Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences

2016

Institution
Keyword
Publication
Publication Type

Articles 1 - 18 of 18

Full-Text Articles in Mechanical Engineering

The Effect Of A Powered Ankle Foot Orthosis On Walking In A Stroke Subject: A Case Study, Ali Pourghasem, Ismail Ebrahimi Takamjani, Mohammad Taghi Karimi, Mohammad Kamali, Mohammad Jannesari, Iman Salafian Dec 2016

The Effect Of A Powered Ankle Foot Orthosis On Walking In A Stroke Subject: A Case Study, Ali Pourghasem, Ismail Ebrahimi Takamjani, Mohammad Taghi Karimi, Mohammad Kamali, Mohammad Jannesari, Iman Salafian

Department of Mechanical and Materials Engineering: Faculty Publications

[Purpose] Standing and walking are impaired in stroke patients. Therefore, assisted devices are required to restore their walking abilities. The ankle foot orthosis with an external powered source is a new type of orthosis. The aim of this study was to evaluate the performance of a powered ankle foot orthosis compared with unpowered orthoses in a stroke patient.

[Subjects and Methods] A single stroke subject participated in this study. The subject was fitted with three types of ankle foot orthosis (powered, posterior leg spring, and carbon ankle foot orthoses). He was asked to walk with and without the three types …


Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia Dec 2016

Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia

Mechanical Engineering Faculty Publications

Process parameters and post-processing heat treatment techniques have been developed to produce both shape memory and superelastic NiTi using Additive Manufacturing. By introducing engineered porosity, the stiffness of NiTi can be tuned to the level closely matching cortical bone. Using additively manufactured porous superelastic NiTi, we have proposed the use of patient-specific, stiffness-matched fixation hardware, for mandible skeletal reconstructive surgery. Currently, Ti-6Al-4V is the most commonly used material for skeletal fixation devices. Although this material offers more than sufficient strength for immobilization during the bone healing process, the high stiffness of Ti-6Al-4V implants can cause stress shielding. In this paper, …


Design Of A Modified Stewart Platform Manipulator For Misalignment Correction, Adekunle Ayoko Dec 2016

Design Of A Modified Stewart Platform Manipulator For Misalignment Correction, Adekunle Ayoko

Master of Technology Management Plan II Graduate Projects

This thesis work is about the design of a modified Stewart platform manipulator for misalignment correction. The common version of the Stewart platform uses six actuators. The traditional Stewart platform of this kind has a moving top plate and a fixed base plate. However, in this research, the modified design of the traditional Stewart platform is studied. It is designed to be an easy connect-disconnect platform that can wrap around different structures with different cross sections and symmetrically designed. It is able to adjust position easily by using four identical but independent linear actuators populated evenly in two parts fastened …


Final Design Report: Allergen Mixing Assistant (Ama) Micro-Refrigeration Redesigning, Mitchell Parks, Minwoo (Michael) Suh Dec 2016

Final Design Report: Allergen Mixing Assistant (Ama) Micro-Refrigeration Redesigning, Mitchell Parks, Minwoo (Michael) Suh

Mechanical Engineering

Abstract

Allergen Mixing Assistant (AMA) by Xtract Solutions is a device designed to more “effectively refrigerate, organize, and mix allergenic extracts”. Although Xtract Solutions intended the product to be fully automated, the company has decided against its automation and declared its current design as a minimum viable product whose components are too expensive, difficult to source and complex. Therefore, Cal Poly AMA design team - Mitchell Parks and Minwoo Suh - has decided to replace these expensive components with much more economical alternatives as shown below:

Stirling cooler

Thermoelectric (Peltier) cooler

Custom Arduino

Controller Card

TEC Thermostat *** …


The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin Dec 2016

The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin

UNLV Theses, Dissertations, Professional Papers, and Capstones

Many studies have demonstrated clinical applications for the use of dental pulp stem cells (DPSC) for the treatment of various conditions. This has driven medical and scientific interest in the collection, isolation and banking of DPSC tissues for research into these potential therapies. Few studies to date have evaluated the viability of DPSC following long-term cryopreservation. The purpose of this study is to evaluate the effects of cryopreservation on dental pulp-derived stem cells (DPSC) viability over a period of three years. Dental pulp-derived stem cells were isolated and cultured from thirty-one healthy teeth. DPSC isolates were assessed for doubling-time and …


Multi-Classifier Fusion Strategy For Activity And Intent Recognition Of Torso Movements, Abhijit Kadrolkar Nov 2016

Multi-Classifier Fusion Strategy For Activity And Intent Recognition Of Torso Movements, Abhijit Kadrolkar

