Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 13 of 13

Full-Text Articles in Mechanical Engineering

Conditions For Capacitor Voltage Regulation In A Five-Level Cascade Multilevel Inverter: Application To Voltage-Boost In A Pm Drive, John Chiasson, Burak Ozpineci, Zhong Du, Leon Tolbert Dec 2013

Conditions For Capacitor Voltage Regulation In A Five-Level Cascade Multilevel Inverter: Application To Voltage-Boost In A Pm Drive, John Chiasson, Burak Ozpineci, Zhong Du, Leon Tolbert

Burak Ozpineci

A cascade multilevel inverter is a power electronic device built to synthesize a desired AC voltage from several levels of DC voltages. Such inverters have been the subject of research in the last several years, where the DC levels were considered to be identical in that all of them were either batteries, solar cells, etc. Similar to previous results in the literature, the work here shows how a cascade multilevel inverter can be used to obtain a voltage boost at higher speeds for a three-phase PM drive using only a single DC voltage source. The input of a standard three-leg …


A Five-Level Three-Phase Hybrid Cascade Multilevel Inverter Using A Single Dc Source For A Pm Synchronous Motor Drive, John N. Chiasson, Burak Ozpineci, Leon M. Tolbert Dec 2013

A Five-Level Three-Phase Hybrid Cascade Multilevel Inverter Using A Single Dc Source For A Pm Synchronous Motor Drive, John N. Chiasson, Burak Ozpineci, Leon M. Tolbert

Burak Ozpineci

The interest here is in using a single DC power source to construct a 3-phase 5-level cascade multilevel inverter to be used as a drive for a PM traction motor. The 5-level inverter consists of a standard 3-leg inverter (one leg for each phase) and an H-bridge in series with each inverter leg, which use a capacitor as a DC source. It is shown that one can simultaneously maintain the regulation of the capacitor voltage while achieving an output voltage waveform which is 25% higher than that obtained using a standard 3-leg inverter by itself.


Development Of A Novel Handheld Device For Active Compensation Of Physiological Tremor, Abhijit Saxena Jul 2013

Development Of A Novel Handheld Device For Active Compensation Of Physiological Tremor, Abhijit Saxena

Abhijit Saxena

In microsurgery, the human hand imposes certain limitations in accurately positioning the tip of a device such as scalpel. Any errors in the motion of the hand make microsurgical procedures difficult and involuntary motions such as hand tremors can make some procedures significantly difficult to perform. This is particularly true in the case of vitreoretinal microsurgery. The most familiar source of involuntary motion is physiological tremor. Real-time compensation of tremor is, therefore, necessary to assist surgeons to precisely position and manipulate the tool-tip to accurately perform a microsurgery. In this thesis, a novel handheld device (AID) is described for compensation …


Sugarmap: Location-Less Coverage For Micro-Aerial Sensing Swarms, Aveek Purohit, Zheng Sun, Pei Zhang Apr 2013

Sugarmap: Location-Less Coverage For Micro-Aerial Sensing Swarms, Aveek Purohit, Zheng Sun, Pei Zhang

Zheng Sun

No abstract provided.


Measurements Of Nh3 Linestrengths And Collisional Broadening Coefficients In N2, O2, Co2, And H2o Near 1103.46 Cm−1, Kyle Owen, Et-Touhami Es-Sebbar, Aamir Farooq Feb 2013

Measurements Of Nh3 Linestrengths And Collisional Broadening Coefficients In N2, O2, Co2, And H2o Near 1103.46 Cm−1, Kyle Owen, Et-Touhami Es-Sebbar, Aamir Farooq

Dr. Et-touhami Es-sebbar

Laser-based ammonia gas sensors have useful applications in many fields including combustion, atmospheric monitoring, and medical diagnostics. Calibration-free trace gas sensors require the spectroscopic parameters including linestrengths and collisional broadening coefficients to be known. Ammonia's strong ν2 vibrational band between View the MathML source has the high absorption strength needed for sensing small concentrations. Within this band, the 1103.46 cm−1 feature is one of the strongest and has minimal interference from CO2 and H2O. However, the six rotational transitions that make up this feature have not been studied previously with absorption spectroscopy due to their small line spacing ranging from …


Ultra-Thin-Film Aln Contour-Mode Resonators For Sensing Applications, Matteo Rinaldi, Chiara Zuniga, Gianluca Piazza Feb 2013

