Full-Text Articles in Mechanical Engineering
Phase-Field Modeling Of The Polymer Membrane Formation Process For Micro- And Ultra-Filtration, Michael Rosario Cervellere
Phase-Field Modeling Of The Polymer Membrane Formation Process For Micro- And Ultra-Filtration, Michael Rosario Cervellere
Graduate Theses and Dissertations
Porous polymer membrane filters are widely used in separation and filtration process. Micro- and ultra-filtration membranes are commonly used in biopharmaceutical applications such as filtering viruses and separating proteins from a carrier solution. The formation of these membrane filters via phase inversion is a complex and interconnected process where varying casting conditions can have a wide variety of effects on the final membrane morphol- ogy. Tailoring membrane filters for specific performance characteristics is a tedious and time consuming process. The time and length scales of membrane formation make it extremely difficult to experimentally observe membrane formation. Modeling the membrane formation …
Development Of Microdialysis Probes In Series Approach Toward Eliminating Microdialysis Sampling Calibration: Miniaturization Into A Pdms Microfluidic Device, Randy Espinal Cabrera
Development Of Microdialysis Probes In Series Approach Toward Eliminating Microdialysis Sampling Calibration: Miniaturization Into A Pdms Microfluidic Device, Randy Espinal Cabrera
Graduate Theses and Dissertations
A new microdialysis sampling method and microfluidic device were developed in vitro. The method consisted of using up to four microdialysis sampling probes connected in series to evaluate the relative recovery (RR) of different model solutes methyl orange, fluorescein isothiocyanate (FITC)-dextran average mol. wt. 4,000 (FITC-4), FITC-10, FITC-20, and FITC-40. Different flow rates (0.8, 1.0, and 1.5 µL/min) were used to compare experimentally observed relative recoveries with theoretical estimations. With increasing the number of probes in series, the relative recovery increases and ~100% (99.7% ± 0.9%) relative recovery for methyl orange was obtained. For larger molecules such as fluorescein isothiocyanate …
Factors Affecting Redox Magnetohydrodynamics For Flow In Small Volumes, Matthew D. Gerner
Factors Affecting Redox Magnetohydrodynamics For Flow In Small Volumes, Matthew D. Gerner
Graduate Theses and Dissertations
Lab-on-a-chip technologies offer the possibility of developing analytical devices that are low-cost, portable, disposable, fast, and operable by non-technical personnel. Such devices require automated methods to manipulate ultra-small volumes (picoliters) of samples and solution, including pumping, stirring, and positioning. Current methods for ultra-small volume microfluidics have limitations that restrict their use including high voltage requirements, disadvantageous flow profiles or rates, and relatively complicated fabrication due to mechanical parts. Redox magnetohydrodyanmics (RMHD) that utilizes permanent magnets for portability shows promise as a micropump with ease of switching flow direction, no moving parts, compatibility with both aqueous and non-aqueous solutions, low voltages …