Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

2012

Medicine and Health Sciences

Theses/Dissertations

Institution
Keyword
Publication

Articles 1 - 18 of 18

Full-Text Articles in Biomedical Engineering and Bioengineering

Properties And Applications Of Sensory Outcome Measures In Carpal Tunnel Syndrome, Derek Km Cheung Dec 2012

Properties And Applications Of Sensory Outcome Measures In Carpal Tunnel Syndrome, Derek Km Cheung

Electronic Thesis and Dissertation Repository

This thesis aimed to determine the psychometric properties and applications of sensory threshold tools and outcome measures in patients with Carpal Tunnel Syndrome (CTS). The first chapter is a psychometric study that defines clinically important difference (CID), construct validity and responsiveness of touch and vibration threshold tools and in the Symptoms Severity Scale (SSS). The study found the CID for the PSSD and for the SSS was 0.15g/mm2 and 0.50 respectively. The study also found that the Vibrometer was more representative of hand function and responsive compared PSSD. The second objective of this thesis was to determine the feasibility …


The Design And Testing Of A Solar Autoclave With Broad Spectrum Sterilization Capabilities, Sarah S. Trabia Nov 2012

The Design And Testing Of A Solar Autoclave With Broad Spectrum Sterilization Capabilities, Sarah S. Trabia

Honors College Theses

Energy is difficult to come by in developing countries and this interferes with the ability of doctors to provide good healthcare to their patients. Without decent sterilization, patients can become infected and diseases can spread throughout hospitals. This study involves designing a solar autoclave for developing countries that is as efficient as electrical autoclaves. The design is intended to not require any electrical input and to be affordable to those who cannot afford advanced medical equipment. Once the solar autoclave is designed, it will be tested to determine if it can sterilize equipment against a variety of different bacteria, including …


Real-Time Analysis Of Brain Tumor Cell Dynamics: Novel Thermoelectric Detection Of L-Glutamate And Cell Metabolism Using Microfluidics, Siva Mahesh Tangutooru Oct 2012

Real-Time Analysis Of Brain Tumor Cell Dynamics: Novel Thermoelectric Detection Of L-Glutamate And Cell Metabolism Using Microfluidics, Siva Mahesh Tangutooru

Doctoral Dissertations

This study describes the design, fabrication and applications of a novel thermoelectric microfluidic bio-sensor. The bio-sensor is used for real time detection of the L-glutamate (L-glu) dynamics and metabolism for brain tumor cells immobilized in a microfluidic device. The microfluidic device is fabricated using a polymer/glass laminating technique (Xurography). An antimony-bismuth thin-film thermopile (primary sensing element) is integrated to the microfluidic device. The brain tumor cells are immobilized over the thermopile covering measuring and reference junctions of the thermopile using a poly-l-lysine coating layer. L-glutamate oxidase (L-GLOD) is immobilized over the measuring junctions of the thermopile prior to the immobilization …


Augmented Image-Guidance For Transcatheter Aortic Valve Implantation, Pencilla Lang Jul 2012

Augmented Image-Guidance For Transcatheter Aortic Valve Implantation, Pencilla Lang

Electronic Thesis and Dissertation Repository

The introduction of transcatheter aortic valve implantation (TAVI), an innovative stent-based technique for delivery of a bioprosthetic valve, has resulted in a paradigm shift in treatment options for elderly patients with aortic stenosis. While there have been major advancements in valve design and access routes, TAVI still relies largely on single-plane fluoroscopy for intraoperative navigation and guidance, which provides only gross imaging of anatomical structures. Inadequate imaging leading to suboptimal valve positioning contributes to many of the early complications experienced by TAVI patients, including valve embolism, coronary ostia obstruction, paravalvular leak, heart block, and secondary nephrotoxicity from contrast use.

A …


Development And Validation Methodology Of The Nuss Procedure Surgical Planner, Krzysztof J. Rechowicz Jul 2012

Development And Validation Methodology Of The Nuss Procedure Surgical Planner, Krzysztof J. Rechowicz

Computational Modeling & Simulation Engineering Theses & Dissertations

Pectus excavatum (PE) is a congenital chest wall deformity which is characterized, in most cases, by a deep depression of the sternum. A minimally invasive technique for the repair of PE (MIRPE), often referred to as the Nuss procedure, has been proven to be more advantageous than many other PE treatment techniques. The Nuss procedure consists of placement of a metal bar(s) underneath the sternum, thereby forcibly changing the geometry of the ribcage. Because of the prevalence of PE and the popularity of the Nuss procedure, the demand to perform this surgery is greater than ever. Therefore, a Nuss procedure …


Evaluation Of Autonomous Robotic Milling Methodology For Natural Tooth-Shaped Implants Based On Sko Optimization, Yongki Yoon Jul 2012

Evaluation Of Autonomous Robotic Milling Methodology For Natural Tooth-Shaped Implants Based On Sko Optimization, Yongki Yoon

