Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 8 of 8

Full-Text Articles in Bioimaging and Biomedical Optics

Objectively Measuring Effects Of Electro-Acupuncture In Parkinsonian Rhesus Monkeys, Rui Zhang, Anders H. Andersen, Peter A. Hardy, Eric Forman, April Evans, Yi Ai, Jin Yue, Guihua Yue, Don M. Gash, Richard Grondin, Zhiming Zhang Jan 2018

Objectively Measuring Effects Of Electro-Acupuncture In Parkinsonian Rhesus Monkeys, Rui Zhang, Anders H. Andersen, Peter A. Hardy, Eric Forman, April Evans, Yi Ai, Jin Yue, Guihua Yue, Don M. Gash, Richard Grondin, Zhiming Zhang

Magnetic Resonance Imaging and Spectroscopy Center Faculty Publications

Acupuncture has increasingly been used as an alternative therapy for treatment of Parkinson’s disease (PD). However, the efficacy of acupunture for PD still remains unclear. The present study was designed to objectively and safely monitor anti-parkinsonian effects of electroacupuncture (EA) and brain activity in nonhuman primates modeling human PD. Six middle-aged rhesus monkeys were extensively studied by a computerized behavioral testing battery and by pharmacological MRI (phMRI) scans with specific dopaminergic drug stimulations. All animals were evaluated for behavior and phMRI responses under normal, parkinsonian, parkinsonian with EA treatment and parkinsonian after EA treatment conditions. Stable parkinsonian features were observed …


High Resolution Imaging Of The Mitral Valve In The Natural State With 7 Tesla Mri, Sam E. Stephens, Serguei Liachenko, Neil B. Ingels, Jonathan F. Wenk, Morten O. Jensen Aug 2017

High Resolution Imaging Of The Mitral Valve In The Natural State With 7 Tesla Mri, Sam E. Stephens, Serguei Liachenko, Neil B. Ingels, Jonathan F. Wenk, Morten O. Jensen

Mechanical Engineering Faculty Publications

Imaging techniques of the mitral valve have improved tremendously during the last decade, but challenges persist. The delicate changes in annulus shape and papillary muscle position throughout the cardiac cycle have significant impact on the stress distribution in the leaflets and chords, thus preservation of anatomically accurate positioning is critical. The aim of this study was to develop an in vitro method and apparatus for obtaining high-resolution 3D MRI images of porcine mitral valves in both the diastolic and systolic configurations with physiologically appropriate annular shape, papillary muscle positions and orientations, specific to the heart from which the valve was …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


Quantitative, Spectrally-Resolved Intraoperative Fluorescence Imaging, Pablo A. Valdés, Frederic Leblond, Valerie L. Jacobs, Brian C. Wilson, Keith D. Paulsen, David W. Roberts Nov 2012

Quantitative, Spectrally-Resolved Intraoperative Fluorescence Imaging, Pablo A. Valdés, Frederic Leblond, Valerie L. Jacobs, Brian C. Wilson, Keith D. Paulsen, David W. Roberts

Dartmouth Scholarship

Intraoperative visual fluorescence imaging (vFI) has emerged as a promising aid to surgical guidance, but does not fully exploit the potential of the fluorescent agents that are currently available. Here, we introduce a quantitative fluorescence imaging (qFI) approach that converts spectrally-resolved data into images of absolute fluorophore concentration pixel-by-pixel across the surgical field of view (FOV). The resulting estimates are linear, accurate, and precise relative to true values, and spectral decomposition of multiple fluorophores is also achieved. Experiments with protoporphyrin IX in a glioma rodent model demonstrate in vivo quantitative and spectrally-resolved fluorescence imaging of infiltrating tumor margins for the …


Resting-State Connectivity Identifies Distinct Functional Networks In Macaque Cingulate Cortex., R Matthew Hutchison, Thilo Womelsdorf, Joseph S Gati, L Stan Leung, Ravi S Menon, Stefan Everling Jun 2012

Resting-State Connectivity Identifies Distinct Functional Networks In Macaque Cingulate Cortex., R Matthew Hutchison, Thilo Womelsdorf, Joseph S Gati, L Stan Leung, Ravi S Menon, Stefan Everling

Physiology and Pharmacology Publications

Subregions of the cingulate cortex represent prominent intersections in the structural networks of the primate brain. The relevance of the cingulate to the structure and dynamics of large-scale networks ultimately requires a link to functional connectivity. Here, we map fine-grained functional connectivity across the complete extent of the macaque (Macaca fascicularis) cingulate cortex and delineate subdivisions pertaining to distinct identifiable networks. In particular, we identified 4 primary networks representing the functional spectrum of the cingulate: somatomotor, attention-orienting, executive, and limbic. The cingulate nodes of these networks originated from separable subfields along the rostral-to-caudal axis and were characterized by positive and …


Quantitative Cherenkov Emission Spectroscopy For Tissue Oxygenation Assessment, Johan Axelsson, Adam K. Glaser, David J. Gladstone, Brian W. Pogue Feb 2012

Quantitative Cherenkov Emission Spectroscopy For Tissue Oxygenation Assessment, Johan Axelsson, Adam K. Glaser, David J. Gladstone, Brian W. Pogue

Dartmouth Scholarship

Measurements of Cherenkov emission in tissue during radiation therapy are shown to enable estimation of hemoglobin oxygen saturation non-invasively, through spectral fitting of the spontaneous emissions from the treated tissue. Tissue oxygenation plays a critical role in the efficacy of radiation therapy to kill tumor tissue. Yet in-vivo measurement of this has remained elusive in routine use because of the complexity of oxygen measurement techniques. There is a spectrally broad emission of Cherenkov light that is induced during the time of irradiation, and as this travels through tissue from the point of the radiation deposition, the tissue absorption and scatter …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jan 2007

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Edward Yu

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …