Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Biomedical Engineering and Bioengineering

White Matter Hyperintensity Associations With Cerebral Blood Flow In Elderly Subjects Stratified By Cerebrovascular Risk, Ahmed A. Bahrani, David K. Powell, Guoqiang Yu, Eleanor S. Johnson, Gregory A. Jicha, Charles D. Smith Apr 2017

White Matter Hyperintensity Associations With Cerebral Blood Flow In Elderly Subjects Stratified By Cerebrovascular Risk, Ahmed A. Bahrani, David K. Powell, Guoqiang Yu, Eleanor S. Johnson, Gregory A. Jicha, Charles D. Smith

Biomedical Engineering Faculty Publications

Objective: This study aims to add clarity to the relationship between deep and periventricular brain white matter hyperintensities (WMHs), cerebral blood flow (CBF), and cerebrovascular risk in older persons. Methods: Deep white matter hyperintensity (dWMH) and periventricular white matter hyperintensity (pWMH) and regional gray matter (GM) and white matter (WM) blood flow from arterial spin labeling were quantified from magnetic resonance imaging scans of 26 cognitively normal elderly subjects stratified by cerebrovascular disease (CVD) risk. Fluidattenuated inversion recovery images were acquired using a high-resolution 3-dimensional (3-D) sequence that reduced partial volume effects seen with slicebased techniques. Results: dWMHs but not …


Using A Respiratory Navigator Significantly Reduces Variability When Quantifying Left Ventricular Torsion With Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Kristin N. Andres, David K. Powell, Richard J. Charnigo, Brandon K. Fornwalt Mar 2017

Using A Respiratory Navigator Significantly Reduces Variability When Quantifying Left Ventricular Torsion With Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Kristin N. Andres, David K. Powell, Richard J. Charnigo, Brandon K. Fornwalt

Electrical and Computer Engineering Faculty Publications

Background: Left ventricular (LV) torsion is an important indicator of cardiac function that is limited by high inter-test variability (50% of the mean value). We hypothesized that this high inter-test variability is partly due to inconsistent breath-hold positions during serial image acquisitions, which could be significantly improved by using a respiratory navigator for cardiovascular magnetic resonance (CMR) based quantification of LV torsion.

Methods: We assessed respiratory-related variability in measured LV torsion with two distinct experimental protocols. First, 17 volunteers were recruited for CMR with cine displacement encoding with stimulated echoes (DENSE) in which a respiratory navigator was used to measure …


Timing And Magnitude Of Lumbar Spine Contribution To Trunk Forward Bending And Backward Return In Patients With Acute Low Back Pain, Iman Shojaei, Milad Vazirian, Elizabeth G. Salt, Linda R. Van Dillen, Babak Bazrgari Feb 2017

Timing And Magnitude Of Lumbar Spine Contribution To Trunk Forward Bending And Backward Return In Patients With Acute Low Back Pain, Iman Shojaei, Milad Vazirian, Elizabeth G. Salt, Linda R. Van Dillen, Babak Bazrgari

Biomedical Engineering Faculty Publications

Alterations in the lumbo-pelvic coordination denote changes in neuromuscular control of trunk motion as well as load sharing between passive and active tissues in the lower back. Differences in timing and magnitude aspects of lumbo-pelvic coordination between patients with chronic low back pain (LBP) and asymptomatic individuals have been reported; yet, the literature on lumbo-pelvic coordination in patients with acute LBP is scant. A case-control study was conducted to explore the differences in timing and magnitude aspects of lumbo-pelvic coordination between females with (n=19) and without (n=19) acute LBP. Participants in each group completed one experimental session wherein they performed …


Comparison Of Lumbo-Pelvic Kinematics During Trunk Forward Bending And Backward Return Between Patients With Acute Low Back Pain And Asymptomatic Controls, Iman Shojaei, Elizabeth G. Salt, Quenten L. Hooker, Linda R. Van Dillen, Babak Bazrgari Jan 2017

Comparison Of Lumbo-Pelvic Kinematics During Trunk Forward Bending And Backward Return Between Patients With Acute Low Back Pain And Asymptomatic Controls, Iman Shojaei, Elizabeth G. Salt, Quenten L. Hooker, Linda R. Van Dillen, Babak Bazrgari

Biomedical Engineering Faculty Publications

Background—Prior studies have reported differences in lumbo-pelvic kinematics during a trunk forward bending and backward return task between individuals with and without chronic low back pain; yet, the literature on lumbo-pelvic kinematics of patients with acute low back pain is scant. Therefore, the purpose of this study was set to investigate lumbo-pelvic kinematics in this cohort.

Methods—A case-control study was conducted to investigate the differences in pelvic and thoracic rotation along with lumbar flexion as well as their first and second time derivatives between females with and without acute low back pain. Participants in each group completed one …


Antibody-Nanoparticle Conjugates To Enhance The Sensitivity Of Elisa-Based Detection Methods., Margaret M Billingsley, Rachel S. Riley, Emily S Day Jan 2017

Antibody-Nanoparticle Conjugates To Enhance The Sensitivity Of Elisa-Based Detection Methods., Margaret M Billingsley, Rachel S. Riley, Emily S Day

Henry M. Rowan College of Engineering Faculty Scholarship

Accurate antigen detection is imperative for clinicians to diagnose disease, assess treatment success, and predict patient prognosis. The most common technique used for the detection of disease-associated biomarkers is the enzyme linked immunosorbent assay (ELISA). In an ELISA, primary antibodies are incubated with biological samples containing the biomarker of interest. Then, detectible secondary antibodies conjugated with horseradish peroxidase (HRP) bind the primary antibodies. Upon addition of a color-changing substrate, the samples provide a colorimetric signal that directly correlates to the targeted biomarker concentration. While ELISAs are effective for analyzing samples with high biomarker content, they lack the sensitivity required to …