Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Mechanical Engineering

Measurements Of Nh3 Linestrengths And Collisional Broadening Coefficients In N2, O2, Co2, And H2o Near 1103.46 Cm−1, Kyle Owen, Et-Touhami Es-Sebbar, Aamir Farooq Feb 2013

Measurements Of Nh3 Linestrengths And Collisional Broadening Coefficients In N2, O2, Co2, And H2o Near 1103.46 Cm−1, Kyle Owen, Et-Touhami Es-Sebbar, Aamir Farooq

Dr. Et-touhami Es-sebbar

Laser-based ammonia gas sensors have useful applications in many fields including combustion, atmospheric monitoring, and medical diagnostics. Calibration-free trace gas sensors require the spectroscopic parameters including linestrengths and collisional broadening coefficients to be known. Ammonia's strong ν2 vibrational band between View the MathML source has the high absorption strength needed for sensing small concentrations. Within this band, the 1103.46 cm−1 feature is one of the strongest and has minimal interference from CO2 and H2O. However, the six rotational transitions that make up this feature have not been studied previously with absorption spectroscopy due to their small line spacing ranging from …


Green Scheduling For Radiant Systems In Buildings, Truong X. Nghiem, Madhur Behl, George J. Pappas, Rahul Mangharam Jan 2013

Green Scheduling For Radiant Systems In Buildings, Truong X. Nghiem, Madhur Behl, George J. Pappas, Rahul Mangharam

Truong X Nghiem

In this report we look at the problem of peak power reduction for buildings with electric radiant floor heating systems. Uncoordinated operation of a multi-zone radiant floor heating system can result in temporally correlated electricity demand surges or peaks in the building’s electricity consumption. As peak power prices are 200-400 times that of the nominal rate, this uncoordinated activity can result in high electricity costs and expensive system operation. We have previously presented green scheduling as an approach for reducing the aggregate peak power consumption in buildings while ensuring that indoor thermal comfort is always maintained. This report extends the …


Effects Of N2o And O2 Addition To Nitrogen Townsend Dielectric Barrier Discharges At Atmospheric Pressure On The Absolute Ground-State Atomic Nitrogen Density, Et. Es-Sebbar, N. Gherardi, F. Massines Jan 2013

Effects Of N2o And O2 Addition To Nitrogen Townsend Dielectric Barrier Discharges At Atmospheric Pressure On The Absolute Ground-State Atomic Nitrogen Density, Et. Es-Sebbar, N. Gherardi, F. Massines

Dr. Et-touhami Es-sebbar

Absolute ground-state density of nitrogen atoms N (2p3 4S3/2) in non-equilibrium Townsend dielectric barrier discharges (TDBDs) at atmospheric pressure sustained in N2/N2O and N2/O2 gas mixtures has been measured using Two-photon absorption laser-induced fluorescence (TALIF) spectroscopy. The quantitative measurements have been obtained by TALIF calibration using krypton as a reference gas. We previously reported that the maximum of N (2p3 4S3/2) atom density is around 3 × 1014 cm−3 in pure nitrogen TDBD, and that this maximum depends strongly on the mean energy dissipated in the gas. In the two gas mixtures studied here, results show that the absolute N …


Performance Investigation Of A Hybrid Renewable Power Generation And Storage System Using Systemic Power Management Models, Damianos Giaouris, Athanasios Papadopoulos, Chrysa Ziogou, Dimiptris Ipsakis, Spyors Voutetakis, Simira Papadopoulou, Panos Seferlis, Fotis Stergiopoulos, Costas Elmasides Dec 2012

Performance Investigation Of A Hybrid Renewable Power Generation And Storage System Using Systemic Power Management Models, Damianos Giaouris, Athanasios Papadopoulos, Chrysa Ziogou, Dimiptris Ipsakis, Spyors Voutetakis, Simira Papadopoulou, Panos Seferlis, Fotis Stergiopoulos, Costas Elmasides

Sakis Papadopoulos

Hybrid renewable power generation systems considering storage of energy and/or hydrogen involve considerable complexity as heterogeneous equipment need to be interconnected and activated or deactivated at different time instances. This work employs generic and flexible decision making models to develop complex power/hydrogen management strategies and investigate their performance on systems integrating multiple power generation and storage devices. These models significantly facilitate the analysis of both a standalone power generation and storage system forming a microgrid currently in operation as well as three interconnected microgrids of different functionalities considered in this work. These systems are used to investigate the performance of …


Temperature-Dependent Absorption Cross-Section Measurements Of 1-Butene (1-C4h8) In Vuv And Ir, Et-Touhami Es-Sebbar, Yves Benilan, Aamir Farooq Dec 2012

Temperature-Dependent Absorption Cross-Section Measurements Of 1-Butene (1-C4h8) In Vuv And Ir, Et-Touhami Es-Sebbar, Yves Benilan, Aamir Farooq

Dr. Et-touhami Es-sebbar

Vacuum ultraviolet (VUV) and infrared (IR) absorption cross-section measurements of 1-butene (1-C4H8; CH2=CHCH2CH3; Butylene) are reported over the temperature range of 296–529 K. The VUV measurements are performed between 115 and 205 nm using synchrotron radiation as a tunable VUV light source. Fourier Transform Infrared (FTIR) spectroscopy is employed to measure absorption cross-section and band strengths in the IR region between 1.54 and 25 μm (∼6500–400 cm−1). The measured room-temperature VUV and IR absorption cross-sections are compared with available literature data and are found to be in good agreement. The oscillator strength for the electronic transition (A1A′→X1A′) around 150–205 nm …