Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 14 of 14

Full-Text Articles in Mechanical Engineering

Machine Learning Approach To Activity Categorization In Young Adults Using Biomechanical Metrics, Nathan Q. C. Holland Oct 2023

Machine Learning Approach To Activity Categorization In Young Adults Using Biomechanical Metrics, Nathan Q. C. Holland

Mechanical & Aerospace Engineering Theses & Dissertations

Inactive adults often have decreased musculoskeletal health and increased risk factors for chronic diseases. However, there is limited data linking biomechanical measurements of generally healthy young adults to their physical activity levels assessed through questionnaires. Commonly used data collection methods in biomechanics for assessing musculoskeletal health include but are not limited to muscle quality (measured as echo intensity when using ultrasound), isokinetic (i.e., dynamic) muscle strength, muscle activations, and functional movement assessments using motion capture systems. These assessments can be time consuming for both data collection and processing. Therefore, understanding if all biomechanical assessments are necessary to classify the activity …


A Review Of Piezoelectric Footwear Energy Harvesters: Principles, Methods, And Applications, Bingqi Zhao, Feng Qian, Alexander Hatfield, Lei Zuo, Tian-Bing Xu Jan 2023

A Review Of Piezoelectric Footwear Energy Harvesters: Principles, Methods, And Applications, Bingqi Zhao, Feng Qian, Alexander Hatfield, Lei Zuo, Tian-Bing Xu

Mechanical & Aerospace Engineering Faculty Publications

Over the last couple of decades, numerous piezoelectric footwear energy harvesters (PFEHs) have been reported in the literature. This paper reviews the principles, methods, and applications of PFEH technologies. First, the popular piezoelectric materials used and their properties for PEEHs are summarized. Then, the force interaction with the ground and dynamic energy distribution on the footprint as well as accelerations are analyzed and summarized to provide the baseline, constraints, potential, and limitations for PFEH design. Furthermore, the energy flow from human walking to the usable energy by the PFEHs and the methods to improve the energy conversion efficiency are presented. …


Drive Leg And Stride Leg Ground Reaction Forces Relationship To Medial Elbow Stress And Velocity In Collegiate Baseball Pitchers, Brett Smith Apr 2021

Drive Leg And Stride Leg Ground Reaction Forces Relationship To Medial Elbow Stress And Velocity In Collegiate Baseball Pitchers, Brett Smith

Biomedical Engineering Theses & Dissertations

This study examines several different kinetic variables in relation to pitch velocity and elbow varus torque in collegiate baseball pitchers using force plates, an inertial measurement unit, and a radar unit. The purpose of this study is to investigate the kinetic variables being measured and their relationship to pitch velocity and loads being placed on the medial elbow. Twelve collegiate baseball pitchers participated in this study, which was approved by the IRB. Impulse of the drive leg in the anterior-posterior direction, stride leg peak force in the anterior-posterior (AP) direction, elbow varus torque, and pitch velocity were all measured. Two …


Mechanism For The Unfolding Of The Top7 Protein In Steered Molecular Dynamics Simulations As Revealed By Mutual Information Analysis, Ognjen Perišić, Willy Wriggers Jan 2021

Mechanism For The Unfolding Of The Top7 Protein In Steered Molecular Dynamics Simulations As Revealed By Mutual Information Analysis, Ognjen Perišić, Willy Wriggers

Mechanical & Aerospace Engineering Faculty Publications

We employed mutual information (MI) analysis to detect motions affecting the mechanical resistance of the human-engineered protein Top7. The results are based on the MI analysis of pair contact correlations measured in steered molecular dynamics (SMD) trajectories and their statistical dependence on global unfolding. This study is the first application of the MI analysis to SMD forced unfolding, and we furnish specific SMD recommendations for the utility of parameters and options in the TimeScapes package. The MI analysis provided a global overview of the effect of perturbation on the stability of the protein. We also employed a more conventional trajectory …


Computational Analysis And Design Optimization Of Convective Pcr Devices, Jung Il Shu Jul 2019

Computational Analysis And Design Optimization Of Convective Pcr Devices, Jung Il Shu

