Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran Jun 2013

Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran

Biomedical Engineering

Ankle injuries have always posed an issue to a number of athletes. Sports that involve running and jumping accumulate about 25% of injuries correlating to ankle sprains. In most ankle sprains the inversion (supination) of the ankle cause damage to lateral ligaments. The two most common lateral ligaments to experience damage are the anterior talofibular (ATFL) and calcaneofibular (CFL) ligaments. The methods of taping and ankle braces have allowed athletes to prevent recurring sprains from occurring. However, sprains can still occur even when one or both methods are applied. The purpose of each method is to restrict the range of …


Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges Jun 2013

Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges

Biomedical Engineering

Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …


A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll Mar 2013

A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll

Biomedical Engineering

Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …