Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 17 of 17

Full-Text Articles in Mechanical Engineering

Low Shear In Short-Term Impacts Endothelial Cell Traction And Alignment In Long-Term, Mohanish Chandurkar, Nikhil Mittal, Shaina P. Royer-Weeden, Steven D. Lehmann, Yeonwoo Rho, Sangyoon J. Han Feb 2024

Low Shear In Short-Term Impacts Endothelial Cell Traction And Alignment In Long-Term, Mohanish Chandurkar, Nikhil Mittal, Shaina P. Royer-Weeden, Steven D. Lehmann, Yeonwoo Rho, Sangyoon J. Han

Michigan Tech Publications, Part 2

Within the vascular system, endothelial cells (ECs) are exposed to fluid shear stress (FSS), a mechanical force exerted by blood flow that is critical for regulating cellular tension and maintaining vascular homeostasis. The way ECs react to FSS varies significantly; while high, laminar FSS supports vasodilation and suppresses inflammation, low or disturbed FSS can lead to endothelial dysfunction and increase the risk of cardiovascular diseases. Yet, the adaptation of ECs to dynamically varying FSS remains poorly understood. This study focuses on the dynamic responses of ECs to brief periods of low FSS, examining its impact on endothelial traction-a measure of …


Low Shear In Short-Term Impacts Endothelial Cell Traction And Alignment In Long-Term, Mohanish K. Chandurkar, Nikhil Mittal, Shaina P. Royer-Weeden, Steven D. Lehmann, Yeonwoo Rho, Sangyoon J. Han Feb 2024

Low Shear In Short-Term Impacts Endothelial Cell Traction And Alignment In Long-Term, Mohanish K. Chandurkar, Nikhil Mittal, Shaina P. Royer-Weeden, Steven D. Lehmann, Yeonwoo Rho, Sangyoon J. Han

Michigan Tech Publications, Part 2

Within the vascular system, endothelial cells (ECs) are exposed to fluid shear stress (FSS), a mechanical force exerted by blood flow that is critical for regulating cellular tension and maintaining vascular homeostasis. The way ECs react to FSS varies significantly; while high, laminar FSS supports vasodilation and suppresses inflammation, low or disturbed FSS can lead to endothelial dysfunction and increase the risk of cardiovascular diseases. Yet, the adaptation of ECs to dynamically varying FSS remains poorly understood. This study focuses on the dynamic responses of ECs to brief periods of low FSS, examining its impact on endothelial traction—a measure of …


Polymerizing Actin Regulates Myosin-Independent Mechanosensing By Modulating Actin Elasticity And Flow Fluctuation, Nikhil Mittal, Etienne Michels, Kathleen Pakenas, Shaina P. Royer-Weeden, Sangyoon J. Han Jan 2024

Polymerizing Actin Regulates Myosin-Independent Mechanosensing By Modulating Actin Elasticity And Flow Fluctuation, Nikhil Mittal, Etienne Michels, Kathleen Pakenas, Shaina P. Royer-Weeden, Sangyoon J. Han

Michigan Tech Publications, Part 2

The stiffness of the extracellular matrix induces differential tension within integrin-based adhesions. However, it has been unclear if the stiffness-dependent differential tension is induced solely by myosin activity. Here, we report that in the absence of myosin contractility, 3T3 fibroblasts still transmit stiffness-dependent differential levels of traction. This myosin-independent differential traction is regulated by polymerizing actin assisted by actin nucleators Arp2/3 and formin where formin has stronger contribution than Arp2/3. Interestingly, we report a four-fold reduction in traction of cells when both Arp2/3 and myosin were inhibited, compared to cells with only myosin inhibition, while there was only a slight …


Myosin-Independent Stiffness Sensing By Fibroblasts Is Regulated By The Viscoelasticity Of Flowing Actin, Nikhil Mittal, Etienne B. Michels, Andrew E. Massey, Yunxiu Qiu, Shaina P. Royer-Weeden, Bryan R. Smith, Alexander X. Cartagena-Rivera, Sangyoon J. Han Jan 2024

