovascular surgeon, involves inserting a stent retriever, which deploys distally and attempts to capture the clot when dragged backwards. A complication prevalent in 50% - 67% of cases is that the blood clot is only partially removed and clings to the mesh framework of the stent. The operating surgeon must either clean the debris from the stent retriever, to be reinserted or throw the stent retriever away and open …


Quantification And Modeling Of Bladder Biomechanics Mechanisms Linking Spontaneous Rhythmic Contractions And Dynamic Elasticity To Detrusor Overactivity, Zachary E. Cullingsworth Jan 2020

Quantification And Modeling Of Bladder Biomechanics Mechanisms Linking Spontaneous Rhythmic Contractions And Dynamic Elasticity To Detrusor Overactivity, Zachary E. Cullingsworth

Theses and Dissertations

Overactive bladder (OAB) is a chronic condition affecting approximately 20% of adults in the United States. Detrusor overactivity (DO) is the presence of non-voiding contractions in the detrusor (bladder) muscle during filling and is present in some individuals with OAB. DO is currently identified visually during a urodynamics (UD) study involving pressure catheters and filling and voiding of the bladder to evaluate function. UD provides limited subtyping of DO, and an incomplete understanding of mechanisms contributing to OAB.

Aim 1 of this study was to develop objective tools to quantify, subgroup and better understand …


Development Of An Anatomically And Electrically Conductive Brain Phantom For Transcranial Magnetic Stimulation, Hamzah A. Magsood Jan 2020

Development Of An Anatomically And Electrically Conductive Brain Phantom For Transcranial Magnetic Stimulation, Hamzah A. Magsood

Theses and Dissertations

Transcranial Magnetic Stimulation (TMS) is a non-invasive technique for diagnostics, prognostic, and treatments of various neurological diseases. However, the lack of anatomically realistic brain phantoms has made the experimental verification of stimulation strength in the form of induced electric fields/voltages in the brain tissues an impediment to developing new TMS coils, stimulators, and treatment protocols. There are significant technological, safety, and ethical limitations to test the potential TMS treatment procedures or develop enhancements and refine them on humans or animals. This work aims to bridge the gap by introducing and developing an innovative manufacturing and fabrications process to produce a …


A Computational Study Of The Kinematics Of Femoroacetabular Morphology During A Sit-To-Stand Transfer, Brandon K. Marine Jan 2017

A Computational Study Of The Kinematics Of Femoroacetabular Morphology During A Sit-To-Stand Transfer, Brandon K. Marine

Theses and Dissertations

Computational modeling in the field of biomechanics is becoming increasingly popular and successful in practice for its ability to predict function and provide information that would otherwise be unobtainable. Through the application of these new and constantly improving methods, kinematics and joint contact characteristics in pathological conditions of femoroacetabular impingement (FAI) and total hip arthroplasty (THA) were studied using a lower extremity computational model. Patients presenting with FAI exhibit abnormal contact between the femoral neck and acetabular rim leading to surrounding tissue damage in daily use. THA is the replacement of both the proximal femur and acetabular region of the …


Nanocomposite Bioelectronics For Biopotential Enabled Prosthesis, Dong Sup Lee Jan 2017

Nanocomposite Bioelectronics For Biopotential Enabled Prosthesis, Dong Sup Lee

Theses and Dissertations

Soft material-enabled electronics can demonstrate extreme mechanical flexibility and stretchability. Such compliant, comfortable electronics allow continuous, long-term measurement of biopotentials on the skin. Manufacturing of the stretchable electronic devices is enabled by the recent development combining materials transfer printing and microfabrication. However, the existing method using inorganic materials and multi-layered polymers requires long material preparation time and expensive processing cost due to the requirement of microfabrication tools and complicated transfer printing steps. Here, this study develops a new fabrication method of soft electronics via a micro-replica-molding technique, which allows fast production, multiple use, and low cost by avoiding microfabrication and …


Assessment Of Force Coordination And Neuromuscular Quickness In Healthy Adults, Karen L. Haberland Jan 2016

Assessment Of Force Coordination And Neuromuscular Quickness In Healthy Adults, Karen L. Haberland

Theses and Dissertations

Throughout daily life, it is necessary to handle and control innumerable objects. To do so, one’s hands must be precisely regulated. To ensure that an object is effectively manipulated, an individual must apply a grip force (GF) perpendicular to the object’s surface to overcome load force (LF), which acts tangential to the surface to counteract the object’s weight and inertia. Previous studies have shown an elaborate coordination between GF and LF in a variety of object manipulation tasks in healthy populations. This kinetic analysis is clinically important because the GF-LF coordination is shown to deteriorate in aging and neurologically impaired …


In-Shoe Plantar Pressure System To Investigate Ground Reaction Force Using Android Platform, Ahmed A. Mostfa Jan 2016

In-Shoe Plantar Pressure System To Investigate Ground Reaction Force Using Android Platform, Ahmed A. Mostfa

Theses and Dissertations

Human footwear is not yet designed to optimally relieve pressure on the heel of the foot. Proper foot pressure assessment requires personal training and measurements by specialized machinery. This research aims to investigate and hypothesize about Preferred Transition Speed (PTS) and to classify the gait phase of explicit variances in walking patterns between different subjects. An in-shoe wearable pressure system using Android application was developed to investigate walking patterns and collect data on Activities of Daily Living (ADL). In-shoe circuitry used Flexi-Force A201 sensors placed at three major areas: heel contact, 1st metatarsal, and 5th metatarsal with a PIC16F688 microcontroller …