Mechanical & Aerospace Engineering Theses & Dissertations

Robotic surgery is one of the most demanding and challenging applications in the field of automatic control. One of the conventional surgeries, the dental implantation, is the standard methodology to place the artificial tooth root composed of titanium material into the upper or lower jawbone. During the dental implant surgery, mechanical removal of the bone material is the most critical procedure because it may affect the patient's safety including damage to the mandibular canal nerve and/or piercing the maxillary sinus. With this problem, even though short term survival rates are greater than 95%, long term success rate of the surgery …


Development Of A Protocol To Measure Gene Expression In The Mouse Tibia, Daniel Hoover Jun 2012

Development Of A Protocol To Measure Gene Expression In The Mouse Tibia, Daniel Hoover

Biomedical Engineering

Numerous molecular factors active in bone tissue direct fracture repair and remodeling which can be altered by disease conditions such as Peripheral Arterial Disease (PAD) and Osteoporosis. Methods of molecular biology are commonly applied to investigate the expression and role of these molecular factors. This project presents a robust three-step protocol for examining gene expression in the mouse tibia. The protocol begins with isolating RNA from a flash frozen tibia sample. The isolated RNA is reverse transcribed into cDNA. Finally, PCR is performed to indentify expressed genes. Establishing this protocol will allow further research into the mechanisms of bone remodeling …


Esem Analysis Of Mice Femurs With Varying Sost Levels, Patrick K. Mcclay Jun 2012

Esem Analysis Of Mice Femurs With Varying Sost Levels, Patrick K. Mcclay

Biomedical Engineering

This project’s goal was to analyze the properties of the cortical femur on 100 mice bones from Lawrence Livermore National Laboratory. Analysis was limited to imaging which determined the ratio of bone volume to total volume (BV/TV) and osteocyte lacunae density. Mice were altered to knock out their SOST gene: a negative regulator of bone formation. Twelve groups were created to differentiate their treatment, duration, and phenotype. Transgenic (TG) mice had an overexpression of the SOST gene: they carried a bacterial artificial chromosome. Mice with limb defects (DEF) were the offspring of two TG mice and carried twice the amount …


Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall May 2012

Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall

Electronic Thesis and Dissertation Repository

The hybridization of magnetic resonance imaging (MRI) with positron emission tomography (PET) or single photon emission computed tomography (SPECT) enables the collection of an assortment of biological data in spatial and temporal register. However, both PET and SPECT are subject to photon attenuation, a process that degrades image quality and precludes quantification. To correct for the effects of attenuation, the spatial distribution of linear attenuation coefficients (μ-coefficients) within and about the patient must be available. Unfortunately, extracting μ-coefficients from MRI is non-trivial. In this thesis, I explore the problem of MRI-based attenuation correction (AC) in emission tomography.

In particular, I …


Aptamer-Based Spr Biosensor For Detection Of Avian Influenza Virus, Hua Bai May 2012

Aptamer-Based Spr Biosensor For Detection Of Avian Influenza Virus, Hua Bai

Graduate Theses and Dissertations

Rapid and specific detection of avian influenza (AI) virus is urgently needed with the concerns over the outbreaks of highly pathogenic H5N1 avian influenza in animal and human infection. Aptamers are artificial oligonucleic acid that can specifically bind to target molecules. They show comparable affinity for target virus and better thermal stability than monoclonal antibodies. Those advantages make aptamers promising candidates in diagnostic and detection applications. The goal of this research was to use DNA&ndashaptamer as the specific recognition element in a portable surface plasmon resonance (SPR) biosensor for detection of AI H5N1 virus in poultry.

A SPR biosensor was …


Development Of A Microfluidic Device Coupled To Microdialysis Sampling For The Pre-Concentration Of Cytokines, Randy Francisco Espinal Cabrera May 2012

Development Of A Microfluidic Device Coupled To Microdialysis Sampling For The Pre-Concentration Of Cytokines, Randy Francisco Espinal Cabrera

Graduate Theses and Dissertations

A proof-of-concept microfluidic device combined with heparin-immobilized magnetic beads was created to concentrate cytokine proteins collected from microdialysis samples. Cytokines are known to be related to several diseases such as cancer, and Parkinson's diseases, so to be able to develop more effective diseases treatments their interactions have to be well understood. Amine-functionalized polystyrene and carboxyl-functionalized magnetic microspheres of ~6.0 ìm in diameter were used to immobilize heparin. The amount of heparin immobilized on polystyrene beads was 5.82 x 10-8 ± 0.36 x 10-8 M per 1.0 x 106 beads and for magnetic beads was 0.64 x 10-8 ± 0.01 x …


Novel Phantoms And Post-Processing For Diffusion Spectrum Imaging, Vaibhav Juneja May 2012

Novel Phantoms And Post-Processing For Diffusion Spectrum Imaging, Vaibhav Juneja

Dissertations & Theses (Open Access)

