Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

2013

Electrical and Computer Engineering

Theses/Dissertations

Articles 1 - 13 of 13

Full-Text Articles in Biomedical Engineering and Bioengineering

Under-Sampled Reconstruction Techniques For Accelerated Magnetic Resonance Imaging, Mohammad H. Kayvanrad Dec 2013

Under-Sampled Reconstruction Techniques For Accelerated Magnetic Resonance Imaging, Mohammad H. Kayvanrad

Electronic Thesis and Dissertation Repository

Due to physical and biological constraints and requirements on the minimum resolution and SNR, the acquisition time is relatively long in magnetic resonance imaging (MRI). Consequently, a limited number of pulse sequences can be run in a clinical MRI session because of constraints on the total acquisition time due to patient comfort and cost considerations. Therefore, it is strongly desired to reduce the acquisition time without compromising the reconstruction quality. This thesis concerns under-sampled reconstruction techniques for acceleration of MRI acquisitions, i.e., parallel imaging and compressed sensing.

While compressed sensing MRI reconstructions are commonly regularized by penalizing the decimated wavelet …


Analysis, Segmentation And Prediction Of Knee Cartilage Using Statistical Shape Models, Joseph Michael Johnson Dec 2013

Analysis, Segmentation And Prediction Of Knee Cartilage Using Statistical Shape Models, Joseph Michael Johnson

Doctoral Dissertations

Osteoarthritis (OA) of the knee is one of the leading causes of chronic disability (along with the hip). Due to rising healthcare costs associated with OA, it is important to fully understand the disease and how it progresses in the knee. One symptom of knee OA is the degeneration of cartilage in the articulating knee. The cartilage pad plays a major role in painting the biomechanical picture of the knee. This work attempts to quantify the cartilage thickness of healthy male and female knees using statistical shape models (SSMs) for a deep knee bend activity. Additionally, novel cartilage segmentation from …


Reconstruction Of Patient-Specific Bone Models From X-Ray Radiography, Hatem Amin Abdel Fattah El Dakhakhni Dec 2013

Reconstruction Of Patient-Specific Bone Models From X-Ray Radiography, Hatem Amin Abdel Fattah El Dakhakhni

Doctoral Dissertations

The availability of a patient‐specific bone model has become an increasingly invaluable addition to orthopedic case evaluation and planning [1]. Utilized within a wide range of specialized visualization and analysis tools, such models provide unprecedented wealth of bone shape information previously unattainable using traditional radiographic imaging [2]. In this work, a novel bone reconstruction method from two or more x‐ray images is described. This method is superior to previous attempts in terms of accuracy and repeatability. The new technique accurately models the radiological scene in a way that eliminates the need for expensive multi‐planar radiographic imaging systems. It is also …


Angiography And Monitoring Of Hemodynamic Signals In The Brain Via Optical Coherence Tomography, Alana Mauluidy Soehartono Dec 2013

Angiography And Monitoring Of Hemodynamic Signals In The Brain Via Optical Coherence Tomography, Alana Mauluidy Soehartono

Theses and Dissertations

The brain is a complex network of interconnected neurons with each cell functioning as a nonlinear processing unit. Neural responses to stimulus can be described by activity in neurons. While blood flow changes have been associated with neural activity and are critical to brain function, this neurovascular coupling is not well understood. This work presents a technique for neurovascular interrogation, combining optogenetics and optical coherence tomography.

Optogenetics is a recently developed neuromodulation technique to control activity in the brain using light with precise spatial neuronal control and high temporal resolution. Using this method, cells act as light-gated ion channels and …


An Implantable Low Pressure Biosensor Transponder, Chad Eric Seaver Dec 2013

An Implantable Low Pressure Biosensor Transponder, Chad Eric Seaver

Masters Theses

The human body’s intracranial pressure (ICP) is a critical element in sustaining healthy blood flow to the brain while allowing adequate volume for brain tissue within the relatively rigid structure of the cranium. Disruptions in the body’s maintenance of intracranial pressure are often caused by hemorrhage, tumors, edema, or excess cerebral spinal fluid resulting in treatments that are estimated to globally cost up to approximately five billion dollars annually. A critical element in the contemporary management of acute head injury, intracranial hemorrhage, stroke, or other conditions resulting in intracranial hypertension, is the real-time monitoring of ICP. Currently such monitoring can …


Computational Modeling To Evaluate Helical Electrode Designs For Use In Vagus Nerve Stimulation, Anthony W. Cowley Jun 2013

Computational Modeling To Evaluate Helical Electrode Designs For Use In Vagus Nerve Stimulation, Anthony W. Cowley

Master's Theses

An estimated 0.5% of world’s population has been diagnosed with epilepsy. Of these patients 20-30% will be unable to achieve seizure control with anti-epileptic drugs. Vagus nerve stimulation (VNS) may be an appropriate treatment option for some patients with pharmaceutically refractory, partial-onset seizures.

