Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

2018

California Polytechnic State University, San Luis Obispo

Discipline
Keyword
Publication
Publication Type

Articles 1 - 25 of 25

Full-Text Articles in Biomedical Engineering and Bioengineering

Wireless Ekg, James Kerman, Chin Chao, Galen Wu, Eric Burstedt Dec 2018

Wireless Ekg, James Kerman, Chin Chao, Galen Wu, Eric Burstedt

Mechanical Engineering

In 2016, Dr. Ahmad Nooristani identified a need for a personal EKG that is cheaper and simpler than hospital grade systems, but more accurate than personal devices currently on the market. Two previous teams did significant background research, prototyping, focusing on ease of use, portability, and physical specifications. However, neither team was able to produce a device with electrodes that could successfully collect an EKG signal and transmit it to a phone or tablet, one of the main requirements from the Dr. Nooristani. This team focused on designing a six lead, five electrode EKG device to transmit EKG data from …


Hip And Knee Biomechanics For Transtibial Amputees In Gait, Cycling, And Elliptical Training, Greg Orekhov Dec 2018

Hip And Knee Biomechanics For Transtibial Amputees In Gait, Cycling, And Elliptical Training, Greg Orekhov

Master's Theses

Transtibial amputees are at increased risk of contralateral hip and knee joint osteoarthritis, likely due to abnormal biomechanics. Biomechanical challenges exist for transtibial amputees in gait and cycling; particularly, asymmetry in ground/pedal reaction forces and joint kinetics is well documented and state-of-the-art passive and powered prostheses do not fully restore natural biomechanics. Elliptical training has not been studied as a potential exercise for rehabilitation, nor have any studies been published that compare joint kinematics and kinetics and ground/pedal reaction forces for the same group of transtibial amputees in gait, cycling, and elliptical training. The hypothesis was that hip and knee …


In Vitro Growth Of Osteoblasts On Poly Lactic-Co-Glycolic Acid Scaffolds Created Via Gas Foaming, Matthew James Thomas Sep 2018

In Vitro Growth Of Osteoblasts On Poly Lactic-Co-Glycolic Acid Scaffolds Created Via Gas Foaming, Matthew James Thomas

Master's Theses

This study analyzed the feasibility of using gas foaming to create Poly Lactic-co-Glycolic Acid (PLGA) scaffolds for use as a substrate in bone tissue engineering and set out to determine whether the presence of osteoblasts on these scaffolds enhanced their material stiffness. The process of bone formation involves osteoblasts depositing extracellular matrix and calcifying this matrix with calcium phosphate crystals (Hasegawa et al., 2017) and pits between 30-40μm in diameter on tissue engineering scaffold surfaces have been shown to best promote osteogenic activity in the presence of bone-forming cells (Halai et al., 2014).The scaffolds were determined to contain pits within …


Microfluidic Electrical Impedance Spectroscopy, John J. Foley Sep 2018

Microfluidic Electrical Impedance Spectroscopy, John J. Foley

Master's Theses

The goal of this study is to design and manufacture a microfluidic device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured ethanol impedance initially to show that values remain consistent over time. Impedance values of water and 1% wt. saltwater were compared to show that the device is able to detect changes in impedance, with up to a 60% reduction in electrical impedance in saltwater. Cells were …


Inverse Dynamic Analysis Of Acl Reconstructed Knee Joint Biomechanics During Gait And Cycling Using Opensim, Megan V. Pottinger Aug 2018

Inverse Dynamic Analysis Of Acl Reconstructed Knee Joint Biomechanics During Gait And Cycling Using Opensim, Megan V. Pottinger

Master's Theses

ACL (anterior cruciate ligament) injuries of the knee joint alter biomechanics and may cause abnormal loading conditions that place patients at a higher risk of developing osteoarthritis (OA). There are multiple types of ACL reconstruction (ACLR), but all types aim to restore anterior tibial translation and internal tibial rotation following surgery. Analyzing knee joint contact loads provide insight into the loading conditions following ACLR that may contribute to the long-term development of OA. Ten ACLR subjects, who underwent the same reconstruction, performed gait and cycling experiments while kinematic and kinetic data were collected. Inverse dynamic analyses were performed on processed …