Ultra-Thin-Film Aln Contour-Mode Resonators For Sensing Applications, Matteo Rinaldi, Chiara Zuniga, Gianluca Piazza

Matteo Rinaldi

This paper reports on the design and experimental verification of a new class of ultra-thin-film (250 nm) aluminum nitride (AlN) microelectromechanical system (MEMS) contour mode resonators (CMRs) suitable for the fabrication of ultra-sensitive gravimetric sensors. The device thickness was opportunely scaled in order to increase the mass sensitivity, while keeping a constant frequency of operation. In this first demonstration the resonance frequency of the device was set to 178 MHz and a mass sensitivity as high as 38.96 KHz⋅μm2/fg was attained. This device demonstrates the unique capability of the CMR-S technology to decouple resonance frequency from mass sensitivity.


5-10 Ghz Aln Contour-Mode Nanoelectromechanical Resonators, Matteo Rinaldi, Chiara Zuniga, Gianluca Piazza Feb 2013

5-10 Ghz Aln Contour-Mode Nanoelectromechanical Resonators, Matteo Rinaldi, Chiara Zuniga, Gianluca Piazza

Matteo Rinaldi

This paper reports on the design and experimental verification of Super High Frequency (SHF) laterally vibrating NanoElctroMechanical (NEMS) resonators. For the first time, AlN piezoelectric nanoresonators with multiple frequencies of operation ranging between 5 and 10 GHz have been fabricated on the same chip and attained the highest f-Q product (4.6E12 Hz) ever reported in AlN contour-mode devices. These piezoelectric NEMS resonators are the first of their class to demonstrate on-chip sensing and actuation of nanostructures without the need of cumbersome or power consuming excitation and readout systems. Effective piezoelectric activity has been demonstrated in thin AlN films having vertical …


Nanoenabled Microelectromechanical Sensor For Volatile Organic Chemical Detection, Chiara Zuniga, Matteo Rinaldi, Samuel M. Khamis, A. T. Johnson, Gianluca Piazza Feb 2013

Nanoenabled Microelectromechanical Sensor For Volatile Organic Chemical Detection, Chiara Zuniga, Matteo Rinaldi, Samuel M. Khamis, A. T. Johnson, Gianluca Piazza

Matteo Rinaldi

A nanoenabled gravimetric chemical sensor prototype based on the large scale integration of single-stranded DNA (ss-DNA) decorated single-walled carbon nanotubes (SWNTs) as nanofunctionalization layer for aluminum nitride contour-mode resonant microelectromechanical (MEM) gravimetric sensors has been demonstrated. The capability of two distinct single strands of DNA bound to SWNTs to enhance differently the adsorption of volatile organic compounds such as dinitroluene (simulant for explosive vapor) and dymethyl-methylphosphonate (simulant for nerve agent sarin) has been verified experimentally. Different levels of sensitivity (17.3 and 28 KHz µm^2/fg) due to separate frequencies of operation (287 and 450 MHz) on the same die have also …


Super-High-Frequency Two-Port Aln Contour-Mode Resonators For Rf Applications, Matteo Rinaldi, Chiara Zuniga, Chengjie Zuo, Gianluca Piazza Feb 2013

Super-High-Frequency Two-Port Aln Contour-Mode Resonators For Rf Applications, Matteo Rinaldi, Chiara Zuniga, Chengjie Zuo, Gianluca Piazza

Matteo Rinaldi

This paper reports on the design and experimental verification of a new class of thin-film (250 nm) superhigh- frequency laterally-vibrating piezoelectric microelectromechanical (MEMS) resonators suitable for the fabrication of narrow-band MEMS filters operating at frequencies above 3 GHz. The device dimensions have been opportunely scaled both in the lateral and vertical dimensions to excite a contourextensional mode of vibration in nanofeatures of an ultra-thin (250 nm) AlN film. In this first demonstration, 2-port resonators vibrating up to 4.5 GHz have been fabricated on the same die and attained electromechanical coupling, kt^2, in excess of 1.5%. These devices are employed to …


Green Scheduling For Radiant Systems In Buildings, Truong X. Nghiem, Madhur Behl, George J. Pappas, Rahul Mangharam Jan 2013