Mechanical & Aerospace Engineering Theses & Dissertations

Polymerase Chain Reaction (PCR) is a relatively novel technique to amplify a few copies of DNA to a detectable level. PCR has already become common in biomedical research, criminal forensics, molecular archaeology, and so on. Many have attempted to develop PCR devices in numerous types for the purpose of the lab-on-chip (LOC) or point-of-care (POC). To use PCR devices for POC lab testing, the price must be lower, and the performance should be comparable to the lab devices. For current practices with the existing methods, the price is pushed up higher partially due to too much dependence on numerous developmental …


Understanding The Mechanical Behavior Of Costal Cartilage At Their Curved Exterior Surface Via A Tactile Sensor With A Built-In Probe For Distributed-Deflection Detection, Jiayue Shen Apr 2018

Understanding The Mechanical Behavior Of Costal Cartilage At Their Curved Exterior Surface Via A Tactile Sensor With A Built-In Probe For Distributed-Deflection Detection, Jiayue Shen

Mechanical & Aerospace Engineering Theses & Dissertations

This dissertation is aimed to determine the mechanical properties at the exterior surface of costal cartilages (CC) and examine how they vary with the cartilage length and the anatomical sites of CC in the ribcage via conformal indentation testing which is built upon a tactile sensor for distributed-deflection detection. The sensor entails a rectangular Polydimethylsiloxane (PDMS) microstructure sensing-plate integrated with a 5 ×1 transducer array with 0.75mm spatial resolution underneath and a built-in probe of 0.5mm×5mm×3mm above. By pressing the sensor against the exterior surface of a CC tissue with a pre-defined indentation pattern, the sensor conforms to the curved …


Radial And Longitudinal Motion Of The Arterial Wall: Their Relation To Pulsatile Pressure And Flow In The Artery, Dan Wang, Linda Vahala, Zhili Hao Jan 2018

Radial And Longitudinal Motion Of The Arterial Wall: Their Relation To Pulsatile Pressure And Flow In The Artery, Dan Wang, Linda Vahala, Zhili Hao

Mechanical & Aerospace Engineering Faculty Publications

The aim of this paper is to analyze the radial and longitudinal motion of the arterial wall in the context of pulsatile pressure and flow, and to understand their physiological implications for the cardiovascular system. A reexamination of the well-established one-dimensional governing equations for axial blood flow in the artery and the constitutive equation for the radial dilation of the arterial wall shows that two waves—a pulsatile pressure wave in the artery and a radial displacement wave in the arterial wall—propagate simultaneously along the arterial tree with the same propagation velocity, explaining why this velocity combines the physical properties and …


The Effect Of Bone And Ligament Morphology Of Ankle Joint Loading In The Neutral Position, Jinhyuk Kim Jul 2017

The Effect Of Bone And Ligament Morphology Of Ankle Joint Loading In The Neutral Position, Jinhyuk Kim

Mechanical & Aerospace Engineering Theses & Dissertations

Computational modeling of joints is used to investigate the effect of injuries, to plan surgeries, and to answer questions about joints that cannot be answered experimentally. Existing models of the ankle joint are moving toward being able to model specific patients, however, they do not include all of the anatomy (e.g., bones and/or ligaments) and have restrictive boundary conditions. These simplification in anatomy are made to minimize pre-processing and computation time. Because biomechanical modeling is increasingly focused on the implementation of patient specific cases, the effects of including more anatomical structures and determining how they affect the model results is …


Biophysical Tools To Study Cellular Mechanotransduction, Ismeel Muhamed, Farhan Chowdhury, Venkat Maruthamuthu Feb 2017

Biophysical Tools To Study Cellular Mechanotransduction, Ismeel Muhamed, Farhan Chowdhury, Venkat Maruthamuthu

Mechanical & Aerospace Engineering Faculty Publications

The cell membrane is the interface that volumetrically isolates cellular components from the cell's environment. Proteins embedded within and on the membrane have varied biological functions: reception of external biochemical signals, as membrane channels, amplification and regulation of chemical signals through secondary messenger molecules, controlled exocytosis, endocytosis, phagocytosis, organized recruitment and sequestration of cytosolic complex proteins, cell division processes, organization of the cytoskeleton and more. The membrane's bioelectrical role is enabled by the physiologically controlled release and accumulation of electrochemical potential modulating molecules across the membrane through specialized ion channels (e.g., Na, Ca2+, K channels). …


A Retrospective Study Of Amusement Ride Restraint And Containment Systems: Identifying Design Challenges For Statistically Rare Anthropometric Cases, Paula M. Stenzler Apr 2016

A Retrospective Study Of Amusement Ride Restraint And Containment Systems: Identifying Design Challenges For Statistically Rare Anthropometric Cases, Paula M. Stenzler

Engineering Management & Systems Engineering Theses & Dissertations

The intent of this project was to conduct a retrospective study of amusement ride restraint and containment systems’ failures to identify the challenges associated with existing design criteria to safely accommodate statistically rare groups that fall outside amusement industry standards. Innovations in ride technology provide an opportunity for injuries to occur if restraint and containment systems cannot properly accommodate unique patron anthropometry. It is paramount to understand how anthropometric features contribute to the patron’s ability to defeat ride restraint and containment systems. A systemic perspective was used based on industry accident data to frame the problem associated with restraint and …


Computational Assessment Of Neural Probe And Brain Tissue Interface Under Transient Motion, Michael Polanco, Sebastian Bawab, Hangsoon Yoon Jan 2016

Computational Assessment Of Neural Probe And Brain Tissue Interface Under Transient Motion, Michael Polanco, Sebastian Bawab, Hangsoon Yoon

Mechanical & Aerospace Engineering Faculty Publications

The functional longevity of a neural probe is dependent upon its ability to minimize injury risk during the insertion and recording period in vivo, which could be related to motion-related strain between the probe and surrounding tissue. A series of finite element analyses was conducted to study the extent of the strain induced within the brain in an area around a neural probe. This study focuses on the transient behavior of neural probe and brain tissue interface with a viscoelastic model. Different stages of the interface from initial insertion of neural probe to full bonding of the probe by astro-glial …


Implementation Of Analytical Fatigue Models Into Opensim To Predict The Effects Of Fatigue On Anterior Cruciate Ligament Loading, Michael A. Samann Jul 2014

Implementation Of Analytical Fatigue Models Into Opensim To Predict The Effects Of Fatigue On Anterior Cruciate Ligament Loading, Michael A. Samann

Mechanical & Aerospace Engineering Theses & Dissertations

The anterior cruciate ligament (ACL) provides stability to the knee joint while performing activities such as a side step cut. Neuromuscular fatigue, a reduction in muscle force producing capabilities, alters lower extremity mechanics while performing a side step cut and may increase the risk of ACL injury, particularly in females. Musculoskeletal modeling allows for the measurement of muscle forces, which are difficult to measure in-vivo. Therefore, musculoskeletal modeling, may improve our understanding of the effects of neuromuscular fatigue on muscle force production and loading of the ACL. Therefore, the purpose of this study was to develop a musculoskeletal model which …


Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren Jan 2013

Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren

Mechanical & Aerospace Engineering Faculty Publications

A three-dimensional (3D) computational fluid dynamics study of shear rates around distal end-to-side anastomoses has been conducted. Three 51% and three 75% cross-sectional area-reduced 6 mm cylinders were modeled each with a bypass cylinder attached at a 30-degree angle at different placements distal to the constriction. Steady, incompressible, Newtonian blood flow was assumed, and the full Reynolds-averaged Navier-Stokes equations, turbulent kinetic energy, and specific dissipation rate equations were solved on a locally structured multiblock mesh with hexahedral elements. Consequently, distal placement of an end-to-side bypass graft anastomosis was found to have an influence on the shear rate magnitudes. For the …


Shaken Baby Syndrome: Retinal Hemorrhaging. A Biomechanical Approach To Understanding The Mechanism Of Causation, Steven Alex Hans Jul 2007

Shaken Baby Syndrome: Retinal Hemorrhaging. A Biomechanical Approach To Understanding The Mechanism Of Causation, Steven Alex Hans

Mechanical & Aerospace Engineering Theses & Dissertations

Shaken Baby Syndrome (SBS) is a form of abuse where typically an infant, age six months or less, is held and shaken. There may or may not be direct impact associated with this action. Further, there is very little agreement on the actual mechanism of SBS. Clinical studies are limited in showing the exact mechanism of injury and only offer postulations and qualitative descriptions. SBS has received much attention in the media, has resulted in a great deal of litigation and can be the source of unfounded accusations. Therefore, it is necessary to try to quantify the forces that may …