Multi-Purpose Heart Valve Therapy Assembly Fixture, Alec John Foster, John Patrick Hofstetter, Emily Lim Jun 2018

Multi-Purpose Heart Valve Therapy Assembly Fixture, Alec John Foster, John Patrick Hofstetter, Emily Lim

Mechanical Engineering

STATEMENT OF CONFIDENTIALITY: The complete senior project report was submitted to the project advisor and sponsors. The results of this project are of a confidential nature and will not be published at this time.


Identification System For Heart Valve Manufacturing, Nicholas Robert Jensen, Edgar Davis Nix, Judith Evelyn Gonzalez, Albert Austin Liddicoat Jun 2018

Identification System For Heart Valve Manufacturing, Nicholas Robert Jensen, Edgar Davis Nix, Judith Evelyn Gonzalez, Albert Austin Liddicoat

Mechanical Engineering

Abstract withheld due to NDA constraints


Foot Stress And Blood Flow Sensing Under High-Loading During Hip Surgery, Chris Cardenas, Esther Chen, Claire Kingston, Katie Paswaters, Brianna Rodebaugh Jun 2018

Foot Stress And Blood Flow Sensing Under High-Loading During Hip Surgery, Chris Cardenas, Esther Chen, Claire Kingston, Katie Paswaters, Brianna Rodebaugh

Mechanical Engineering

The PolyHIPS team was tasked with integrating sensors into Stryker’s hip arthroscopy boot that monitor blood flow and heel slip during hip surgery. During hip arthroscopy, the femur head is distracted from the acetabulum to create space in the joint for the surgeon to operate. This requires the use of up to 200 lbf. In order to maintain this space, the foot is held tightly in the boot. Complications can result from the foot being held too tightly in the boot during the procedure. The most common complication is neuropraxia, or temporary nerve damage. PolyHIPS proposes a solution that utilizes …


Fixing Vertebral Compression Fractures With Medtronic, Kelly Fitzgerald, Trevor Bingham, Alex Denbaugh, Jordan Tang, Jon Stearns Jun 2018

Fixing Vertebral Compression Fractures With Medtronic, Kelly Fitzgerald, Trevor Bingham, Alex Denbaugh, Jordan Tang, Jon Stearns

Industrial and Manufacturing Engineering

No abstract provided.


Analysis Of The Low-Cycle Fatigue Behavior Of Silicone Rubber For Biomedical Balloons, Chase Cooper Jun 2018

Analysis Of The Low-Cycle Fatigue Behavior Of Silicone Rubber For Biomedical Balloons, Chase Cooper

Materials Engineering

The development of a medical drug delivery device that allows for the deployment drugs into the adventitial tissue of blood vessels requires the inflation of a silicone elastomer. The inflated silicone must be able to consistently endure multiple loading cycles without failing so that the device can operate reliably. There are multiple methods of processing the silicone for the device and the goal of this study is to examine the effect of the various processing methods on the characteristics of the silicone. The Dynamic Mechanical Analysis Machine (DMA) is used to model the conditions of the device’s application by performing …


Transcatheter Heart Valve Leaflet Assembly Tooling Improvement Final Design Report, James Craig Sherman, Zachary Robert Dicks, Luke Edward Williams Jun 2018

Transcatheter Heart Valve Leaflet Assembly Tooling Improvement Final Design Report, James Craig Sherman, Zachary Robert Dicks, Luke Edward Williams

Mechanical Engineering

Statement of Confidentiality: The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


Annuloplasty Mti: Improved Tooling For Annuloplasty Ring Manufacturing, Justin David Smith, Spencer Lee Combs, Luke Edward Maly Jun 2018