VNS therapy uses a helical electrode to interface between the implantable pulse generator and the vagus nerve. While there have been several studies related to the mechanical and electrical safety of such electrodes, little work has been done toward understanding the effectiveness of the helical electrode in nerve stimulation. A better understanding of the voltage field and …


Design And Implementation Of Wireless Point-Of-Care Health Monitoring Systems: Diagnosis For Sleep Disorders And Cardiovascular Diseases, Se Chang Oh May 2013

Design And Implementation Of Wireless Point-Of-Care Health Monitoring Systems: Diagnosis For Sleep Disorders And Cardiovascular Diseases, Se Chang Oh

Graduate Theses and Dissertations

Chronic sleep disorders are present in 40 million people in the United States. More than 25 million people remain undiagnosed and untreated, which accounts for over $22 billion in unnecessary healthcare costs. In addition, another major chronic disease is the heart diseases which cause 23.8% of the deaths in the United States. Thus, there is a need for a low cost, reliable, and ubiquitous patient monitoring system. A remote point-of-care system can satisfy this need by providing real time monitoring of the patient's health condition at remote places. However, the currently available POC systems have some drawbacks; the fixed number …


Design And Testing Of Novel Mouthguard With Intermediate Nitinol And Foam Layers, Adam Kessler May 2013

Design And Testing Of Novel Mouthguard With Intermediate Nitinol And Foam Layers, Adam Kessler

UNLV Theses, Dissertations, Professional Papers, and Capstones

It is the aim of this study to investigate a novel mouthguard design that incorporates the use of a nickel-titanium (Nitinol) layer and thin foam layer in addition to EVA layers. It is thought that the Nitinol layer can distribute the force of an impact and that the thin foam layer may absorb this distributed force better than a solid EVA mouthguard of the same thickness. Rectangular, flat coupons representative of several mouthguard configurations were constructed for testing using an instrumented drop-weight impact tower. The coupon configurations include a control made of laminated EVA, a group of laminated EVA and …


Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead May 2013

Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead

UNLV Theses, Dissertations, Professional Papers, and Capstones

The goal of this research is to provide a framework for the integration of tube type, cylindrical Ionic Polymer Metal-Composite (IPMC) into conventional devices. IPMCs are one of the most widely used types of electro-active polymer actuator, due to their low electric driving potential and large deformation range. For this research a tube type IPMC was investigated. This IPMC has a circular cross section with four separate electrodes on its surface and a hole through the middle. The four electrodes allow for biaxial bending and accurate control of the tip location. One of the main advantages of using this type …


Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao Jan 2013

Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao

Theses and Dissertations--Electrical and Computer Engineering

In immersive audio environments with distributed microphones, Independent Component Analysis (ICA) can be applied to uncover signals from a mixture of other signals and noise, such as in a cocktail party recording. ICA algorithms have been developed for instantaneous source mixtures and convolutional source mixtures. While ICA for instantaneous mixtures works when no delays exist between the signals in each mixture, distributed microphone recordings typically result various delays of the signals over the recorded channels. The convolutive ICA algorithm should account for delays; however, it requires many parameters to be set and often has stability issues. This thesis introduces the …


A Biocompatible Sic Rf Antenna For In-Vivo Sensing Applications, Shamima Afroz Jan 2013

A Biocompatible Sic Rf Antenna For In-Vivo Sensing Applications, Shamima Afroz

USF Tampa Graduate Theses and Dissertations

A continuous glucose sensor employing radio frequency (RF) signals is presented using the biocompatible material Silicon Carbide (SiC). Unlike biosensors that require direct contact with interstitial fluids to trigger chemical reactions to operate, this biocompatible SiC sensor does not require a direct interface. The sensing mechanism for this SiC sensor is based upon a shift in resonant frequency, as a function of change in glucose levels, which electrically manifests itself as a change in blood permittivity and

conductivity. For in vivo applications the antenna sensor needs to operate inside the body environment, and it has been found that the best …


Vapor-Liquid-Solid(Vls) Grown Silica (Siox) Nanowires As The Interface For Biorecognition Molecules In Biosensors, Eduardo Murphy-Pérez Jan 2013

Vapor-Liquid-Solid(Vls) Grown Silica (Siox) Nanowires As The Interface For Biorecognition Molecules In Biosensors, Eduardo Murphy-Pérez

USF Tampa Graduate Theses and Dissertations

SiOx nanowires grown through the VLS mechanism were electrophoretically deposited on top of Au electrodes. GOx was immobilized using APTES and the EDC-NHS chemistry. Cyclic Voltammetry was used as the method to characterize the electrodes through their processing steps, and CV was also used to detect glucose in a PBS based solution. Ferro-Ferri Cyanide couple was used as the mediator.


Myoglobin Detection On Sic: Immunosensor Development For Myocardial Infarction, Alexandra Oliveros Villalba Jan 2013

Myoglobin Detection On Sic: Immunosensor Development For Myocardial Infarction, Alexandra Oliveros Villalba

USF Tampa Graduate Theses and Dissertations

Silicon carbide (SiC) has been around for more than 100 years as an industrial material and has found wide and varied applications because of its unique electrical and thermal properties. In recent years there has been increased attention on SiC as a viable material for biomedical applications. Among these applications are those where SiC is used as a substrate material for biosensors and biotransducers, taking advantage of its surface chemical, tribological and electrical properties.

In this work we have used the proven bio- and hema-compatibility of SiC to develop a viable biorecognition interface using SiC as the substrate material for …