Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

Multimodal Noncontact Diffuse Optical Reflectance Imaging Of Blood Flow And Fluorescence Contrasts, Daniel Irwin Jan 2018

Multimodal Noncontact Diffuse Optical Reflectance Imaging Of Blood Flow And Fluorescence Contrasts, Daniel Irwin

Theses and Dissertations--Biomedical Engineering

In this study we design a succession of three increasingly adept diffuse optical devices towards the simultaneous 3D imaging of blood flow and fluorescence contrasts in relatively deep tissues. These metrics together can provide future insights into the relationship between blood flow distributions and fluorescent or fluorescently tagged agents. A noncontact diffuse correlation tomography (ncDCT) device was firstly developed to recover flow by mechanically scanning a lens-based apparatus across the sample. The novel flow reconstruction technique and measuring boundary curvature were advanced in tandem. The establishment of CCD camera detection with a high sampling density and flow recovery by speckle …


Development Of A Blood Flow Measurement Protocol Using Particle Image Velocimetry, Jennifer Chi-Ying Go Jun 2012

Development Of A Blood Flow Measurement Protocol Using Particle Image Velocimetry, Jennifer Chi-Ying Go

Biomedical Engineering

Peripheral Arterial Occlusive Disease (PAOD) is an acquired inflammatory disease where a peripheral artery becomes occluded due to the buildup of atherosclerotic plaques. In patients that possess collateral arteries, an occlusion can lead to shear induced outward remodeling, arteriogenesis, of these collaterals, partially restoring blood flow. However, newly remodeled collaterals exhibit reduced functional vasodilation, which may impair normal activity, such as ambulation. To model chronic ischemia and arteriogenesis in collaterals, a femoral artery ligation in a murine hindlimb is commonly performed. Previous efforts by our group involved measurements of collateral artery diameter to assess the impact of arteriogenesis on functional …


Influence Of Tissue Absorption And Scattering On Diffuse Correlation Spectroscopy Blood Flow Measurements, Daniel Irwin Jan 2011

Influence Of Tissue Absorption And Scattering On Diffuse Correlation Spectroscopy Blood Flow Measurements, Daniel Irwin

University of Kentucky Master's Theses

This investigation evaluates the influences of optical property assumptions on nearinfrared diffuse correlation spectroscopy (DCS) flow index measurements. Independent variation is induced in optical properties, absorption coefficient (μa) and reduced scattering coefficient (μs’), of liquid phantoms with concurrent measurements of flow indices. A hybrid instrument is incorporated consisting of a dual-wavelength (785 and 830 nm) DCS flow device to obtain flow indices and a frequency-domain tissue-oximeter for optical properties. Flow indices are calculated with measured μa and μs’ or assumed constant μa and μs’. Inaccurate μs’ assumptions produced …