High Angular Resolution Diffusion Imaging (HARDI) techniques, including Diffusion Spectrum Imaging (DSI), have been proposed to resolve crossing and other complex fiber architecture in the human brain white matter. In these methods, directional information of diffusion is inferred from the peaks in the orientation distribution function (ODF). Extensive studies using histology on macaque brain, cat cerebellum, rat hippocampus and optic tracts, and bovine tongue are qualitatively in agreement with the DSI-derived ODFs and tractography. However, there are only two studies in the literature which validated the DSI results using physical phantoms and both these studies were not performed on a …


The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink May 2012

The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink

UNLV Theses, Dissertations, Professional Papers, and Capstones

Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …


Encapsulation And Controlled Release Of Rhu-Erythropoietin From Chitosan Biopolymer Nanoparticles, Cody Bulmer Apr 2012

Encapsulation And Controlled Release Of Rhu-Erythropoietin From Chitosan Biopolymer Nanoparticles, Cody Bulmer

Electronic Thesis and Dissertation Repository

The objective of this research project was to develop a drug delivery system for recombinant human erythropoietin (rHu-EPO), a glycoprotein hormone used in the treatment of renal anaemia and chemotherapy induced anaemia, using the biopolymer chitosan as the base component. Two types of chitosan nanoparticles were produced through ionotropic gelation using flush mixing with either tripolyphosphate (TPP) or carrageenan polymer. Chitosan-TPP and chitosan-carrageenan nanoparticles were generated under a variety of conditions to evaluate the effects of chitosan concentration, chitosan to anion mass ratio and solution pH on the nanoparticle characteristics of particle diameter, surface charge and particle size distribution. A …


Synergistic Effect Of Subnanosecond Pulsed Electric Fields And Temperature On The Viability Of Biological Cells, James Thomas Camp Apr 2012

Synergistic Effect Of Subnanosecond Pulsed Electric Fields And Temperature On The Viability Of Biological Cells, James Thomas Camp

Electrical & Computer Engineering Theses & Dissertations

Pulsed electric fields have been used to induce a biological response in cells, and at sufficient energy, can cause cell death. By reducing the pulse duration from presently used nanosecond to subnanosecond ranges, the electric field can be delivered to biological tissue non-invasively by the use of an antenna instead of electrodes, such as needles. Studies have previously been completed in which the aim was to determine the energy density (electric field strength, number of pulses) required to induce cell death with 800 ps pulses. Based on this data, it was concluded that for pulse durations of 200 ps, with …


Evaluation Of Transfer Technologies To Preserve Shoulder Function In Sci, Karen Michelle Mann Mar 2012

Evaluation Of Transfer Technologies To Preserve Shoulder Function In Sci, Karen Michelle Mann

USF Tampa Graduate Theses and Dissertations

This study investigated a series of independent unassisted and device-assisted transfers from a wheelchair to vehicle mock-up and vice versa while simultaneously capturing kinematic, kinetic and electromyographic (EMG) data of impaired volunteers. The study provides a venue for observation and evaluation of upper extremity (UE) joint stresses, muscular force and functional demands associated with transfers in persons with spinal cord injury (SCI) to ultimately prevent UE injury, minimize excessive stress, preserve functionality and limit pain. If people with SCI lose function of their UEs, due to pain and/or degeneration, they must then rely on others for everyday tasks.

Five paraplegic …


Noninvasive Assessment And Modeling Of Diabetic Cardiovascular Autonomic Neuropathy, Siqi Wang Jan 2012

Noninvasive Assessment And Modeling Of Diabetic Cardiovascular Autonomic Neuropathy, Siqi Wang

Theses and Dissertations--Biomedical Engineering

Noninvasive assessment of diabetic cardiovascular autonomic neuropathy (AN): Cardiac and vascular dysfunctions resulting from AN are complications of diabetes, often undiagnosed. Our objectives were to: 1) determine sympathetic and parasympathetic components of compromised blood pressure regulation in patients with polyneuropathy, and 2) rank noninvasive indexes for their sensitivity in diagnosing AN. Continuous 12-lead electrocardiography (ECG), blood pressure (BP), respiration, regional blood flow and bio-impedance were recorded from 12 able-bodied subjects (AB), 7 diabetics without (D0), 7 with possible (D1) and 8 with definite polyneuropathy (D2), during 10 minutes supine control, 30 minutes 70-degree head-up tilt and 5 minutes supine recovery. …


Development Of A Bi-Directional Electronics Platform For Advanced Neural Applications, Luca Abbati Jan 2012

Development Of A Bi-Directional Electronics Platform For Advanced Neural Applications, Luca Abbati

USF Tampa Graduate Theses and Dissertations

This work presents a high-voltage, high-precision bi-directional multi-channel system capable of stimulating neural activity through bi-phasic pulses of amplitude up to ∓50 V while recording very low-voltage responses as low as tens of microvolts. Most of the systems reported from the scientific community possess at least one of the following common limitations: low stimulation voltages, low gain capabilities, or insufficient bandwidth to acquire a wide range of different neural activities.

While systems can be found that present remarkable capabilities in one or more specific areas, a versatile system that performs over all these aspects is missing. Moreover, as many novel …