Annuloplasty Mti: Improved Tooling For Annuloplasty Ring Manufacturing, Justin David Smith, Spencer Lee Combs, Luke Edward Maly

Mechanical Engineering

The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


Dynamic Model For Simulating Motion Of The Right Ventricle, Brian Michael Larsen, Sam Koopman Porter, John Francis D'Ambrosio Jun 2018

Dynamic Model For Simulating Motion Of The Right Ventricle, Brian Michael Larsen, Sam Koopman Porter, John Francis D'Ambrosio

Mechanical Engineering

This report documents all the research, ideation, and mockups used to determine right ventricle motion and develop a system capable of reproducing that motion on a tissue sample. The model is intended for evaluating anchoring systems being developed by Edwards Lifesciences for use with tricuspid valve therapies. Several design solutions were considered for the primary functions of recreating motion of the right ventricle and attaching tissue to the device. From these ideas a primary means of producing motion and attaching tissue was selected. These ideas were then developed over the course of a school year to become the final system …


Characterization Of Arterial Flow For Junctional Bleeding Control, Nick Bosio Jun 2018

Characterization Of Arterial Flow For Junctional Bleeding Control, Nick Bosio

Master's Theses

This study investigated reducing volumetric flowrate under steady flow conditions by varying lengths of compression with constant cross-sectional area and varying cross-sectional area reduction with constant length in order to better understand how to control junctional hemorrhaging. The hypotheses of this study were that length reduction will have little effect on volumetric flowrate and that cross-sectional area reduction would need to be approximately 80 percent in order to obtain bleeding control. The study found that length reduction has little effect on changing the flowrate. However, in order to obtain at least 80 percent reduction in flow, the area needs to …


Detection Method Of Subclinical Atherosclerosis Of The Carotid Artery With A Hemodynamics Modeling Approach, Marisa Peressini Jun 2018

Detection Method Of Subclinical Atherosclerosis Of The Carotid Artery With A Hemodynamics Modeling Approach, Marisa Peressini

Master's Theses

Subclinical atherosclerosis is an important area of research to evaluate stroke risk and predict localization of plaque. The current methods for detecting atherosclerosis risk are insufficient because it is based on The Framingham Risk Score and carotid intima media thickness, therefore an engineering detection model based on quantifiable data is needed. Laminar and turbulent flow, dictated by Reynolds number and relative roughness, was modeled through the carotid artery bifurcation to compare shear stress and shear rate. Computer-aided design and fluid flow software were used to model hemodynamics through the carotid artery. Data from the model was derived from governing equations …


Extended-Use Ecg Monitor, Daniel Aaron Soski Jun 2018

Extended-Use Ecg Monitor, Daniel Aaron Soski

Master's Theses

In this thesis, a prototype ECG monitor was developed that is integrated into an elastic shirt and takes a 3-lead ECG for over 5 days. The high-quality measurements can be used to identify markers indicative of various detrimental heart conditions. Measurements recorded by the device are encrypted and stored onto a micro-SD card. Current Holter monitors are expensive and have functional lives less than 48 hours; however, extended duration monitoring has been proven more useful in diagnosis. The device designed demonstrates that ECG measurements can be taken over longer durations without sacrificing quality, comfort, or device cost.


Assessing The Photoprotective Effects Of Fluorescent Sphingomyelin Against Uvb Induced Dna Damage In Human Keratinocytes, Rebecca Marie Kandell Jun 2018

Assessing The Photoprotective Effects Of Fluorescent Sphingomyelin Against Uvb Induced Dna Damage In Human Keratinocytes, Rebecca Marie Kandell

Master's Theses

Non Melanoma Skin Cancer (NMSC) affects 3.3 million Americans each year and results from Ultra Violet Radiation (UVR) damage to DNA in the form of pyrimidine dimers and photoproducts [1]–[5]. Cells directly detect the damage and initiate apoptosis, cell cycle arrest, or DNA repair by modulating p53 and p21 levels [6]–[9]. Current methods of photoprotection include sunscreen, but controversy over safety of some active ingredients necessitates research into more natural alternatives [10]–[12]. In particular, 24 hour incubation with bovine milk sphingomyelin (BSM) has demonstrated photoprotective potential by reducing p21 and p53 levels in keratinocytes (KRTs) after UV radiation [13], [14]. …


Preparation Of Supramolecular Amphiphilic Cyclodextrin Bilayer Vesicles For Pharmaceutical Applications, Kate E. Frischkorn Jun 2018

Preparation Of Supramolecular Amphiphilic Cyclodextrin Bilayer Vesicles For Pharmaceutical Applications, Kate E. Frischkorn

Master's Theses

Recent pharmaceutical developments have investigated using supramolecular nanoparticles in order to increase the bioavailability and solubility of drugs delivered in various methods. Modification of the carbohydrate cyclodextrin increases the ability to encapsulate hydrophobic pharmaceutical molecules by forming a carrier with a hydrophobic core and hydrophilic exterior. Guest molecules are commonly added to these inclusion complexes in order to add stability and further increase targeting abilities of the carriers. One such guest molecule is adamantine combined with a poly(ethylene glycol) chain. Vesicles are formed by hydrating a thin film of amphiphilic cyclodextrin and guest molecules in buffer solution that mimics physiological …


Comparative Analysis Of Physiological Measurements And Environmental Metrics On Predicting Heat Stress Related Events, Mckenzie Lee Barlow Jun 2018

Comparative Analysis Of Physiological Measurements And Environmental Metrics On Predicting Heat Stress Related Events, Mckenzie Lee Barlow

Master's Theses

Exposure to high heat and humidity can lead to serious health risks, including heat exhaustion and heat stroke. Wet Bulb Globe Temperature (WBGT) and heat index have historically been used to predict heat stress events, but individualized factors are not included in the measurement. It has been shown that there is a relationship between cardiovascular measurements and heat stress, which could be used to measure heat stress risk on an individual level. Research has been done to find relationships between cardiovascular metrics in a workplace environment, however the study did not include the use of a controlled environment as a …


Neuro-Silicon Interface Of A Hirudo Medicinalis Retzius Cell Integrated With Field Effect Transistor, Kurt Christian Sjoberg Jun 2018

Neuro-Silicon Interface Of A Hirudo Medicinalis Retzius Cell Integrated With Field Effect Transistor, Kurt Christian Sjoberg

Master's Theses

The focus of this thesis was to measure the intracellular voltage of a living neural cell using a silicon transistor. The coupling of neurological tissues with silicon devices is of interest to the fields of neurology, neuroscience, electrophysiology and cellular biology. In previous work by Peter Fromherz, single neurons were successfully coupled to transistors [1]. This thesis aims to show proof of concept of the fabrication of a simple neuro-silicon interface using wafer processing methods currently available at Cal Poly. The types of transistors and cells used, the methods for dissecting and preparing the cells, the electrophysiology methods for validating …


Validation Of A 1d Algorithm That Measures Pulse Wave Velocity To Estimate Compliance In Blood Vessels, James Leung Jun 2018

Validation Of A 1d Algorithm That Measures Pulse Wave Velocity To Estimate Compliance In Blood Vessels, James Leung

Master's Theses

The purpose of this research is to determine if it is possible to validate the new 1D method for measuring pulse wave velocity in the aorta in vivo and estimate compliance. Arterial pressure and blood flow characterize the traveling of blood from the heart to the arterial system and have played a significant role in the evaluation of cardiovascular diseases. Blood vessel distensibility can give some information on the evolution of cardiovascular disease. A patient’s aorta cannot be explanted to measure compliance; therefore we are using a flow phantom model to validate the 1D pulse wave velocity technique to estimate …


Effects Of Game Pitch Count And Body Mass Index On Pitching Biomechanics In 9-To 10-Year-Old Baseball Athletes, Jim D. Darke, Eshan M. Dandekar, Arnel L. Aguinaldo, Scott J. Hazelwood, Stephen M. Klisch Apr 2018

Effects Of Game Pitch Count And Body Mass Index On Pitching Biomechanics In 9-To 10-Year-Old Baseball Athletes, Jim D. Darke, Eshan M. Dandekar, Arnel L. Aguinaldo, Scott J. Hazelwood, Stephen M. Klisch

Biomedical Engineering

Background: Pitching while fatigued and body composition may increase the injury risk in youth and adult pitchers. However, the relationships between game pitch count, biomechanics, and body composition have not been reported for a study group restricted to 9-to 10-year-old athletes.

Hypothesis: During a simulated game with 9-to 10-year-old athletes, (1) participants will experience biomechanical signs of fatigue, and (2) shoulder and elbow kinetics will correlate with body mass index (BMI).

Study Design: Descriptive laboratory study. Methods: Thirteen 9-to 10-year-old youth baseball players pitched a simulated game (75 pitches). Range of motion and muscular output tests were conducted before and …


Effects Of Game Pitch Count And Body Mass Index On Pitching Biomechanics In 9- To 10-Year-Old Baseball Athletes, Scott Hazelwood, Jim D. Darke, Eshan M. Dandekar, Arnel L. Aguinaldo, Stephen M. Klisch Apr 2018

Effects Of Game Pitch Count And Body Mass Index On Pitching Biomechanics In 9- To 10-Year-Old Baseball Athletes, Scott Hazelwood, Jim D. Darke, Eshan M. Dandekar, Arnel L. Aguinaldo, Stephen M. Klisch

Biomedical Engineering

Background:

Pitching while fatigued and body composition may increase the injury risk in youth and adult pitchers. However, the relationships between game pitch count, biomechanics, and body composition have not been reported for a study group restricted to 9- to 10-year-old athletes.

Hypothesis:

During a simulated game with 9- to 10-year-old athletes, (1) participants will experience biomechanical signs of fatigue, and (2) shoulder and elbow kinetics will correlate with body mass index (BMI).

Study Design:

Descriptive laboratory study.

Methods:

Thirteen 9- to 10-year-old youth baseball players pitched a simulated game (75 pitches). Range of motion and …


Virtual Stethoscope/Otoscope Duo, Camila P. Monchini, Paige R. Mazur, Christian Navarro Mar 2018

Virtual Stethoscope/Otoscope Duo, Camila P. Monchini, Paige R. Mazur, Christian Navarro

Biomedical Engineering

The virtual stethoscope/otoscope duo is a medical device intended to allow patients to be seen by their medical provider via internet consultations from the comfort of their own home. This device allows patients to substitute in-person doctor visits by checking a patient’s cardiovascular, respiratory, and auditory health. This document is the statement of work for the virtual stethoscope/otoscope duo and contains information on similar products, patents, and relevant literatures containing virtual technologies that assist in patient diagnosis. Product specifications and other details for the device such as performance evaluation review techniques can also be found within this document outlining the …


Preparation For The Study Of Gene Expression Aboard The International Space Station, Amber Paturzo Jan 2018

Preparation For The Study Of Gene Expression Aboard The International Space Station, Amber Paturzo

STAR Program Research Presentations

WetLab-2 performs quantitative polymerase chain reaction (qPCR) aboard the micro-gravity environment of the International Space Station in order to research how the stress of micro-gravity affects an organism’s RNA production and gene expression. This on-station qPCR allows researchers to gather information earlier and thereby allow them to modify experiments in a matter of hours rather than wait until the next flight opportunity. After a successful validation flight on SpaceX-8 and follow-up investigation on SpaceX-9, system components must now be adjusted for a new type of biological sample. Specifically, the WetLab-2 facility includes a commercial qPCR instrument (RNA SmartCycler), a sample …