Myosin-Independent Stiffness Sensing By Fibroblasts Is Regulated By The Viscoelasticity Of Flowing Actin, Nikhil Mittal, Etienne B. Michels, Andrew E. Massey, Yunxiu Qiu, Shaina P. Royer-Weeden, Bryan R. Smith, Alexander X. Cartagena-Rivera, Sangyoon J. Han

Michigan Tech Publications, Part 2

The stiffness of the extracellular matrix induces differential tension within integrin-based adhesions, triggering differential mechanoresponses. However, it has been unclear if the stiffness-dependent differential tension is induced solely by myosin activity. Here, we report that in the absence of myosin contractility, 3T3 fibroblasts still transmit stiffness-dependent differential levels of traction. This myosin-independent differential traction is regulated by polymerizing actin assisted by actin nucleators Arp2/3 and formin where formin has a stronger contribution than Arp2/3 to both traction and actin flow. Intriguingly, despite only slight changes in F-actin flow speed observed in cells with the combined inhibition of Arp2/3 and myosin …


Conductive 3d Nano-Biohybrid Systems Based On Densified Carbon Nanotube Forests And Living Cells, Roya Bagheri, Alicia K. Ball, Masoud Kasraie, Aparna Chandra, Xinqian Chen, Ibrahim Miskioglu, Zhiying Shan, Parisa Pour Shahid Saeed Abadi Jan 2023

Conductive 3d Nano-Biohybrid Systems Based On Densified Carbon Nanotube Forests And Living Cells, Roya Bagheri, Alicia K. Ball, Masoud Kasraie, Aparna Chandra, Xinqian Chen, Ibrahim Miskioglu, Zhiying Shan, Parisa Pour Shahid Saeed Abadi

Michigan Tech Publications, Part 2

Conductive biohybrid cell-material systems have applications in bioelectronics and biorobotics. To date, conductive scaffolds are limited to those with low electrical conductivity or 2D sheets. Here, 3D biohybrid conductive systems are developed using fibroblasts or cardiomyocytes integrated with carbon nanotube (CNT) forests that are densified due to interactions with a gelatin coating. CNT forest scaffolds with a height range of 120–240 µm and an average electrical conductivity of 0.6 S/cm are developed and shown to be cytocompatible as evidenced from greater than 89% viability measured by live-dead assay on both cells on day 1. The cells spread on top and …


An Experimentally Validated Computational Model For The Degradation And Fracture Of Magnesium-Based Implants In A Chemically Corrosive Environment, Mark M. Ousdigian Jan 2023

An Experimentally Validated Computational Model For The Degradation And Fracture Of Magnesium-Based Implants In A Chemically Corrosive Environment, Mark M. Ousdigian

Dissertations, Master's Theses and Master's Reports

In the orthopedic and cardiovascular fields there is a growing interest for biodegradable implants, which can be naturally degraded in the body environment over time so that no extraction surgery is required. These implants must be designed to maintain their strength until the fracture has healed in the body, which could be influenced by many factors such as -the patient’s age, activities, body weight, pre-existing conditions etc. Hence, an ideal implant design should be done on a patient-by-patient basis. In the present work, a computational model is developed to predict the degradation and fracture of magnesium-based implants in a stress-coupled …


The Economics Of Classroom 3-D Printing Of Open-Source Digital Designs Of Learning Aids, Nicole Gallup, Joshua M. Pearce Nov 2020

The Economics Of Classroom 3-D Printing Of Open-Source Digital Designs Of Learning Aids, Nicole Gallup, Joshua M. Pearce

Michigan Tech Publications

While schools struggle financially, capital for purchasing physical learning aids is often cut. To determine if costs could be reduced for learning aids, this study analyzed classroom-based distributed digital manufacturing using 3-D printing of open-source learning aid designs. Learning aid designs are analyzed in detail for their economic viability considering printing and assembly costs with purchased components and compared to equivalent or inferior commercial products available on Amazon. The results show current open-source 3-D printers are capable of manufacturing useful learning aids and that doing so provides high economic savings in the classroom. Overall, the average learning aid would save …