Doctoral Dissertations

As assistive, wearable robotic devices are being developed to physically assist their users, it has become crucial to develop safe, reliable methods to coordinate the device with the intentions and motions of the wearer. This dissertation investigates the recognition of user intent during flexion and extension of the human torso in the sagittal plane to be used for control of an assistive exoskeleton for the human torso. A multi-sensor intent recognition approach is developed that combines information from surface electromyogram (sEMG) signals from the user’s muscles and inertial sensors mounted on the user’s body. Intent recognition is implemented by following …


Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee Aug 2016

Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee

The Summer Undergraduate Research Fellowship (SURF) Symposium

Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …


Modeling Picking On Pharmaceutical Tablets, Shrikant Swaminathan Aug 2016

Modeling Picking On Pharmaceutical Tablets, Shrikant Swaminathan

Open Access Dissertations

Tablets are the most popular solid dosage form in the pharmaceutical industry because they are cheap to manufacture, chemically and mechanically stable and easy to transport and fairly easy to control dosage. Pharmaceutical tableting operations have been around for decades however the process is still not well understood. One of the common problems faced during the production of pharmaceutical tablets by powder compaction is sticking of powder to the punch face, This is known as 'sticking'. A more specialized case of sticking is picking when the powder is pulled away form the compact in the vicinity of debossed features. In …


Universal Weight Machine, Oscar Andrade, Bibiana Koch, Robert Molloy, Haley Rentfro, Emily Woods Jun 2016

Universal Weight Machine, Oscar Andrade, Bibiana Koch, Robert Molloy, Haley Rentfro, Emily Woods

Mechanical Engineering

The purpose of this project is to design and build an inexpensive, universally accessible multi-station exercise machine for the physical and mental well-being of athletes of the Special Olympics and Pathpoint Life Education & Advancement Program. The machine has three sides tiered to higher resistance: the first station offers a minimal resistance aerobic exercise focused on moving the arms with an ergometer, the second station provides numerous locations to latch on resistance bands that will build strength in the athlete’s arms and chest, and the final station has a donated weight machine that offers lat pulldowns and flys with maximum …


Portable Sensory Room For The West Orange County Consortium For Special Education, Lindsey Chase, Emma Eskildsen, Alex Fox, Claire Francis, Nate Hoffman, Kaylee Keck, Sarah Sullivan Jun 2016

Portable Sensory Room For The West Orange County Consortium For Special Education, Lindsey Chase, Emma Eskildsen, Alex Fox, Claire Francis, Nate Hoffman, Kaylee Keck, Sarah Sullivan

Biomedical Engineering

This report discusses the development of a Portable Sensory Room to be used at Newland Elementary School in Huntington Beach. Newland Elementary has an exceptional Special Needs program that teaches the children with the most severe cases of autism in its school district. People with autism typically also have sensory processing disorders, which can be extremely disruptive for a child’s development and can make it difficult for a child to be able to concentrate long enough to gain necessary life skills. The idea behind a Sensory Rooms is to create a place to calm the students and to expose them …


Improving Ventricular Catheter Design Through Computational Fluid Dynamics, Sofy Hefets Weisenberg May 2016

Improving Ventricular Catheter Design Through Computational Fluid Dynamics, Sofy Hefets Weisenberg

Masters Theses

Cerebrospinal fluid (CSF) shunts are fully implantable medical devices that are used to treat patients suffering from conditions characterized by elevated intracranial pressure, such as hydrocephalus. In cases of shunt failure or malfunction, patients are often required to endure one or more revision surgeries to replace all or part of the shunt. One of the primary causes of CSF shunt failure is obstruction of the ventricular catheter, a component of the shunt system implanted directly into the brain's ventricular system. This work aims to improve the design of ventricular catheters in order to reduce the incidence of catheter obstruction and …


Coding Strategies For Cochlear Implants Under Adverse Environments, Qudsia Tahmina May 2016

Coding Strategies For Cochlear Implants Under Adverse Environments, Qudsia Tahmina

Theses and Dissertations

Cochlear implants are electronic prosthetic devices that restores partial hearing in patients with severe to profound hearing loss. Although most coding strategies have significantly improved the perception of speech in quite listening conditions, there remains limitations on speech perception under adverse environments such as in background noise, reverberation and band-limited channels, and we propose strategies that improve the intelligibility of speech transmitted over the telephone networks, reverberated speech and speech in the presence of background noise. For telephone processed speech, we propose to examine the effects of adding low-frequency and high- frequency information to the band-limited telephone speech. Four listening …


Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch Apr 2016

Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

This thesis presents the design, controls, and testing of two systems: a novel colonoscope locomotion design for diagnostics, and a biosensor capsule that implants a sensor in the small intestine. Each system requires special design considerations for use in the gastrointestinal system.