Green Scheduling For Radiant Systems In Buildings, Truong X. Nghiem, Madhur Behl, George J. Pappas, Rahul Mangharam

Truong X Nghiem

In this report we look at the problem of peak power reduction for buildings with electric radiant floor heating systems. Uncoordinated operation of a multi-zone radiant floor heating system can result in temporally correlated electricity demand surges or peaks in the building’s electricity consumption. As peak power prices are 200-400 times that of the nominal rate, this uncoordinated activity can result in high electricity costs and expensive system operation. We have previously presented green scheduling as an approach for reducing the aggregate peak power consumption in buildings while ensuring that indoor thermal comfort is always maintained. This report extends the …


Effects Of N2o And O2 Addition To Nitrogen Townsend Dielectric Barrier Discharges At Atmospheric Pressure On The Absolute Ground-State Atomic Nitrogen Density, Et. Es-Sebbar, N. Gherardi, F. Massines Jan 2013

Effects Of N2o And O2 Addition To Nitrogen Townsend Dielectric Barrier Discharges At Atmospheric Pressure On The Absolute Ground-State Atomic Nitrogen Density, Et. Es-Sebbar, N. Gherardi, F. Massines

Dr. Et-touhami Es-sebbar

Absolute ground-state density of nitrogen atoms N (2p3 4S3/2) in non-equilibrium Townsend dielectric barrier discharges (TDBDs) at atmospheric pressure sustained in N2/N2O and N2/O2 gas mixtures has been measured using Two-photon absorption laser-induced fluorescence (TALIF) spectroscopy. The quantitative measurements have been obtained by TALIF calibration using krypton as a reference gas. We previously reported that the maximum of N (2p3 4S3/2) atom density is around 3 × 1014 cm−3 in pure nitrogen TDBD, and that this maximum depends strongly on the mean energy dissipated in the gas. In the two gas mixtures studied here, results show that the absolute N …


Performance Investigation Of A Hybrid Renewable Power Generation And Storage System Using Systemic Power Management Models, Damianos Giaouris, Athanasios Papadopoulos, Chrysa Ziogou, Dimiptris Ipsakis, Spyors Voutetakis, Simira Papadopoulou, Panos Seferlis, Fotis Stergiopoulos, Costas Elmasides Dec 2012

Performance Investigation Of A Hybrid Renewable Power Generation And Storage System Using Systemic Power Management Models, Damianos Giaouris, Athanasios Papadopoulos, Chrysa Ziogou, Dimiptris Ipsakis, Spyors Voutetakis, Simira Papadopoulou, Panos Seferlis, Fotis Stergiopoulos, Costas Elmasides

Sakis Papadopoulos

Hybrid renewable power generation systems considering storage of energy and/or hydrogen involve considerable complexity as heterogeneous equipment need to be interconnected and activated or deactivated at different time instances. This work employs generic and flexible decision making models to develop complex power/hydrogen management strategies and investigate their performance on systems integrating multiple power generation and storage devices. These models significantly facilitate the analysis of both a standalone power generation and storage system forming a microgrid currently in operation as well as three interconnected microgrids of different functionalities considered in this work. These systems are used to investigate the performance of …


Temperature-Dependent Absorption Cross-Section Measurements Of 1-Butene (1-C4h8) In Vuv And Ir, Et-Touhami Es-Sebbar, Yves Benilan, Aamir Farooq Dec 2012

Temperature-Dependent Absorption Cross-Section Measurements Of 1-Butene (1-C4h8) In Vuv And Ir, Et-Touhami Es-Sebbar, Yves Benilan, Aamir Farooq

Dr. Et-touhami Es-sebbar

Vacuum ultraviolet (VUV) and infrared (IR) absorption cross-section measurements of 1-butene (1-C4H8; CH2=CHCH2CH3; Butylene) are reported over the temperature range of 296–529 K. The VUV measurements are performed between 115 and 205 nm using synchrotron radiation as a tunable VUV light source. Fourier Transform Infrared (FTIR) spectroscopy is employed to measure absorption cross-section and band strengths in the IR region between 1.54 and 25 μm (∼6500–400 cm−1). The measured room-temperature VUV and IR absorption cross-sections are compared with available literature data and are found to be in good agreement. The oscillator strength for the electronic transition (A1A′→X1A′) around 150–205 nm …