Parametric Nasopharyngeal Swab For Sampling Covid-19 And Other Respiratory Viruses: Open Source Design, Sla 3-D Printing And Uv Curing System, Nicole Gallup, Adam Pringle, Shane Oberloier, Nagendra Gautam Tanikella, Joshua M. Pearce May 2020

Parametric Nasopharyngeal Swab For Sampling Covid-19 And Other Respiratory Viruses: Open Source Design, Sla 3-D Printing And Uv Curing System, Nicole Gallup, Adam Pringle, Shane Oberloier, Nagendra Gautam Tanikella, Joshua M. Pearce

Michigan Tech Publications

Access to nasopharyngeal swabs for sampling remain a bottleneck in some regions for COVID19 testing. This study develops a distributed manufacturing solution using only an open source manufacturing tool chain consisting of two types of open source 3-D printing and batch UV curing, and provides a parametric fully free design of a nasopharyngeal swab. The swab was designed using parametric OpenSCAD in two components (a head with engineered break point and various handles), which has several advantages: i) minimizing print time on relatively slow SLA printers, ii) enabling the use of smaller print volume open source SLA printers, iii) reducing …


Tra-1-60-Positive/Cd45low Cells Found In The Peripheral Blood Of Prostate Cancer Patients With Metastatic Disease – A Proof-Of-Concept Study, Claudia Schäfer, Yawen Ju, Youngbin Tak, Cesar Vazquez, Sangyoon J. Han, Edwin Tan, Et Al. Jan 2020

Tra-1-60-Positive/Cd45low Cells Found In The Peripheral Blood Of Prostate Cancer Patients With Metastatic Disease – A Proof-Of-Concept Study, Claudia Schäfer, Yawen Ju, Youngbin Tak, Cesar Vazquez, Sangyoon J. Han, Edwin Tan, Et Al.

Michigan Tech Publications

Purpose

Over 90% of all cancer related deaths are due to metastasis. However, current diagnostic tools can't reliably discriminate between invasive and localized cancers.

Patients and methods

In this proof-of-concept study, we employed the embryonic stem cell marker TRA-1-60 (TRA+) to identify TRA + cells within the blood of prostate cancer patients and searched for TRA + cells in men with metastatic and localized cancers. We isolated whole peripheral blood mononuclear cells from 26 metastatic prostate cancer patients, from 13 patients with localized prostate cancer and from 17 healthy controls. Cells were stained for DAPI, CD45 and TRA + by …


3d Printing Of Iron Oxide Incorporated Polydimethylsiloxane Soft Magnetic Actuator, Rasoul Bayaniahangar Jan 2020

3d Printing Of Iron Oxide Incorporated Polydimethylsiloxane Soft Magnetic Actuator, Rasoul Bayaniahangar

Dissertations, Master's Theses and Master's Reports

Soft actuators have grown to be a topic of great scientific interest recently. As the fabrication of soft actuators with conventional microfabrication methods are tedious, expensive, and time consuming, employment of 3-D printing fabrication methods appears promising as they can simplify fabrication and reduce the production cost. Complex structures can be fabricated with 3-D printing such as helical coils can achieve actuation performances that otherwise would not be possible with simpler geometries. In this thesis development of soft magnetic helical coil actuators of iron-oxide embedded polydimethylsiloxane (PDMS) was achieved with embedded 3-D printing techniques. Composites with three different weight ratios …


3d Printing In Low Resource Healthcare Settings: Analysis Of Potential Implementations, Alenna Beroza Jan 2019

3d Printing In Low Resource Healthcare Settings: Analysis Of Potential Implementations, Alenna Beroza

Dissertations, Master's Theses and Master's Reports

3D printing has gained significant momentum in the past ten years, and its unique advantages make it especially ideal for use in low resource healthcare settings, where many designs have already been successfully implemented. Yet, little has been studied on how 3D printing can be sustainably and functionally implemented in low resource healthcare systems as a manufacturing practice. In this report, three business models are proposed for this implementation: In-House Operator, Independent Operator, and Print Farm. These models were then tested over four months in Kisumu county, Kenya, at two workshops and seven public hospitals. I worked with local medical …


Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop Jan 2019

Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop

Dissertations, Master's Theses and Master's Reports

The purpose of this research is to investigate the relationship between the mechanical impedance of the human ankle and the corresponding lower extremity muscle activity. Three experimental studies were performed to measure the ankle impedance about multiple degrees of freedom (DOF), while the ankle was subjected to different loading conditions and different levels of muscle activity. The first study determined the non-loaded ankle impedance in the sagittal, frontal, and transverse anatomical planes while the ankle was suspended above the ground. The subjects actively co-contracted their agonist and antagonistic muscles to various levels, measured using electromyography (EMG). An Artificial Neural Network …


A Hybrid-Powered Wireless System For Multiple Biopotential Monitoring, Shawn Li Jan 2019

A Hybrid-Powered Wireless System For Multiple Biopotential Monitoring, Shawn Li

Dissertations, Master's Theses and Master's Reports

Chronic diseases are the top cause of human death in the United States and worldwide. A huge amount of healthcare costs is spent on chronic diseases every year. The high medical cost on these chronic diseases facilitates the transformation from in-hospital to out-of-hospital healthcare. The out-of-hospital scenarios require comfortability and mobility along with quality healthcare. Wearable electronics for well-being management provide good solutions for out-of-hospital healthcare. Long-term health monitoring is a practical and effective way in healthcare to prevent and diagnose chronic diseases. Wearable devices for long-term biopotential monitoring are impressive trends for out-of-hospital health monitoring. The biopotential signals in …


Estimation And Prediction Of The Human Gait Dynamics For The Control Of An Ankle-Foot Prosthesis, Guilherme Aramizo Ribeiro Jan 2019

Estimation And Prediction Of The Human Gait Dynamics For The Control Of An Ankle-Foot Prosthesis, Guilherme Aramizo Ribeiro

Dissertations, Master's Theses and Master's Reports

With the growing population of amputees, powered prostheses can be a solution to improve the quality of life for many people. Powered ankle-foot prostheses can be made to behave similar to the lost limb via controllers that emulate the mechanical impedance of the human ankle. Therefore, the understanding of human ankle dynamics is of major significance. First, this work reports the modulation of the mechanical impedance via two mechanisms: the co-contraction of the calf muscles and a change of mean ankle torque and angle. Then, the mechanical impedance of the ankle was determined, for the first time, as a multivariable …


Computational Studies On Biomechanics Of Concussion And On Efficacy Of Football Helmets, David Labyak Jan 2017

Computational Studies On Biomechanics Of Concussion And On Efficacy Of Football Helmets, David Labyak

Dissertations, Master's Theses and Master's Reports

Football helmets have been used for many years to prevent head injuries to players. Over the years, the helmet design has evolved from a crude leather head covering to the more recent form fitting helmets that are seen today. The one design feature that has been common in the majority of all helmets is a hard polycarbonate shell with a foam cushion padding. The main goal of the padding layer was to reduce the amount of linear acceleration during an impact event. The one feature that has been overlooked is how stiff the padding is in rotation.

The purpose of …


Mechanical Impedance Of Ankle As A Function Of Electromyography Signals Of Lower Leg Muscles Using Artificial Neural Network, Chen Jia Jan 2015

Mechanical Impedance Of Ankle As A Function Of Electromyography Signals Of Lower Leg Muscles Using Artificial Neural Network, Chen Jia

Dissertations, Master's Theses and Master's Reports - Open

This paper reports on the feasibility of developing a model to describe the nonlinear relationship between the mechanical impedance of the human ankle within a specified range of frequency and the root mean square (RMS) value of the Electromyography (EMG) signals of the muscles of human ankle using Artificial Neural Network (ANN). A lower extremity rehabilitation robot — Anklebot was used to apply pseudo-random mechanical perturbations to the ankle and measure the angular displacement of the ankle to estimate the data of ankle mechanical impedance. Meanwhile, the surface EMG signals from the selected muscles were monitored and recorded using a …


A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari Jan 2014

A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari

Dissertations, Master's Theses and Master's Reports - Open

Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based …