Efficiency Evaluation Of A Magnetically Driven Multiple Disk Centrifugal Blood Pump, Kayla H. Moody Jan 2016

Efficiency Evaluation Of A Magnetically Driven Multiple Disk Centrifugal Blood Pump, Kayla H. Moody

Theses and Dissertations

Heart failure is expected to ail over 8 million people in America by 2030 leaving many in need of cardiac replacement. To accommodate this large volume of people, ventricular assist devices (VADs) are necessary to provide mechanical circulatory support. Current VADs exhibit issues such as thrombosis and hemolysis caused by large local pressure drops and turbulent flow within the pump. Multiple disk centrifugal pumps (MDCPs) use shearing and centrifugal forces to produce laminar flow patterns and eliminate large pressure drops within the pump which greatly reduce risks that are in current VADs. The MDCP has a shaft drive system (SDS) …


Computational Modeling To Assess Surgical Procedures For The Treatment Of Adult Acquired Flatfoot Deformity, Brian A. Smith Jan 2015

Computational Modeling To Assess Surgical Procedures For The Treatment Of Adult Acquired Flatfoot Deformity, Brian A. Smith

Theses and Dissertations

Several surgically corrective procedures are considered to treat Adult Acquired Flatfoot Deformity (AAFD) patients, relieve pain, and restore function. Procedure selection is based on best practices and surgeon preference. Recent research created patient specific models of Adult Acquired Flatfoot Deformity (AAFD) to explore their predictive capabilities and examine effectiveness of the surgical procedure used to treat the deformity. The models’ behavior was governed solely by patient bodyweight, soft tissue constraints, and joint contact without the assumption of idealized joints. The current work expanded those models to determine if an alternate procedure would be more effective for the individual. These procedures …


A Method To Develop Neck Injury Criteria To Aid Design And Test Of Escape Systems Incorporating Helmet Mounted Displays, Jeffrey C. Parr Sep 2014

A Method To Develop Neck Injury Criteria To Aid Design And Test Of Escape Systems Incorporating Helmet Mounted Displays, Jeffrey C. Parr

Theses and Dissertations

HMDs are becoming common human-machine interface equipment in manned military flight, but introducing this equipment into the overall aircraft escape system poses new and significant system design, development, and test concerns. Although HMDs add capabilities, which improve operator performance, the increased capability is often accompanied by increased head supported mass. The increased mass can amplify the risk of pilot neck injury during ejection when compared to lighter legacy helmets. Currently no adequate USAF neck injury criteria exist to effectively guide the requirements, design, and test of escape systems for pilots with HMDs. This research effort presents a novel method to …


Cfd Assessment Of Respiratory Drug Delivery Efficiency In Adults And Improvements Using Controlled Condensational Growth, Ross L. Walenga Jan 2014

Cfd Assessment Of Respiratory Drug Delivery Efficiency In Adults And Improvements Using Controlled Condensational Growth, Ross L. Walenga

Theses and Dissertations

Pharmaceutical aerosols provide a number of advantages for treating respiratory diseases that include targeting high doses directly to the lungs and reducing exposure of other organs to the medication, which improve effectiveness and minimize side effects. However, difficulties associated with aerosolized drug delivery to the lungs include drug losses in delivery devices and in the extrathoracic region of human upper airways. Intersubject variability of extrathoracic and thoracic drug deposition is a key issue as well and should be minimized. Improvements to respiratory drug delivery efficiency have been recently proposed by Dr. P. Worth Longest and Dr. Michael Hindle through the …


Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza Jan 2014

Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza

Theses and Dissertations

Muscle mechanical behavior potentially plays an important role in some of the most common bladder disorders. These include overactive bladder, which can involve involuntary contractions during bladder filling, and impaired contractility or underactive bladder, which may involve weak or incomplete contractions during voiding. Actin-myosin cross-bridges in detrusor smooth muscle (DSM) are responsible for contracting and emptying the bladder. The total tension produced by muscle is the sum of its preload and active tensions. Studies suggest that actin-myosin cross-links are involved in adjustable preload stiffness (APS), which is characterized by a preload tension curve that can be shifted along the length …


Modeling Acute Changes In Bladder Wall Tension, Shape And Compliance During Filling, Firdaweke Habteyes Jan 2014

Modeling Acute Changes In Bladder Wall Tension, Shape And Compliance During Filling, Firdaweke Habteyes

Theses and Dissertations

The bladder wall consists primarily of detrusor smooth muscle. Tension-sensitive nerves in the bladder wall are responsible for providing bladder fullness information that is interpreted as urgency. Bladder wall tension, and therefore nerve output, is a function of bladder volume, shape and material properties. Studies have shown that the bladder wall exhibits acutely regulated detrusor compliance. In addition, bladder shape throughout filling depends on intra-abdominal forces and material properties of the bladder wall, such as regulated detrusor compliance. This thesis focused on modeling the potential influence of acute changes in bladder compliance, shape and bladder wall tension during filling. Laplace’s …