Colonoscopy procedures are recommended as a screening for colon cancer and related conditions after the age of 50. The need for an improved colonoscope that reduces the colonoscopy time and patient discomfort is apparent. The semi-autonomous device presented here could likely reduce the colonoscopy procedure time by allowing the physician to focus more on the diagnosis and less …


Optimizing The Rehabilitation Of Elbow Lateral Collateral Ligament Injuries, Ranita Harpreet Kaur Manocha Mar 2016

Optimizing The Rehabilitation Of Elbow Lateral Collateral Ligament Injuries, Ranita Harpreet Kaur Manocha

Electronic Thesis and Dissertation Repository

Elbow lateral collateral ligament (LCL) injuries frequently arise following trauma, and can result in disabling instability. Typically such injuries are managed with immobilization followed by a graduated exercise regime; however there is minimal biomechanical evidence to support current treatment protocols. This investigation examines the in vitro effectiveness of several rehabilitation techniques using a custom elbow motion simulator. It was found that active range of motion is safest in the overhead position (n = 7). Early motion in this position may reduce the incidence of elbow stiffness without compromising ligament healing following LCL injury. Forearm pronation and active motion stabilize …


Biventricular Finite Element Modeling And Quantification Of 3d Langragian Strains And Torsion Using Dense Mri, Zhanqiu Liu Jan 2016

Biventricular Finite Element Modeling And Quantification Of 3d Langragian Strains And Torsion Using Dense Mri, Zhanqiu Liu

Theses and Dissertations--Mechanical Engineering

Statistical data suggests that increased use of evidence-based medical therapies has largely contributed to the decrease in American death rate caused by heart disease. And my studies are about two applications of magnetic resonance imaging (MRI) as a non-invasive approach in evidence-based health care research. In my first study, the achievement of a pulmonary valve replacement surgery was assessed on a patient with tetralogy of Fallot (TOF). In order to evaluate the remodeling of right ventricle, two biventricular finite element models were built up for pre-surgical images and post-surgical images. In my second study, 3D Lagrangian strains and torsion in …


Active Stiffening Of F-Actin Network Dominated By Structural Transition Of Actin Filaments Into Bundles, Shengmao Lin, Xinwei Han, Gary C.P. Tsui, David Hui, Linxia Gu Jan 2016

Active Stiffening Of F-Actin Network Dominated By Structural Transition Of Actin Filaments Into Bundles, Shengmao Lin, Xinwei Han, Gary C.P. Tsui, David Hui, Linxia Gu

Department of Mechanical and Materials Engineering: Faculty Publications

Molecular motor regulated active contractile force is key for cells sensing and responding to their mechanical environment, which leads to characteristic structures and functions of cells. The F-actin network demonstrates a two-order of magnitude increase in its modulus due to contractility; however, the mechanism for this active stiffening remains unclear. Two widely acknowledged hypotheses are that active stiffening of F-actin network is caused by (1) the nonlinear force-extension behavior of cross-linkers, and (2) the loading mode being switched from bending to stretching dominated regime. Direct evidence supporting either theory is lacking. Here we examined these hypotheses and showed that a …


Design And Commissioning Of A Community Scale Solar Powered Membrane-Based Water Purification System In Haiti, Shavin Pinto, Yung Wong, Kyle Fennesy, Yan Tang, Marc Compere Jan 2016

Design And Commissioning Of A Community Scale Solar Powered Membrane-Based Water Purification System In Haiti, Shavin Pinto, Yung Wong, Kyle Fennesy, Yan Tang, Marc Compere

Publications

This paper presents the design and commissioning of a solar powered water purification system at the Ryan Epps Home for Children (REHC) in Michaud, Haiti. This system supplies clean drinking water to the 200 children who live and go to school at REHC and also to the community in the form of a micro-business. This micro-business is the mechanism for income generation for sustainable system operation. The purifier uses a three stage filtration system with a disc-type sediment filter, a 0.1 micron ultrafiltration membrane, and an ultraviolet light for disinfection. The backwash cycle extends the life of the ultrafiltration membrane …


In-Shoe Plantar Pressure System To Investigate Ground Reaction Force Using Android Platform, Ahmed A. Mostfa Jan 2016

In-Shoe Plantar Pressure System To Investigate Ground Reaction Force Using Android Platform, Ahmed A. Mostfa

Theses and Dissertations

Human footwear is not yet designed to optimally relieve pressure on the heel of the foot. Proper foot pressure assessment requires personal training and measurements by specialized machinery. This research aims to investigate and hypothesize about Preferred Transition Speed (PTS) and to classify the gait phase of explicit variances in walking patterns between different subjects. An in-shoe wearable pressure system using Android application was developed to investigate walking patterns and collect data on Activities of Daily Living (ADL). In-shoe circuitry used Flexi-Force A201 sensors placed at three major areas: heel contact, 1st metatarsal, and 5th metatarsal with a PIC16F688 microcontroller …